Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T04DV00834
Case Details
Entered Date:
10/13/2004
Applicant:
ROTHSCHILLER JANIS
Description:
COMPLAINT:MIN HOUSING - COOLER DUCTS ARE BLOWING RUST AND MINOR ROOF TAR. STOVE HAS BEEN RED TAGGED BY SWG (ELECT. WATER HEATER) NO HEATER INSTALLED.
Case Violations
Case Number: T04DV00834
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date | Code Statue |
---|---|
10/26/2006 | CONTACTED BY MAILING |
Outstanding Inspections
Case Number: T04DV00834
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
11/08/2004 | INSP - INITIAL CODE ENFORCMENT | JHURD | Correction Required | VISITED SITE, TOOK PICTURES, MET W/RESIDENT JAMES WHO ALLOWED ENTRY AND SHOWED ISSUES, FRONT DOOR GOES NOT SEAL PROPERLY CAN SEE LIGHT ON RIGHT SIDE, LIVINGROOM SHOWS 3 PRONG OUTLETS, (LOST MY TESTER). WEST WALL SHOWS WHERE GAS LINE COMING IN, NO CONNECTION, (HEAT) WEST WALL HAS EXPOSED ROMEX FROM CEILING TO OUTLET, OUTLET BOX OPEN ON TOP, ADDITION BUILT AND ATTACHED TO STRUCTURE, WEST SIDE, FRONT PART IN LIKE FAMILY ROOM, ROOM TO NORTH, BEDROOM SHOWS 3 PRONG OUTLETS. BEDROOM WINDOW TO SMALL FOR EGRESS, MOBILE HOME, TO EAST, ROOM MOBILE HOME BEDROOM NOT USED AS BEDROOM, LIGHT SWITCH ON WEST WALL LOOSE DOES NOT SEEM TO OPERATE ANYTHING, SHOWER AREA CAULKING SHOWS CRACKING AND SEPERATING BATH GFCI PROTECTED, KTICHEN, HOT WATER HEATER NEW (ELECT) EXPOSED ROMEX AT CONNECTION, WATER LINES ALTERED BY ADDING NEW FOR HOTWATER COOK STOVE DOES NOT OPERATE, USING 2 BURNER HOT PLATE, NO GAS ON TO UNIT COOK STOVE BURNER VALVES DO NOT OPERATE AS INTENDED. BOTH LEFT SIDE VALVES BROKEN, OUTLET EAST WALL BROKEN COVER PLATE, RESIDENT HAD TO BUY OWN FRIGERATOR, COOLER BLOWS OUT ALOT OF DIRT. DUST-TAR CHIPS, CARPORT AND SHED ATTACHED TO EAST SIDE OF STRUCTURE, 12 X 20, 2 X 4'S ATTACHED TO STRUCTURE ARE PUT UP IN PIECES, 2 X 4'S SPAN 12', 1 X 4 RAN NORTH TO SOUTH TO HOLD UP CORA GATE METAL ALL IN PIECES, INSIDE SHED, ELECTRICAL SERVICE, 2 SERVICE PANELS NORTH WALL, NOT ENERGIZED, 14 GAUGE WIRE GROUNDS, NEUTRALS TIED TOGETHER, WEST WALL NEW UPGRADE AND BOX, EXPOSED ROMEX 8 SEPERATE LINES. DWELLING LACKS HEAT NO SOURCE. FOUR GOING TO INTERIOR OF STRUCTURE AND GOING INTO STRUCTURE, OUTLETS, LIGHT FIXTURES, SWITCHES, OPENED ELECTRICAL BOX FOUND DOUBLING LUGGING ON 2 SEPERATE BREAKERS, NEUTRAL AND GROUNDS ON SAME LUG. NO SMOKE DETECTOR, ADDITION HAS BEEN ADDED TO WEST SIDE OF ORIGINAL MOBILE HOME, COMPLETE LENGTH. THIS HAS LIVINGROOM AND HOUSE'S BEDROOM, BEDROOM WINDOW TO SMALL FOR EGRESS, EXTERIOR SIDE WOODSIDING AT BOTTOM SHOWS DETERIORATION. HOLES AT BOTTOM, PRELIMINARY RESEARCH SHOWS NO PERMITS ON FILE FOR ADDITIONS, ELECTRICAL UPGRADE, NOTICE/VIOLATION TO FOLLOW. |
Completed Inspections
Case Status: COMPLIAN
Case Number: T04DV00834
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/03/2005 | EMERGENCY CALL OUT | JHURD | Approved | CALLED AND TALKED W/RICHARD (MANAGER) WHO WAS SURPRISED THAT CONTRACTOR HAS NOT FINALED PERMIT PER OUR LAST CONVERSATION. WHEN HE TALKED W/CONTRACTOR, CONTRACTOR STATED H |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00834
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
11/09/2004 | CONTACTED BY PHONE |
11/09/2004 | COURT ORDERED ABATEMENT |