Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

02/11/2004

Applicant:

BELL DEAN & HANSEN SANDRA M CP/RS

Description:

COMPLAINT:MIN HOUSING-ROOF LEAKS. BROKEN WINDOWS. IMPROPER WEATHER SEALS. HIGH GAS BILL. INSTALLED A NEW HEATER BUT THERMOSTAT NOT WORKING PROPERLY

Outstanding Inspections

Case Number: T04DV00131
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
05/24/2004 INSP - INITIAL CODE ENFORCMENT HLOPEZ Violation STRUCTURE IN VACANT & SECURED VISITED SITE, FRONT GATE WAS LOCKED & NO ENTRY TO FRONT DOOR. NO TRESSPASSING SIGNS POSTED ON NORTH SIDE WINDOW. NORTH SIDE OF PROPERTY IS ACCESSABLE FROM APT. COMPLEX ON NORTHSIDE. EXTERIOR VIOLATIONS FOUND. PLUMBING (1) HOTWATER TANK LACKING B-VENT SYSTEM & DRAIN FOR TRP VALVE. STRUCTURAL (1) DELAPATED & DETERIORATED FRONT PORCH ATTACHED TO MAIN STRUCTURE, PORCH STRUCTURE EXHIBITS SIGNS OF IMENIATE DANGER, EVIDENCED BY LEAGER BOARD COMING AWAY FROM MAIN STRUCTURE. SURPPORT BEAM APPROX. 2 INCH BY 6 INCH IS SAGGING OUT OF PLUMB APPROX 4 INCHES IN A SPAN OF APPROX. 12 FEET.USE OF 2 INCH BY 4 INCH BOARDS USED TO SPAN APPROX. 8 FEET IS EVIDENCE OF IMPROPER INSTALLATION & NO INSPECTION. WEATHER PROOFING 3 INCH HOLE FOUND ON NORTH WALL OUTSIDE OF KITCHEN. NUISANCE- ACCUMALATED DEBRIS SUCH AS COIN OPERATED DRYERS & WASHING MACHINES, COUCHES, BED SPRING & OTHER MICS. ITEMS. HAZARDOUS ELECTRICAL (1) EXPOSED ELECTRICAL CONDUCTORS LACKING PROTECTION AT EAST WALL BY MAIN DISCONNECTS & MISSING BLANKS COVERS. PICTURES WERE TAKEN. NOV TO BE ISSUED AFTER RESEARCH IS DONE. APPROX 2 WEEKS. DO 14 DAY FOLLOW UP.

Completed Inspections

Case Status: COMPLIAN
Case Number: T04DV00131
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
06/09/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VIOLATIONS ABATED VISITED SITE ON FOLLOW UP INSPECTION. DELAPATED PORCH STRUCTURE HAS BEEN REMOVED, 3 INCH HOLE HOLE ON KITCHEN WALL HAS BEEN SEALED. EXPOSED ELECTRICAL CONDUCTIRS HAVE BEEN REMOVED & B-VENT SYSTEM HAS BEEN INSTALLED AT EXTERIOR HOT WATER HEATER. DUE TO STRUCTURE BEING VACANT & SECURED & AMOUNT OF BACK LOG NO NOV WAS ISSUED. OWNER HAS COMPLIED CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T04DV00131
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
05/26/2004 CONTACTED BY PHONE
05/26/2004 COURT ORDERED ABATEMENT