Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/13/2004

Applicant:

SLILATY ABRAHAM

Description:

COMPLAINT:MIN HOUSING-ROOF LEAKING IN KTICHEN, LIVING ROOM DININGROOM.

Outstanding Inspections

Case Number: T04DV00971
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 13
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - LIVING AREAS None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(PL)-SEWAGE DISPOSAL (SYS) None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - EGRESS None Not Inspected
NPO - SMOKE ALARMS None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00971
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
04/29/2005 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE TENANT FILING COMPLAINT, NO LONGER IN UNIT, MADE CONTACT WITH MANAGER, BILL & STATED NEW TENANT HAS DONE MANY REPAIRS TO INTERIOR & EXTERIOR, NEW PAINT THROUGHOUT & NEW ROOF, INSTALLED CEILING IN KITCHEN BUT LACKS FINISHING. DID FIND MIN-HOUSING ISSUES & ARE AS FOLLOWS ELECTRICAL; 1) MAIN SYSTEM HAS BEEN UP-GRADED ALONG WITH INTERIOR CIRCUT. INTERIOR CIRCUTS & ALL TESTED CORRECTLY. ALL EXTERIOR CONNECTIONS ARE WEATHER TIGHT. CHECK FOR PERMITS. 2) DID FIND DOUBLE LUGGING IN DISCONNECT BOX 3) ILLEGAL SPLICED ELECTRICAL CONDUCTOR FOR HWH 4) G.F.I.C. LACKING FOR KITCHEN WEATHER PROOFING; 1) BACK DOOR LACKS WEATHER STRIPPING 2) BROKEN & BOARDED UP WINDOW ON EASTSIDE ACCESS CONTROL; 1) DOUBLED KEYED DEAD BOLT ON BACK DOOR. PLUMBING; 1) MODIFICATION TO VENT SYSTEM, PICTURES WERE TAKEN. FIRE SAFETY; 1) LACK REQUIRED SMOKE DETECTORS. NOV TO BE ISSUED AFTER RESEARCH FOR ELECTRICAL UPGRADE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00971
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
12/21/2005 NOTICE OF VIOLATION ISSUED
03/17/2009 VANS - DEMOLITION BY OWNER