Case: T04DV00194
Case Details
Entered Date:
03/08/2004
Applicant:
ELDRIDGE JONAS D & SARAH D JT/RS
Description:
COMPLAINT:MIN HOUSING-SUBSTANDARD LIVING CONDITIONS-
Case Violations
Case Number: T04DV00194
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 04/27/2004 | NOTICE OF VIOLATION ISSUED |
| 04/27/2004 | COURT ORDERED ABATEMENT |
Outstanding Inspections
Case Number: T04DV00194
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/09/2004 | INSP - INITIAL CODE ENFORCMENT | RCAMACHO | Correction Required | MET ON SITE WITH TFD INSPECTOR STEVE RUETZ, PASTOR RANDY LYONS, MANAGER OF PROPERTY, JAMES HURD FOR SCHEDULED INSPECTION. EXTERIOR FOUND: JUNKED MOTOR VEHICLES TO INCLUDE 1) WHITE CHEVY VAN NO TAGS 2) WHITE MAZDA STATION WAGON 3) BLACK PONTIAC FIERRO 4) SILVER DODGE MINI VAN 5) BLUE LINCOLN CONTINENTAL TRAVEL TRAILER USED FOR STORAGE TEMPORARY SHOWER AREA WITH PLUMBING TEMPORARY CANOPY APPROX MEASUREMENTS 16' X 40'. WEEDS, OVERGROWN VEGETATION AND DEBRIS AT ALL YARD AREAS CHAIN LINK FENCING AT FRONT WEST LOT LINE HAS NOT BEEN MAINTAINED BROKEN WINDOW GLASS SOME UNITS SCUFFEL DRAIN SPOUTS NOT PROPERLY SECURED TO EXTERIOR WALLS ALL UNITS. UNIT # 724 FOUND: UNIT HAS BEEN MODIFIED AND CONVERTED INTO ONE LARGE UNIT. SQUARE FOOTAGE HAS BEEN ADDED TO EAST END OF UNIT. BROKEN WINDOW GLASS FRONT PORCH AREA REBAR STICKING OUT OF SLAB FRONT DOOR TRIM AND JAMB IN NEED OF REPAIR FRONT DOOR LACKS WEATHER STRIP AND SWEEP LIVING ROOM CONVENIENCE OUTLETS TEST OPEN GROUND CEILING IN HALLWAY IN NEED OF REPAIR BATHROOM EXHAUST FAN IS MISSING COVER GFCI OUTLET IN BATHROOM DOES NOT TEST COMMODE TANK MISSING COVER SOUTH BEDROOM DOOR OFF HINGES HOLES IN SHEETROCK AND CLOSET DOORS FOUND SPACE HEATER IN BEDROOM EXPOSED WIRING IN MECHANICAL ROOM NEW WATER HEATER INSTALLED IN MECHANICAL ROOM INTAKE REGISTER NOT SECURED TO WALL KITCHEN DOOR IN NEED OF REPLACEMENT 2" CONDUIT NOT SECURED TO WALL KITCHEN SINK CABINET BASE DETERIORATED KITCHEN COUNTER TOP NOT SECURED TO CABINETS PANTRY IN NEED OF REPAIR. ADDED AREA FOUND: 7 BEDROOMS WILL BE MARKED WITH NUMBERS ACCORDING TO RANDY LYONS. OLD LIVING ROOM AREA CONVERTED INTO BEDROOM. EXTERIOR DOOR HAS BEEN SCREWED SHUT. EGRESS BLOCKED FROM INTERIOR WITH FURNITURE. CLOSET AREA WALL NOT SEALED TO THE EXTERIOR WHERE WALL MEETS CLOSET. EXPOSED WIRING AT HALLWAY FIXTURE. COMMODE TANK MISSING. NEW WATER HEATER INSTALLED IN MECHANICAL ROOM. POSSIBLE W/O PERMITS. EXPOSED WIRING IN MECHANICAL ROOM. BATH VANITY DOORS MISSING. FLOORING COMING UP IN BATHROOM. OLD KITCHEN CONVERTED TO BEDROOM. EXTERIOR DOOR SCREWED SHUT. HALLWAY CEILING IN NEED OF REPAIR. OVERLOADING OF CONVENIENCE OUTLET. NUMEROUS EXTENSION CORDS TO ONE OUTLET. DUE TO CONVERSION OF DWELLING ONLY ONE OUTLET IN BEDROOM. FURNACE HAS EXPOSED WIRING. LEAK AT BEDROOM CEILING. CLOSET DOOR AND JAMB LOOSE IN BEDROOM. UNIT # 726 FOUND: FRONT DOOR LACKS REQUIRED THRESHOLD AND SWEEP. DOOR JAMB IN NEED OF REPAIR. EXTERIOR DOORS TO EAST AND WEST IN HALLWAY. 220 OUTLET IN BEDROOM. BATHROOM OUTLET OVER BATH VANITY LOOSE. EXPOSING WIRES. NEW ELECTRIC WATER HEATER WITH EXPOSED WIRING. SUBPANEL IN BATHROOM MISSING BLANKS. CONVENIENCE OUITLET IN HALLWAY LOOSE. BRICK AT NORTHWALL IS DIFFERENT TYPE AS EAST AND WEST WALLS. OBVIOUS SIGNS OF CONVERSION THROUGHOUT UNIT. BEDROOM OUTLETS TEST OPEN GROUND. NEW SIDING AT EXTERIOR SOUTH WALL. BROKEN WINDOW GLASS. FRONT DOOR COMING OFF HINGES. DOOR LACKS REQUIRED WEATHER STRIP. NEW DOOR INSTALLED AT EAST WALL. KITCHEN CABINETS MISSING DOORS AND DRAWERS. REAR KITCHEN DOOR IN NEED OF REPLACEMENT. DOOR TRIM MISSING. DOOR LACKS REQUIRED WEATHER STRIP AND SWEEP. APPLIANCE CORD TO LIGHT FIXTURE OVER KITCHEN SINK. NEW WATER HEATER (ELECTRIC) WITH EXPOSED WIRING. BEDROOM WINDOW BLOCKING EGRESS WITH FURNITURE ON INTERIOR. COOLER REGISTER MISSING. SUBPANEL MISSING BLANK COVERS. UNIT # 728 FOUND: FRONT EXTERIOR DOOR LACKS REQUIRED WEATHER STRIP, SWEEP AND THRESHOLD. HINGE SIDE DOORJAMB LOOSE FROM WALL. EXHAUST FAN IN BATHROOM DOES NOT OPERATE. BEDROOM WINDOW EGRESS BLOCKED WITH FURNITURE AT INTERIOR. SPACE HEATERS FOUND. RANDY LYONS STATES HE USES SPACE HEATERS FOR ECONOMIC REASONS. INSPECTOR INFORMS HIM SPACE HEATERS MAY NOT BE USED IN THE FUTURE. ALL FURNACES MUST BE SERVICED TO OPERATE PROPERLY FOR NEXT WINTER SEASON. NEW HEAT PUMP INSTALLED ON ROOF. POSSIBLE WORK WITHOUT PERMITS. NEW WATER HEATER INSTALLED (ELECTRIC). KITCHEN SINK FIXTURE LOOSE AND LEAKS. REAR KITCHEN DOORJAMB BUSTED AT KNOB SIDE. KITCHEN FLOORING COMING UP. UNIT # 730 OFFICE FOUND: KITCHEN EXTERIOR DOOR LACKS REQUIRED WEATHER STRIP AND SWEEP. KITCHEN CABINETS MISSING DRAWERS. NEW HEAT PUMP INSTALLED ON ROOF. POSSIBLE W/O PERMITS. BEDROOM WINDOWS BOARDED FROM INTERIOR. NOT ALLOWING SAFE AND RAPID EGRESS IN EMERGENCY SITUATIONS. EXHAUST FAN IN BATHROOM DOES NOT OPERATE. COMMODE NOT SECURED TO WALL. TENANT (RANDY LYONS) MAY CHOOSE TO SWITCH BEDROOMS INSTEAD OF REMOVING BOARDS FROM INTERIOR OF REAR BEDROOM. WHICH MAY THEN BE USED AS STORAGE. BEDROOM OUTLET OVERLOADED WITH NUMEROUS EXTENSION CORDS. GFCI OUTLET IN BATHROOM DOES NOT TEST. UNIT # 732 FRONT DOOR JAMB IN NEED OF REPAIR. DEAD BOLT DOES NOT ALIGN WITH STRIKE PLATE. SOUTH CLOSET DOORS OFF HINGES. SHEETROCK BOWED AND SAGGING AT CEILING. BATH EXHAUST FAN DOES NOT OPERATE. NEW WATER HEATER IN BATHROOM (ELECTRIC). MECHANICAL ROOM DOOR OFF HINGES. NORTH BEDROOM EGRESS BLOCKED WITH FURNITURE. NORTH BATHROOM EXHAUST FAN DOES NOT OPERATE. REAR DOORJAMB BUSTED IN NEED OF REPLACEMENT. CHAIN LINK FENCINGAGAINST METER. HAZARDOUS CONDITION. WOOD FENCING DILAPIDATED IN NEED OF REPAIR. CHAIN LINK GATE DOES NOT OOPERATE FOR EMERGENCY ESCAPE. DRAINS FROM SCUFFEL NOT SECURED TO WALL. UNIT # 734 FOUND: SOUTH BEDROOM WINDOW EGRESS BLOCKED WITH FURNITURE COMMODE NOT SECURED TO WALL. BATHROOM EXHAUST FAN DOES NOT OPERATE. SPACE HEATER IN BEDROOM. INSPECTOR INFORMED RANDY LYONS SPACE HEATERS COULD NO LONGER BE USED IN THE FUTURE. ALL FORCED AIR FURNACES MUST BE SERVICED TO A SAFE WORKING CONDITION BEFORE NEXT WINTER SEASON. LIVING ROOM CIRCUITS TEST OPEN GROUND. SOME CONVENIENCE OUTLETS DO NOT OPERATE. REAR DOOR COMING OFF HINGES. REAR WOODEN FENCE DILAPIDATED AND IN NEED OF REPAIR. LIKELY TO FAIL OR COLLAPSE. NEW PLUMBING LINES FROM HOSE BIB TO TEMPORARY SHOWER AREA. NORTH BEDROOM FOUND SPACE HEATER ON. BEDROOM WINDOW BLOCKED EGRESS WITH FURNITURE. TILE AT BATHROOM ENTRY TRIP HAZARD. UNIT # 736 FOUND: SOUTH BEDROOM CEILING BOWING. IN NEED OF REPAIR. BROKEN WINDOW GLASS. FRONT DOOR FALLING OFF HINGES. HOLES IN SHEETROCK THROUGHOUT UNIT. MISSING CONVENIENCE OUTLET AND SWITCH COVER PLATES MISSING THROUGHOUT UNIT. LIVING ROOM CIRCUIT TESTS REVERSE POLARITY. THERMOSTAT DAMAGED. FURNACE IN NEED OF SERVICE. CEILING IN MECHANICAL FALLING. BROKEN WINDOW GLASS NORTH BEDROOM WINDOW. NORTH BATHROOM POCKET DOOR DOES NOT OPERATE. BEDROOM DOORS HAVE HOLES AND ARE OFF HINGES. JUNK AND DEBRIS REAR YARD AREA. REAR DOOR COMING OFF TOP HINGE. KITCHEN COUNTER TOP LOOSE FROM CABINETS. UNIT # 738 FOUND: FRONT EXTERIOR DOORJAMB BACKSET NEEDS ADJUSTMENT. JAMB MISSING STRIKE PLATE AT DEAD BOLT AT JAMB. THERMOSTAT MISSING AT LIVING ROOM WALL. LIVING ROOM WINDOW DOES NOT LOCK. MECHANICAL ROOM DOOR REMOVED. REAR DOOR WEATHER STRIP NEEDS ADJUSTMENT. KITCHEN CABINETS IN NEED OF REPAIR. MISSING DRAWERS AND DOORS. EXTENSION CORD FROM KITCHEN TO BEDROOM CONNECTED TO SPACE HEATER. REAR YARD JUNK AND DEBRIS. HOLES IN SHEETROCK AND INTERIOR DOORS THROUGHOUT UNIT. BATHROOM CEILING NOT MAINTAINED FREE FROM MILDEW. COMMODE NOT SECURED TO FLOOR. HOLES IN SHEETROCK BELOW BATH VANITY. BATH WALLS NOT FINISHED. GFCI OUTLET ABOVE BATH VANITY FAULTY. COOLER REGISTER IN BATHROOM NOT SECURED TO WALL. SOUTH BEDROOM EXPOSED WIRING IN CLOSET CEILING. MISSING SHEETROCK AT POCKET DOOR. HOLES IN BATHROOM WALLS AND BEHIND COMMODE. COOMODE NOT SECURED TO FLOOR. BATH VANITY BASE DETERIORATED. EXHAUST FAN DOES NOT OPERTAE. |
| 06/02/2004 | INSP - FOLLOW UP CODE ENFORCE | RCAMACHO | Correction Required | SCHEDULED FOLLOW UP INSPECTION MET ON SITE WITH MARTIN ROMERO, STEVE RUETZ (TFD) AND RANDY LYONS. ALSO ON SITE CONTRACTOR FOR THE OWNER DOUG KASIAN AND ASSISTANT PASTOR TIM SEIDEL. WALKED INTERIOR AND EXTERIOR OF ALL UNITS. FOLLOW UP INSPECTION FOR ALL MINIMUM HOUSING VIOLATIONS ON NOTICE DATED 5/13/04. WORK WITHOUT PERMITS ISSUES ARE BEING HANDLED BY AN ARCHITECT ( JEFF LATHAM) RETAINED BY CONTRACTOR DOUG KASIAN. MARTIN ROMERO ASSISTED INSPECTOR CAMACHO WITH PICTURES. FOLLOW UP INSPECTION FOUND: UNIT 724: SMOKE DETECTORS INSTALLED IN ALL SLEEPING AREAS. ACCEPTED BY STEVE RUETZ. ALL FURNITURE BLOCKING EGRESS AT BEDROOM WINDOWS HAS BEEN PROPERLY RELOCATED AND BEDROOM DOOR HAS BEEN REPAIRED TO OPERATE PROPERLY. COMPLIANCE. FORCED AIR FURNACE HAS BEEN PROPERLY SERVICED TO A SAFE WORKING CONDITION. RANDY LYONS STATES ALL FURNACES HAVE BEEN SERVICED. HE WILL SUPPLY INSPECTOR CAMACHO A COPY OF THE INVOICE. COMPLIANCE. PERMIT # T04EL00963 APPLIED 5/10/04 FOR ELECTRICAL GENERAL REPAIR. AS ORDERED ON NOTICE.FURNACE INTAKE REGISTER HAS BEEN PROPERLY SECURED TO WALL. BATHROOM EXHAUST FAN COVER INSTALLED. COMPLIANCE. COMMODE TANK COVER INSTALLED. COMPLIANCE. CEILING IN HALLWAY HAS BEEN REPAIRED. LACKS PAINT. SOUTH BEDROOM DOOR HAS BEEN REHUNG PROPERLY AT HINGES.HOLES STILL REMAIN IN SHEETROCK WALLS AND CLOSET DOORS. CLOSET DOORS WILL BE REMOVED AND SHEETROCK REPAIRS WIL BE COMPLETED AT NEXT INSPECTION. KITCHEN SINK BASE CABINET REPAIRED. KITCHEN COUNTER TOPS HAVE BEEN SECURED TO BASE CABINETS. PANTRY HAS BEEN REPAIRED TO A STRUCTUALLY SOUND CONDITION.BATHROOM VANITY DOORS HAVE BEEN REPLACED. NEW FLOORING INSTALLED AT BATHROOM FLOOR.CLOSET DOOR AND JAMB IN BEDROOM REPAIRED. FRONT EXTERIOR AND REAR KITCHEN DOORS HAVE BEEN REPAIRED TO FUNCTION PROPERLY IN EMERGENCY SITUATIONS. ALL BROKEN WINDOW GLASS HAS BEEN REPLACED WITH NEW. ALL REQUIRED WEATHER STRIP INSTALLED TO ALL EXTERIOR DOORS. ROOF LEAK AT CEILING REPAIRED. BEDROOM CLOSET WALLS REMAIN UN SEALED. MAINT. PERSON CAULKED CRACKS WHILE ON SITE. COMPLIANCE. REBAR AT FRONT PORCH AREA REMAINS IN PLACE. MAINT. PERSON WILL SCHEDULE REMOVAL. UNIT #726 ALL FURNITURE BLOCKING EGRESS HAS IN BEDROOM BEEN PROPERLY RELOCATED.FORCED AIR FURNACE HAS BEEN SERVICED TO A SAFE WORKING CONDITION. ALL SPACE HEATERS REMOVED. PERMIT# T04EL00962 APPLIED 5/10/04 ELECTRICAL GENERAL REPAIR FOR ALL ELECTRICAL REPAIRS ON NOTICE. ALL MISSING COOLER REGISTERS HAVE BEEN REPLACED WITH NEW. KITCHEN CABINETS HAVE BEEN REPAIRED TO A STRUCTUALY SOUND CONDITION. COMPLIANCE. UNIT #728 ALL BEDROOM FURNITURE HAS BEEN PROPERLY RELOCATED FOR EMERGENCY EGRESS.FORCED AIR FURNACE HAS BEEN SERVICED TO A SAFE WORKING CONDITION. EXHAUST FAN IN BATHROOM STILL DOES NOT OPERATE. KITCHEN SINK FIXTUREHAS NOT BEEN REPAIRED. STILL LEAKS. KITCHEN FLOORING HAS BEEN REPLACED WITH NEW.REAR EXTERIOR KITCHEN DOOR HAS BEEN REPAIRED TO FUNCTION PROPERLY IN EMERGENCY SITUATIONS. FRONT EXTERIOR DOOR LACKS THRESHOLD AND SWEEP. UNIT # 730 BOARDS HAVE BEEN REMOVED FROM WINDOWS THAT WERE BLOCKING EGRESS. FORCED AIR FURNACE HAS BEEN SERVICED TO OPERATE IN A SAFE CONDITION. EXHAUST FAN IN BATHROOM REAPIRED TO OPERATE CORRECTLY. COMMODE HAS BEEN PROPERLY SECURED TO FLOOR. KITCHEN CABINETS HAVE BEEN REPAIRED TO A STRUTUALLY SOUND CONDITION. KITCHEN EXTERIOR DOOR HAS BEEN WEATHERED. COMPLIANCE. UNIT #732 NORTH BEDROOM FURNITURE HAS BEEN RELOCATED FROM BLOCKING EGRESS.CHAIN LINK FENCING HAS BEEN REMOVED FROM BACK YARD AREA ALLOWING SAFE EGRESS IN EMERGENCY SITUATIONS. FORCED AIR FURNACE HAS BEEN SERVICED TO A SAFE OPERATING CONDITION. EXHAUST FAN IN BATHROOM HAS BEEN REPAIRED.CHAIN LINK DENCING HAS BEEN REMOVED FROM MAIN SERVICE PANEL. SHEETROCK AT CEILING HAS BEEN REPAIRED. SOUTH CLOSET DOOR REPAIRED OFF HINGES.FRONT EXTERIOR DOOR JAMB NOT REPAIRED. DEADBOLT STILL DOES NOT ALIGN WITH STRIKE PLATE. WOOD FENCING AT NORTH LOT LINE HAS NOT BEEN REPAIRED. ALL ROOF DRAIN DOWN SPOUTS HAVE BEEN PROPERLY SECURED TO WALLS. NEW PLUMBING LINES TO OUTDOOR SHOWER HAVE BEEN DELETED. A PERMIT IS NO LONGER NECESSARY. UNIT # 734 ALL FURNITURE BLOCKING EGRESS IN BEDROOMS HAS BEEN PROPERLY RELOCATED. FORCED AIR FURNACE HAS BEEN SERVICED TO A SAFE WORKING CONDITION. EXHAUST FAN IN BATHROOM OPERATES PROPERLY. PERMIT# T04EL00960 APPLIED 5/10/04 FOR ELECTRICAL GENERAL REPAIR AS ORDERED ON NOTICE. BATHROOM COMMODE SECURED TO FLOOR. DAMAGED BATHROOM FLOORING REPLACED WITH NEW. EXTERIOR DOOR REPAIRED TO FUNCTION PROPERLY IN EMERGENCY SITUATIONS. WOOD FENCING AT NORTH LOT LINE REMAINS IN NEED OF REPAIR. UNIT # 736 FORCED AIR FURNACE HAS BEEN SERVICED IN A SAFE WORKING CONDITION. PERMIT # T04EL00958 APPLIED 5/10/04 FOR ELECTRICAL GENERAL REPAIR AS ORDERED ON NOTICE. THERMOSTAT REPLACED WITH NEW. CEILING IN SOUTH BEDROOM REPAIRED HAS BEEN REPAIRED. LACKS PAINT. BEDROOM DOORS REPAIRED. HOLES IN SHEETROCK THROUGHOUT DWELLING HAVE BEEN PATCHED. KITCHEN COUNTER TOPS HAVE BEEN PROPERLY SECURED TO BASE CABINETS. NORTH BATHROOM POCKET DOOR REMAINS INOPERABLE. REAR EXTERIOR DOOR PROPERLY REPAIRED. FRONT EXTERIOR DOOR NEEDS MORE ATTENTION. HINGES REMAIN LOOSE DOOR DOES NOT FUNCTION PROPERLY. ALL BROKEN WINDOW GLASS REPLACED WITH NEW. UNIT #738: FORCED AIR FURNACE HAS BEEN SERVICED TO A SAFE WORKING CONDITION. EXHAUST FAN IN BATHROOM REPAIRED TO OPERATE. PERMIT # T04EL00959 APPLIED 5/10/04 ELECTRICAL GENERAL REPAIR. THERMOSTAT REPALCED WITH NEW.MECHANICAL ROOM DOOR COMBUSTION VENT ADDED TO BOTTOM. COOLER REGISTER IN BATHROOM SECURED TO WALL. BATHROOM COMMODE SECURED TO FLOOR. BATHROOM CEILING HAS NOT BEEN MAINTAINED FREE FROM MILDEW. HOLES IN SHEETROCK PATCHED THROUGH OUT DWELLING. MISSING SHEETROCK REPLACED WITH NEW. KITCHEN CABINETS REPAIRED TO A STRUCTUALLY SOUND CONDITION. FRONT EXTERIOR HAS NOT BEEN REPAIRED TO ALLOW SAFE AND RAPID EGRESS. REAR EXTERIOR DOOR HAS BEEN PROPERLY WEATHERED. EXTERIOR: PLUMBING LINES TO TEMPORARY EXTERIOR SHOWER HAVE BEEN DELETED. (NO PERMIT NEEDED). ALL BROKEN WINDOW GLASS HAS BEEN REPLACED WITH NEW. EXTERIOR WOOD OVERHANGS REMAIN UNPROTECTED. LACK PAINT. ENTIRE YARD AREAS HAVE BEEN MAINTAINED FREE FROM ACCUMULATION OF VEGETATION. CHAIN LINK FENCING REMAINS IN DANGER OF FAILURE OR COLLAPSE. ALL JUNKED MOTOR VEHICLES HAVE BEEN REMOVED FROM SITE. RANDY LYONS WILL FAX AN INVOICE TO INSPECTOR CAMACHO ON ALL SERVICES COMPLETED TO FORCED AIR FURNACES ON SITE. AN ARCHITECT IS WORKING ON DRAWINGS FOR ALL NECESSARY PERMIT ISSUES. INSPECTOR CAMACHO WILL FAX RANDY LYONS REMAINING UNABATED VIOLATIONS ON PROPERTY. (SEE PICTURES). INSPECTOR ROMERO ON SITE TO ASSIST WITH INSPECTION NOTIFIED RANDY LYONS DUMPSTER IS LOCATED TO CLOSE TO THE STREET. INFORMED RANDY DUMPSTER MUST BE LOCATED NO LESS THAN 6 FEET FROM STREET. INSPECTOR CAMACHO RECOMMENDS NEW DUMPSTER OR ENCLOSURE BE PUT ON SITE PLAN SUBMITTED TO DSD. OWNER AND RANDY LYONS HAVE MADE SIGNIFICANT PROGRESS ON MINIMUM HOUSING ISSUES. A 30-DAY FOLLOW UP WILL BE SCHEDULED FOR REMAINING VIOLATIONS. INSPECTOR CAMACHO WILL FAX REMAING VIOLATIONS TO RANDY LYONS. F/U 7/6/04. |