Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T04DV00834

Parcel: 11803393B


Addresses:

2240 W 36TH ST


Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T04DV00834

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Correction Required

Date Description Inspector Results Comments
11/08/2004 INSP - INITIAL CODE ENFORCMENT Correction Required VISITED SITE, TOOK PICTURES, MET W/RESIDENT JAMES WHO ALLOWED ENTRY AND SHOWED ISSUES, FRONT DOOR GOES NOT SEAL PROPERLY CAN SEE LIGHT ON RIGHT SIDE, LIVINGROOM SHOWS 3 PRONG OUTLETS, (LOST MY TESTER). WEST WALL SHOWS WHERE GAS LINE COMING IN, NO CONNECTION, (HEAT) WEST WALL HAS EXPOSED ROMEX FROM CEILING TO OUTLET, OUTLET BOX OPEN ON TOP, ADDITION BUILT AND ATTACHED TO STRUCTURE, WEST SIDE, FRONT PART IN LIKE FAMILY ROOM, ROOM TO NORTH, BEDROOM SHOWS 3 PRONG OUTLETS. BEDROOM WINDOW TO SMALL FOR EGRESS, MOBILE HOME, TO EAST, ROOM MOBILE HOME BEDROOM NOT USED AS BEDROOM, LIGHT SWITCH ON WEST WALL LOOSE DOES NOT SEEM TO OPERATE ANYTHING, SHOWER AREA CAULKING SHOWS CRACKING AND SEPERATING BATH GFCI PROTECTED, KTICHEN, HOT WATER HEATER NEW (ELECT) EXPOSED ROMEX AT CONNECTION, WATER LINES ALTERED BY ADDING NEW FOR HOTWATER COOK STOVE DOES NOT OPERATE, USING 2 BURNER HOT PLATE, NO GAS ON TO UNIT COOK STOVE BURNER VALVES DO NOT OPERATE AS INTENDED. BOTH LEFT SIDE VALVES BROKEN, OUTLET EAST WALL BROKEN COVER PLATE, RESIDENT HAD TO BUY OWN FRIGERATOR, COOLER BLOWS OUT ALOT OF DIRT. DUST-TAR CHIPS, CARPORT AND SHED ATTACHED TO EAST SIDE OF STRUCTURE, 12 X 20, 2 X 4'S ATTACHED TO STRUCTURE ARE PUT UP IN PIECES, 2 X 4'S SPAN 12', 1 X 4 RAN NORTH TO SOUTH TO HOLD UP CORA GATE METAL ALL IN PIECES, INSIDE SHED, ELECTRICAL SERVICE, 2 SERVICE PANELS NORTH WALL, NOT ENERGIZED, 14 GAUGE WIRE GROUNDS, NEUTRALS TIED TOGETHER, WEST WALL NEW UPGRADE AND BOX, EXPOSED ROMEX 8 SEPERATE LINES. DWELLING LACKS HEAT NO SOURCE. FOUR GOING TO INTERIOR OF STRUCTURE AND GOING INTO STRUCTURE, OUTLETS, LIGHT FIXTURES, SWITCHES, OPENED ELECTRICAL BOX FOUND DOUBLING LUGGING ON 2 SEPERATE BREAKERS, NEUTRAL AND GROUNDS ON SAME LUG. NO SMOKE DETECTOR, ADDITION HAS BEEN ADDED TO WEST SIDE OF ORIGINAL MOBILE HOME, COMPLETE LENGTH. THIS HAS LIVINGROOM AND HOUSE'S BEDROOM, BEDROOM WINDOW TO SMALL FOR EGRESS, EXTERIOR SIDE WOODSIDING AT BOTTOM SHOWS DETERIORATION. HOLES AT BOTTOM, PRELIMINARY RESEARCH SHOWS NO PERMITS ON FILE FOR ADDITIONS, ELECTRICAL UPGRADE, NOTICE/VIOLATION TO FOLLOW.