Case: T04DV00194

Parcel: 117032290


Addresses:

732 N 10TH AV


Inspection Status: Correction Required

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T04DV00194

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/09/2004 INSP - INITIAL CODE ENFORCMENT Correction Required MET ON SITE WITH TFD INSPECTOR STEVE RUETZ, PASTOR RANDY LYONS, MANAGER OF PROPERTY, JAMES HURD FOR SCHEDULED INSPECTION.
EXTERIOR FOUND:
JUNKED MOTOR VEHICLES TO INCLUDE
1) WHITE CHEVY VAN NO TAGS
2) WHITE MAZDA STATION WAGON
3) BLACK PONTIAC FIERRO
4) SILVER DODGE MINI VAN
5) BLUE LINCOLN CONTINENTAL
TRAVEL TRAILER USED FOR STORAGE
TEMPORARY SHOWER AREA WITH PLUMBING
TEMPORARY CANOPY APPROX MEASUREMENTS 16' X 40'.
WEEDS, OVERGROWN VEGETATION AND DEBRIS AT ALL YARD AREAS
CHAIN LINK FENCING AT FRONT WEST LOT LINE HAS NOT BEEN MAINTAINED
BROKEN WINDOW GLASS SOME UNITS
SCUFFEL DRAIN SPOUTS NOT PROPERLY SECURED TO EXTERIOR WALLS ALL UNITS.


UNIT # 724 FOUND:
UNIT HAS BEEN MODIFIED AND CONVERTED INTO ONE LARGE UNIT. SQUARE FOOTAGE HAS BEEN ADDED TO EAST END OF UNIT.
BROKEN WINDOW GLASS
FRONT PORCH AREA REBAR STICKING OUT OF SLAB
FRONT DOOR TRIM AND JAMB IN NEED OF REPAIR
FRONT DOOR LACKS WEATHER STRIP AND SWEEP
LIVING ROOM CONVENIENCE OUTLETS TEST OPEN GROUND
CEILING IN HALLWAY IN NEED OF REPAIR
BATHROOM EXHAUST FAN IS MISSING COVER
GFCI OUTLET IN BATHROOM DOES NOT TEST
COMMODE TANK MISSING COVER
SOUTH BEDROOM DOOR OFF HINGES
HOLES IN SHEETROCK AND CLOSET DOORS
FOUND SPACE HEATER IN BEDROOM
EXPOSED WIRING IN MECHANICAL ROOM
NEW WATER HEATER INSTALLED IN MECHANICAL ROOM
INTAKE REGISTER NOT SECURED TO WALL
KITCHEN DOOR IN NEED OF REPLACEMENT
2" CONDUIT NOT SECURED TO WALL
KITCHEN SINK CABINET BASE DETERIORATED
KITCHEN COUNTER TOP NOT SECURED TO CABINETS
PANTRY IN NEED OF REPAIR.
ADDED AREA FOUND:
7 BEDROOMS WILL BE MARKED WITH NUMBERS ACCORDING TO RANDY LYONS.
OLD LIVING ROOM AREA CONVERTED INTO BEDROOM. EXTERIOR DOOR HAS BEEN SCREWED SHUT.
EGRESS BLOCKED FROM INTERIOR WITH FURNITURE.
CLOSET AREA WALL NOT SEALED TO THE EXTERIOR WHERE WALL MEETS CLOSET.
EXPOSED WIRING AT HALLWAY FIXTURE.
COMMODE TANK MISSING.
NEW WATER HEATER INSTALLED IN MECHANICAL ROOM. POSSIBLE W/O PERMITS.
EXPOSED WIRING IN MECHANICAL ROOM.
BATH VANITY DOORS MISSING.
FLOORING COMING UP IN BATHROOM.
OLD KITCHEN CONVERTED TO BEDROOM.
EXTERIOR DOOR SCREWED SHUT.
HALLWAY CEILING IN NEED OF REPAIR.
OVERLOADING OF CONVENIENCE OUTLET. NUMEROUS EXTENSION CORDS TO ONE OUTLET. DUE TO CONVERSION OF DWELLING ONLY ONE OUTLET IN BEDROOM.
FURNACE HAS EXPOSED WIRING.
LEAK AT BEDROOM CEILING.
CLOSET DOOR AND JAMB LOOSE IN BEDROOM.

UNIT # 726 FOUND:

FRONT DOOR LACKS REQUIRED THRESHOLD AND SWEEP. DOOR JAMB IN NEED OF REPAIR.
EXTERIOR DOORS TO EAST AND WEST IN HALLWAY.
220 OUTLET IN BEDROOM.
BATHROOM OUTLET OVER BATH VANITY LOOSE. EXPOSING WIRES.
NEW ELECTRIC WATER HEATER WITH EXPOSED WIRING.
SUBPANEL IN BATHROOM MISSING BLANKS.
CONVENIENCE OUITLET IN HALLWAY LOOSE.
BRICK AT NORTHWALL IS DIFFERENT TYPE AS EAST AND WEST WALLS. OBVIOUS SIGNS OF CONVERSION THROUGHOUT UNIT.
BEDROOM OUTLETS TEST OPEN GROUND.
NEW SIDING AT EXTERIOR SOUTH WALL.
BROKEN WINDOW GLASS.
FRONT DOOR COMING OFF HINGES. DOOR LACKS REQUIRED WEATHER STRIP.
NEW DOOR INSTALLED AT EAST WALL.
KITCHEN CABINETS MISSING DOORS AND DRAWERS.
REAR KITCHEN DOOR IN NEED OF REPLACEMENT. DOOR TRIM MISSING. DOOR LACKS REQUIRED WEATHER STRIP AND SWEEP.
APPLIANCE CORD TO LIGHT FIXTURE OVER KITCHEN SINK.
NEW WATER HEATER (ELECTRIC) WITH EXPOSED WIRING.
BEDROOM WINDOW BLOCKING EGRESS WITH FURNITURE ON INTERIOR.
COOLER REGISTER MISSING.
SUBPANEL MISSING BLANK COVERS.

UNIT # 728 FOUND:
FRONT EXTERIOR DOOR LACKS REQUIRED WEATHER STRIP, SWEEP AND THRESHOLD. HINGE SIDE DOORJAMB LOOSE FROM WALL.
EXHAUST FAN IN BATHROOM DOES NOT OPERATE.
BEDROOM WINDOW EGRESS BLOCKED WITH FURNITURE AT INTERIOR.
SPACE HEATERS FOUND. RANDY LYONS STATES HE USES SPACE HEATERS FOR ECONOMIC REASONS. INSPECTOR INFORMS HIM SPACE HEATERS MAY NOT BE USED IN THE FUTURE. ALL FURNACES MUST BE SERVICED TO OPERATE PROPERLY FOR NEXT WINTER SEASON.
NEW HEAT PUMP INSTALLED ON ROOF. POSSIBLE WORK WITHOUT PERMITS.
NEW WATER HEATER INSTALLED (ELECTRIC).
KITCHEN SINK FIXTURE LOOSE AND LEAKS.
REAR KITCHEN DOORJAMB BUSTED AT KNOB SIDE.
KITCHEN FLOORING COMING UP.

UNIT # 730 OFFICE FOUND:
KITCHEN EXTERIOR DOOR LACKS REQUIRED WEATHER STRIP AND SWEEP.
KITCHEN CABINETS MISSING DRAWERS.
NEW HEAT PUMP INSTALLED ON ROOF. POSSIBLE W/O PERMITS.
BEDROOM WINDOWS BOARDED FROM INTERIOR. NOT ALLOWING SAFE AND RAPID EGRESS IN EMERGENCY SITUATIONS.
EXHAUST FAN IN BATHROOM DOES NOT OPERATE.
COMMODE NOT SECURED TO WALL.
TENANT (RANDY LYONS) MAY CHOOSE TO SWITCH BEDROOMS INSTEAD OF REMOVING BOARDS FROM INTERIOR OF REAR BEDROOM. WHICH MAY THEN BE USED AS STORAGE.
BEDROOM OUTLET OVERLOADED WITH NUMEROUS EXTENSION CORDS.
GFCI OUTLET IN BATHROOM DOES NOT TEST.

UNIT # 732
FRONT DOOR JAMB IN NEED OF REPAIR. DEAD BOLT DOES NOT ALIGN WITH STRIKE PLATE.
SOUTH CLOSET DOORS OFF HINGES.
SHEETROCK BOWED AND SAGGING AT CEILING.
BATH EXHAUST FAN DOES NOT OPERATE.
NEW WATER HEATER IN BATHROOM (ELECTRIC). MECHANICAL ROOM DOOR OFF HINGES.
NORTH BEDROOM EGRESS BLOCKED WITH FURNITURE.
NORTH BATHROOM EXHAUST FAN DOES NOT OPERATE.
REAR DOORJAMB BUSTED IN NEED OF REPLACEMENT.
CHAIN LINK FENCINGAGAINST METER. HAZARDOUS CONDITION.
WOOD FENCING DILAPIDATED IN NEED OF REPAIR.
CHAIN LINK GATE DOES NOT OOPERATE FOR EMERGENCY ESCAPE.
DRAINS FROM SCUFFEL NOT SECURED TO WALL.

UNIT # 734 FOUND:
SOUTH BEDROOM WINDOW EGRESS BLOCKED WITH FURNITURE
COMMODE NOT SECURED TO WALL.
BATHROOM EXHAUST FAN DOES NOT OPERATE.
SPACE HEATER IN BEDROOM. INSPECTOR INFORMED RANDY LYONS SPACE HEATERS COULD NO LONGER BE USED IN THE FUTURE. ALL FORCED AIR FURNACES MUST BE SERVICED TO A SAFE WORKING CONDITION BEFORE NEXT WINTER SEASON.
LIVING ROOM CIRCUITS TEST OPEN GROUND. SOME CONVENIENCE OUTLETS DO NOT OPERATE.
REAR DOOR COMING OFF HINGES.
REAR WOODEN FENCE DILAPIDATED AND IN NEED OF REPAIR. LIKELY TO FAIL OR COLLAPSE.
NEW PLUMBING LINES FROM HOSE BIB TO TEMPORARY SHOWER AREA.
NORTH BEDROOM FOUND SPACE HEATER ON.
BEDROOM WINDOW BLOCKED EGRESS WITH FURNITURE.
TILE AT BATHROOM ENTRY TRIP HAZARD.

UNIT # 736 FOUND:
SOUTH BEDROOM CEILING BOWING. IN NEED OF REPAIR.
BROKEN WINDOW GLASS.
FRONT DOOR FALLING OFF HINGES.
HOLES IN SHEETROCK THROUGHOUT UNIT.
MISSING CONVENIENCE OUTLET AND SWITCH COVER PLATES MISSING THROUGHOUT UNIT.
LIVING ROOM CIRCUIT TESTS REVERSE POLARITY.
THERMOSTAT DAMAGED.
FURNACE IN NEED OF SERVICE. CEILING IN MECHANICAL FALLING.
BROKEN WINDOW GLASS NORTH BEDROOM WINDOW.
NORTH BATHROOM POCKET DOOR DOES NOT OPERATE.
BEDROOM DOORS HAVE HOLES AND ARE OFF HINGES.
JUNK AND DEBRIS REAR YARD AREA.
REAR DOOR COMING OFF TOP HINGE.
KITCHEN COUNTER TOP LOOSE FROM CABINETS.


UNIT # 738 FOUND:
FRONT EXTERIOR DOORJAMB BACKSET NEEDS ADJUSTMENT. JAMB MISSING STRIKE PLATE AT DEAD BOLT AT JAMB.
THERMOSTAT MISSING AT LIVING ROOM WALL.
LIVING ROOM WINDOW DOES NOT LOCK.
MECHANICAL ROOM DOOR REMOVED.
REAR DOOR WEATHER STRIP NEEDS ADJUSTMENT.
KITCHEN CABINETS IN NEED OF REPAIR. MISSING DRAWERS AND DOORS.
EXTENSION CORD FROM KITCHEN TO BEDROOM CONNECTED TO SPACE HEATER.
REAR YARD JUNK AND DEBRIS.
HOLES IN SHEETROCK AND INTERIOR DOORS THROUGHOUT UNIT.
BATHROOM CEILING NOT MAINTAINED FREE FROM MILDEW.
COMMODE NOT SECURED TO FLOOR.
HOLES IN SHEETROCK BELOW BATH VANITY.
BATH WALLS NOT FINISHED.
GFCI OUTLET ABOVE BATH VANITY FAULTY.
COOLER REGISTER IN BATHROOM NOT SECURED TO WALL.
SOUTH BEDROOM EXPOSED WIRING IN CLOSET CEILING.
MISSING SHEETROCK AT POCKET DOOR.
HOLES IN BATHROOM WALLS AND BEHIND COMMODE.
COOMODE NOT SECURED TO FLOOR.
BATH VANITY BASE DETERIORATED.
EXHAUST FAN DOES NOT OPERTAE.
03/08/2004 INSP - INITIAL CODE ENFORCMENT Correction Required COMPLETED RESEARCH AT DEVELOPMENT SERVICES DEPARTMENT FOR SCHEDULED INSPECTION ON 3/09/04 WITH TFD INDPECTOR STEVE RUETZ AND PASTOR RANDY LYONS AND MANAGER OF PROPERTY. CONTACTED HEATHER THRAHL FROM ZONING FOR INFORMATION ON CASE SHE HAS OPEN ON SITE. SHE BELIEVES UNITS ON SITE ARE INDIVIDUAL APARTMENTS NOT BOARDING HOUSE SET UP. SHE CURRENTLY HAS OPEN VIOLATIONS ON A COMMERCIAL OVERSIZE BUS WHICH MUST BE REMOVED FROM PREMISES. QUANZITE HUT MUST BE REMOVED FROM PROPERTY. SHE BELIEVES PROPERTY IS BEING USED AS A RENTAL PROPERTY AND NOT A CHURCH. THERE IS AN APPROVED C OF O FOR AN APARTMENT COMPLEX. RESEARCH ALSO DONE ON INTERNET FOR PROPERTY USAGE.HEATHER THRAHL DID NOT ENTER ANY UNITS WHILE ON SITE BECAUSE OF POSSIBLE 5 HIGH LEVEL SEX OFFENDERS LIVING OF SITE SUPERVISED.
INSPECTOR STEVE RUETZ WILL FAX INSPECTOR CAMACHO A COPY OF HIS INSPECTION REPORT FOR FILE.