Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

12/27/2004

Applicant:

BRUCKMEIER WALTER A & MARY C JT/RS

Description:

COMPLAINT:MIN HOUSING-HEATER NOT WORKING IT'S CRACKED. BACK WINDOW NEEDS TO BE REPLACED. CAULKING HAS ROTTED OFF.

Outstanding Inspections

Case Number: T04DV00988
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
NPO(PL)-GAS SUPPLY/CONNECT None Not Inspected
VIOL(PL) - FIXTURES None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
NPO - SMOKE ALARMS None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00988
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/06/2005 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE, MET WITH TENANTS MOTHER BETTY DAVIS, MRS. DAVIS STATED COLD AIR COMING THROUGH GLASS DOUBLE DOORS, DOOR WERE FOUND WITH GAPS & COVERED WITH PLASTIC MATERIAL, MRS. DAVIS THEN PROCIDED TO FURNACE & STATED HER DAUGHTER HAD SOMEONE CHECK FURNACE & STATED HEAT EXCHANGER WAS CRACKED & S.W. GAS SERVICE DECIDED NOT TO TURN ON DUE TO UNKNOWN PROBLEM, REQUESTED PAPER WORK FROM ELECTRICAL PERSON & HEATING CONTRACTOR. MRS. DAVIS STATED HER DAUGHTER DIDN'T LEAVE PAPER WORK BUT WOULD FOWARD PAPER WORK WHEN SHE RETURNS. MRS. DAVIS DID FIND COPY OF PAPER WORK FROM TOTAL FACILITY MAINTENANCE & ALLOWED D.N.R. INSP. TO KEEP FOR FILES. MRS. DAVIS DID STATE DAUGHTER WILL BE MOVING OUT DUE TO OWNER INFORMED HER WORK COULD NOT BE PERFORMED WHILE TENANT WAS IN UNIT. MECH: (1) HEATER VENTS HAVE BEEN BLOCKED OFF BY TENANT, MRS. DAVIS STATED DAUGHTER BLOCKED OFF DUE TO COLD AIR COMING INN IN LIVING ROOM & BEDROOM SOUTHEAST SIDE. ACCESS CONTROL: 1) DINING AREA WINDOW HARD TO OPEN DUE TO PAINT, MRS. DAVIS WHEN ASKED WHO PAINTED REPLIED TENANT PAINTED WINDOWS. OWNER WAS ASKED & TENANT WAS GIVEN APPROVAL, BUT OWNER REQUESTED FOR NO PAINT TO BE REMOVED. 2) LIVING ROOM WINDOW HARD TO OPEN DUE TO PAINT AS WELL AS BEDROOM WINDOW. 3) NORTHEAST BEDROOM WINDOWS HAVE REBAR AS WINDOW GRATE & LACKING PANIC HARDWARE AS WELL AS S.E. BEDROOM. HEATING: 1) FURNACE LACKING SERVICE, FOUND LARGE AMOUNTS OF RUST PARTICLES, APPEARS NEW TRANSFORMER & LIMIT SWITCH WERE INSTALLED. FURNACE FLOOR LACKING REQUIRED SHEET METAL COVER & RETURN AIR CONNECTION NOT SEALED AT FURNACE FLOOR. INTERIOR FEATURES: 1) NORTHEAST BEDROOM WALL HAS BEEN PATCHED & REQUIRED TO BE FINISHED. 2) SOUTHEAST BEDROOM CEILING HAS SECTION OF TEXTURE PEELING OFF APPROX. 18''X18''. ELECTRICAL: 1) APPEARS ALTERATION HAVE BEEN DONE TO ORIGINAL ELECTRICAL SYSTEM, GFIC WERE FOUND LACKING IN KITCHEN AREA. 2) RECEP. - IN KITCHEN SINK AREA HAS NEUTRAL (ADDED) FOR EQUIPMENT GR. NO PROTECTION WILL CHECK IF REQUIRED. 3) NORTHEAST BEDROOM RECEPTACLE ON WEST WALL LACKING EQUIPMENT GR. 4) BATHROOM LIGHT FIXTURE HAS UNGROUNDED RECEPTACLE WILL BE REQUIRED TO BE REMOVED. 5) DRYER RECEPTACLE IS 50 AMPS- REQUIRES TO BE 30 AMP. 6) LOOSE DRYER BOX, BOX NOT PROPERLY SECURED TO WALL. FIRE CONTROL: 1) STRUCTURE DOSE HAVE SMOKE DETECTORS BUT HAVE BEEN MADE INOPERABLE BY PULLING BATTERIES ARE FROM CONTACT POINTS. NO WORKING SMOKE DETECTOR. SMOKE DETECTOR REMOVED IN SOUTHEAST BEDROOM. PLUMBING: 1) TOILET FOUND LEAKING MAY BE FLAPPER. 2) BATHROOM SINK FAUCET FOUND LEAKING. CONTACTED TONY AT TOTAL FACILITY MAINTENANCE, INQUIRED IF THEY HAD A C-11 OR L-11 LICENSE FOR ELECTRICAL REPAIRS, TONY REPLIED THEY WERE ALLOWED TO DO ELECTRICAL REPAIRS UP TO 750.00 BUT DIDN'T HAVE C-11 OR L-11 LICENSE. PICTURES WERE TAKEN.
02/23/2005 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE ON FW/UP INSPECTION, MET WITH OWNER & WENT OVER VIOLATION LISTED ON N.O.V. ISSUED ON 1/12/05. (1) TC-16-11 BUILDING INTERIOR (A) FIRE SAFETY: 1) ABATED, ALL WINDOWS HAVE BEEN REPAIRED & OPEN & CLOSE PROPERLY. 2) ABATED, ALL SMOKE DETECTORS WERE CHECKED & WORKING. (2) TC-16-11 ELECTRICAL SYSTEM 16-4 PERMITS REQUIRED: 1) NOT ABATED - WORK HAS BEEN SCHEDULED. 2) ABATED -LIGHT FIXTURE IN VIOLATION HAS BEEN REMOVED. 3) ABATED -REPAIRS WERE MADE TO RECEPTACLE & CHECKED FOR EQUIPMENT GROUND. NO GROUND WAS CORRECTED. 4) INVALID - OVER SIGHT BY INSPECTOR, 30 AMP RECEPTACLE DOSE MATCH 30 AMP BREAKER. 5) ABATED - DRYER BOX RESECURED TO WALL. (3) TC. 16-11 (E) PLUMBING SYS. 1) ABATED - NEW FLAPPER INSTALLED. 2) ABATED - NEW GASKETS & SEAT INSTALLED FOR STEMS. (4) TC-16-11 (F) INTERIOR FEATURES: 1) NOT ABATED, WORK IS ONGOING. 2) NOT ABATED, WORK IS ONGOING. HAND-DELIVERED NOTICE FOR LACK OF HEATING VIOLAITON WAS NOT IN PACKET. NOTICE WAS HAND-DELIVERED & SIGNED BY OWNER. 5 DAYS WERE GIVEN TO ABATE VIOLATION. OWNER HAD HEATING CONTRACTOR INSTALL NEW FURNACE W/ GAS VALVE, FLEX CONNECTION, NEW METAL FLOORING & FLUE SYSTEM. COULD NOT TEST DUE TO TENANT HAD SHUT OFF GAS SERVICE. OWNER WILL CONTACT CONTRACTOR & HAVE GAS SERVICE TURNED BACK ON TO COMPLETE & TEST BY D.S.D. FOR FINAL OF PERMIT. OWNER MAKING GOOD PROGRESS. WILL EXTEND ABATEMENT PERIOD 30 DAYS, PICTURES WERE TAKEN.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00988
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
01/21/2005 CONTACTED BY PHONE
03/03/2005 CONTACTED IN PERSON
01/14/2005 NOTICE OF VIOLATION ISSUED
01/14/2005 COURT ORDERED ABATEMENT
03/15/2006 VIOLATION CLOSED