Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T04DV00911
Case Details
Entered Date:
11/17/2004
Applicant:
HOLGUIN JOSE & JOSEFA REVOC TRUST
Description:
COMPLAINT:MIN HOUSING- SEVERAL ISSUES.
Outstanding Inspections
Case Number: T04DV00911
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected | ||
NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
VIOL(EL) - CIRCUITS | None | Not Inspected | ||
VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
NPO(PL)-WATER HEATERS | None | Not Inspected | ||
NPO(HC)-HEATING & VENTILATION | None | Not Inspected | ||
VIOL(SA) - BATHS | None | Not Inspected | ||
VIOL(SA) - KITCHEN | None | Not Inspected | ||
NPO - SMOKE ALARMS | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T04DV00911
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/17/2004 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE. MADE CONTACT W/ TENANT. TENANT ALLOWED ENTRY INTO TRAILER APPROX 8'X30' (TRAVEL TRAILER). MIN-HOUSING VIOLATION WERE FOUND AS WELL AS POSSIBLE WORK W/ OUT PERMITS. VIOLATIONS ARE AS FOLLOWS. WORK W/ OUT PERMITS: (1) NEW ROOF ASSEMBLY HAS BEEN ADDED ON TOP OF EXISTING ROOF. (2) ADDITION OF ELECTRICAL SPACE HEATER FOR LIVING ROOM, NO CENTRAL HEATING. LARGE TYPE SPACE HEATER DOES NOT WORK. ELECTRICAL: (1) LIFE LINE DOES NOT MATCH BREAKER, 50 AMP LIFE LINE & 30 AMP BREAKER. (2) SUB-PANEL HAS EXPOSED ELECTRICAL, CONDUCTOR NOT IN CONDUIT CHECK FOR PERMIT. (3) STRUCTURE APPEARS TO HAVE BEEN 2 WIRE SYSTEM, RECEPTACLES HAVE BEEN CHANGED OUT & 3 PRONG RECEPTACLES INSTALLED & LACKING MACHANICAL GROUNDS. (4) EXPOSED ELECTRICAL JUNCTION BOX IN CLOSET W/ EXPOSED ELECTRICAL CONDUCTOR. FIRE SAFETY- ACCESS CONTROL: (1) NO WORKING SMOKE DETECTOR (2) DETECTOR 1 - IS WITHIN 2 FEET OF STOVE. (2) HASP & PAD LOCK INSTALLED ON EASTSIDE DOOR WEATHER PROOFING: (1) SIDE ENTRY DOORS LACKING WEATHER STRIPPING, EVIDENCED BY LARGE AMOUNTS OF LIGHT SHINING THROUGH WHEN DOOR IS CLOSED. (2) SEVERAL WINDOWS THROUGHOUT STRUCTURE ARE BROKEN & MISSING SIDE ENTRY DOOR, WINDOW OPENING COVERED WITH PAPER ANOTHER WITH TAPE. FLOORING: (1) SEVERAL FLOOR TILES ARE BROKEN, CRACKED & PEELING UP. PLUMBING: (1) TENANT HAS NO HOT WATER, UNIT IS SUPPLIED WITH 5 GAL. HOT WATER HEATER UNDER SINK. TENANT STATED NO HOT WATER FOR 2 WEEKS, HAS TO USE NEIGHBORS SHOWER. ACCESSORY STRUCTURE: (1) STRUCTURE IS LACKING REQUIRED LANDING & STEPS. ELECTRICAL: (1) 4X4 WOODEN POST SUPPORTING TELEPHONE WIRING IS NOT ANCHORED PROPERLY, NOT AN APPROVED TERMITE APPLICATION (IMPROPER USE). PICTURES WERE TAKEN & N.O.V. WILL BE ISSUED. |
08/15/2005 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | VISITED SITE ON FOLLOW UP INSP. OWNER AND MAINTAINANCE SUPERVISOR WERE UNDER IMPRESSION DNR INSP. WOULD DO FINAL INSPECTION FOR INSTALLATION OF WALL FURNANCE. EXPLAINED TO OWNER AND SUPERVISOR, OWNER IS RESPONSIBLE FOR SCOURING PERMIT AND D.S.D TO DO FINAL INSPECTION. GAVE OWNER ADDRESS AND PHONE # OF D.S.D. OWNER STATED HE WILL SECURE PERMIT FOR INSTALLATION OF FURNACE AND CALL FOR FINAL INSPECTION THIS AFTERNOON. WILL CONTACT INSP. WHEN COMPLETED. INFORMED INSP 2 RICK SALDATE OF FINDING. INSP 2 ASKED IF INSP. lI HAD CONCERNS OF OWNER NOT FOLLOWING THROUGH. INSP I STATED NOW THAT OWNER HAS CORRECT INFORMATION INSP I FEELS OWNER WILL COMPLY. NOTE STRUCTURE HAS BEEN VACANT SINCE ISSUEING OF NOV. DO FW/UP (IN OFFICE) ON 8/30/2005 |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00911
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
11/30/2004 | CONTACTED BY PHONE |
04/12/2005 | CONTACTED BY MAILING |
12/22/2004 | NOTICE OF VIOLATION ISSUED |
11/30/2004 | COURT ORDERED ABATEMENT |