Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

11/18/2004

Applicant:

LEON JUVENTINO R TR

Description:

COMPLAINT RE: MIN HOUSING-HEAT HAS NOT BEEN TURNED ON. DID REQUEST OWNER TO TURN ON HEAT A MONTH AGO. FRONT DOOR WINDOW IS SHATTERED & DOOR DOES NOT PROPERLY SECURE. TENANT HAS CHILD UNDER 2 YRS IN THE HOME.

Outstanding Inspections

Case Number: T04DV00912
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
11/24/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Correction Required VISITED SITE ON INITIAL INSPECTION. PROPERTY CONTAINS 2 STRUCTURES AND 2 TRAILERS. INSEPCTION WAS DONE ON ADDRESS 6416 TRAVEL TRAILER. MIN HOUSING ARE AS FOLLOWS: ELECTRICAL 1. EXPOSED ELECTRICAL CONDUCTORS FOR COOLER NOT IN CONDUIT ROMEX CORD HAS BEEN ALTERED AND THREE PRONG INSTALLED ON END. 2. EXPOSED ELECTRICAL JUNCTION BOX BACK COVER PLATE ON NORTH SIDE. 3. HAZARDOUS ELECTRICAL, ELECTRICAL DISCONNECT LACKING DEAD PLATE COVER. ADDITION ELECTRICAL CIRCUITS HAVE BEEN ADDED THROUGHOUT TRAVEL TRAILER BY USE OF UNAPPROVED PVC PIPING. 4. ELECTRICAL PEDISTAL SUPPORT POST IN MADE OF WOOD AND IS NOT UNACCEPTABLE PEDISTAL. (NOT TERMITE PROOF) 5. TRAVEL TRAILER INTERIOR RECEPTACLE CONSIST OF TWO PRONG THAT ARE ORIGINAL EQUIPMENT AND ALSO 3 PRONG RECEPTACLE, 3 PRONG RECEPTACLE ARE LACKING MECHANICAL GROUNDS. 6. ADDITION OF ELECTRICAL CIRCUIT IN BOTH ROOM EXPOSED ROMEX AND PLASTIC J-BOX NOT INSTALLED IN WALL, SOME 2 PRONG RECEPTACLE PULLING AWAY FROM WALL. 7. RANGE HOOD HAS BEEN CONNECTED TO POWER BY USE OF APPLIANCE CONDITION AND PLUGGED INTO WALL RECEPTACLE, NO GFIC IN KITCHEN AND BATHROOM. WEATHERPROOFING 1. SEVERAL BOKEN WINDOW THROUGHOUT TRAILER. 2. BOTH ENTRY DOOR LACKING WEATHERSTRIPPING, TENANT HAS INSTALLED ALUMINIUM TAPE TO SEAL OPENING IN ONE DOOR AND STICKS TOWELS UNDER OTHER DOOR FOR WEATHER PROTECTION. ACCESS CONTROL/FIRE SAFETY 1. HASP AND PADLOCK INSTALLED ILLEGALLY ON 1 ENTRY DOOR. 2. TRAILER LACKING WORKING SMOKE DETECTOR 3. TRILER LACKING HAND RAIL. COOLING 1. DUCT WORK IS MADE OF WOOD AND STAND IS MADE OF 2" X 4" MATERIAL BOTH ARE NOT ACCEPTABLE METHOD OF INSTALLATION FOR COOLING EQUIPMENT. PLUMBING 1. GAS FLEX LINE IS LONGER THAN 3 FEET, EXIST LINE IS CRACKED. 2. COPPER LINE HAVE BEEN ADDED AND LACKING WEATHER PROTECTION. 3. ABS HAS BEEN ADDED FOR WASHING MACHINE ALONG W/COPPER LINE FOR WATER SUPPLY. 4. BATHROOM SINK IS CLOGGED. HEATING 1. TRAILER LACKING PERMANENT HEATING APPLAINCE, HEAT IS BEING SUPPLIED BY 2 SMALL SPACE HEATERS PROVIDED BY TENANT. NOV WAS ISSUED FOR LACK OF PERMANENT HEATING APPLIANCE AND TRAVEL TRAILER LACKING WORKING SMOKE DETECTOR, 15 DAYS WERE GIVEN TO INSTALL ORIGINAL TYPE HEATING AND MUST PASS INSPECTION BY MECHANICAL INSPECTOR. AMENDED NOV WILL BE ISSUED WHEN RESEARCH IS DONE ON PENDING VIOLATION. NOV WAS POSTED AND PICTURES WERE TAKEN.
12/21/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE, STRUCTURE IS VACANT & SECURED AT THIS TIME. HAVE BEEN CONTACTED BY OWNER AND HE STATED TENANT WAS RELEASED FROM LEASE & WILL NO LONGER RENT UNIT. CALLED RECEIVED ON 12/ /04. RESEARCH HAS NOT BEEN COMPLETED, N.O.V. IS PENDING. ZONING WILL BE CONTACTED TO SEE IF PROPERTY IS ZONED FOR TRAILERS. D.S.D. RECORDS WILL BE CHECKED FOR ELECTRICAL & PLUMBING ISSUES AS WELL AS PIMA COUNTY WASTE WATER. DO FW/UP IN 30 DAYS.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00912
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
12/06/2004 CONTACTED BY PHONE
01/20/2005 CONTACTED IN PERSON
12/07/2004 NOTICE OF VIOLATION ISSUED
12/14/2004 COURT ORDERED ABATEMENT
03/15/2006 VIOLATION CLOSED