Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/05/2003

Applicant:

BRANSTETTER JOSEPH

Description:

COMPLAINT:MIN HOUSING-WATER LEAK IN LIVINGROOM/UNIT #2 HEATER NOT WORKING PROPERLY, LEAKING PROPANE-CEILING HAS HOLES FALLING. IMPROPER WEATHER SEALS

Outstanding Inspections

Case Number: T03DV01188
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
02/13/2004 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required UNIT 2, INT. INSP. 2/18/04, VISITED SITE, TOOK PICTURES, FOUND 20 UNITS ON SITE, MOBILE HOME PARK, TALKED WITH MARCELL WHO IS BOYFRIEND OF CAROL WHO IS OCCUPANT, MARCELL DID TALK TO ME ABOUT ISSUES OF PROPANE, MARCELL CALLED CAROL WHO WILL BE HOME IN A COUPLE OF MINUTES, AT THIS TIME I DID NOT SMELL ANY PROPANE IN THE MOBILE HOME, HEATER IS TURNED OFF AT THIS TIME, I DID NOT OPEN VALVE OR START HEATER, I DID TRY THE STOVE AND STOVE DOES LIGHT, SO THERE IS PROPANE IN TANK, MARCELL STATED THAT THEY USE STOVE AND PORTABLE SPACE HEATER FOR HEAT, I EXPLAINED TO MARCELL THAT STOVE EMITS C/O AND NOT TO DO THIS, ALSO SPACE HEATERS CAN CAUSE FIRES, AND NOT TO USE THEM EITHER, NEEDS TO CHECK AND OR REPAIR PERMANENT HEATER, CHECKED ELECTRIC SERVICE OUTSIDE AND FOUND CONVENIENCE OUTLET MISSING FROM DEAD PLATE AND OPEN AND EXPOSED WIRING, LIFE LINE CORD APPEARS TO BE SPLICED AND TAPED, ALSO MISSING KNOCK OUT PLUG ON TOP OF SERVICE BOX, INTERIOR CONVENIENCE OUTLETS ON SOUTH WALL SHOWS OPEN GROUND, MOST OF WHAT COULD BE CHECKED ARE LOOSE AND WORN INSIDE AND HAVE TO WIGGLE PLUG TO MAKE CONTACT. KITCHEN REFRIGERATOR DOORS DOES NOT SEAL PROPERLY LEAVING A GAP, ALLOWING ALL COLD AIR TO ESCAPE, REFRIGERATOR DOOR HANDLE MISSING, HALL WAY CEILING SHOWS EVIDENCE OF ROOF LEAK, RESIDENT STATED ROOF LEAKS WHEN IT RAINS, COOLER HAS BEEN REMOVED, COVERED HOLE WITH PIECE OF METAL, RAIN LEAKED AROUND WINDOWS EVIDENCE BY DETERIORATING DRYWALL, RESIDENT STATED THAT SHE HAD LIGHT A CANDLE AND HELD BY WINDOW AND THE WIND BLEW OUT CANDLE, HOT WATER TANK, PART OF DOOR MISSING AT BOTTOM AND ALSO HAS EXPOSED ROMEX LAYING ON DOOR JAMB. INTERIOR REAR DOOR HAS HAD GLASS REMOVED AND COVERED WITH SHEET OF METAL, DOOR HANDLE IS DEAD BOLT, N/O TO FOLLOW.

Completed Inspections

Case Status: COMPLIAN
Case Number: T03DV01188
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/23/2004 INSP - FOLLOW UP CODE ENFORCE JHURD Approved 3/23/04, ALL UNITS: REVISITED SITE TOOK PICTURES, ALL UNIT TO BE INSP. TODAY, ALL RENTALS. UNIT 1 EXTERIOR: BLOCK WALL GOING AROUND PROPERTY IN FRONT OF UNIT 1 HAS ELECTRICAL WIRING STICKING UP OUT OF PILLERS, WIRING FOR EXTERIOR LIGHTING NO LIGHTING FIXTURES IN PLACE, LEAVING EXPOSED WIRING, SERVICE PEDESTAL SHOWING 30 AMP BREAKER DOES NOT MATCH INTERIOR SUB PANEL, REAR DOOR DOOR TO MOBILE HOME SCREWED SHUT DUE TO BROKEN DOOR HANDLE, CAUSING EGRESS ISSUES, BATHROOM WINDOW DOES NOT OPEN CAUSING VENTILATION ISSUE, BATHROOM SINK HAS NO P-TRAP INSTALLED, CONVENIENCE OUTLET IN 1ST BEDROOM IS HOT TO THE TOUCH, POSSIBLE TO MUCH AMP DRAW, 1 BATHROOM LIGHT FIXTURE INSTALLED WIRED WRONG, SUB PANEL UNDER KITCHEN SINK DOUBLED LUGGED, SPLICED WIRING WITH WIRE NUTS ON INTERIOR OF PANEL, ADDED CIRCUITS, EXPOSED WIRING TO STOVE AND HOT WATER TANK, NO PERMITS ON FILE EVIDENCE BY INSTALLATION, LIVING ROOM CEILING SAGGING FROM OLD WATER LEAK, HOT WATER TANK HAS BEEN INSTALLED WITH OUT PERMITS, EVIDENCE BY INSTALLATION, HAS EXPOSED WIRING AT TANK CONNECTIONS IN FRONT NO SHUT OFF VAVLE TO HOT WATER TANK, UNIT 2 ELECTRICAL PEDESTAL MISSING, CONVENIENCE OUTLET ALLOWING ACCESS INTO INTERIOR, EXPOSED ELECTRICAL WIRING, WIRES SPLICED AND WIRE NUTTED TOGETHER, KNOCK OUT PLUG MISSING, DEAD PLATE LOOSE AND NOT SECURED TO BOX, INTERIOR OUTLETS WORN AND LOOSE WILL NOT HOLD PLUG PROPERLY, SHOWS OPEN GROUND UNDER TEST, KITCHEN AND BATH NOT GFCI PROTECTED, HOT WATER TANK HAS BEEN REPLACED NO PERMIT ON FILE EVIDENCE BY INSTALLATION, HOT WATER TANK STORAGE ROOM HAS EXPOSED ELECTRICAL WIRING AT BOTTOM, ALTERATION TO STORAGE ROOM TO FIT IN HOT WATER TANK, HOT WATER TANK STORAGE ROOM DOOR MISSING BOTTOM HALF, REFRIGERATOR DOOR WILL NOT SHUT PROPERLY LEAVING A GAP OF APPOX. 1" ALONG THE SIDE, REFRIGERATOR MISSING DOOR HANDLE, STOVE MISSING CONTROL TEMP. KNOB TO OVEN, FRONT PORCH DETERIORATED STRENGHT HAS BEEN COMPERMISED, PERMANENT SOURCE OF HEAT NOT OPERATING PROPERLY AS INTENDED, HOT WATER TANK HAS BEEN REPLACED NO PERMIT ON FILE EVIDENCE BY INSTALLATION, FLUE PIPE NOT CONNECTED TO HOT WATER TANK. UNIT 3 SERVICE PANEL FRONT DEAD PLATEOFF, HAS ELECTRICAL CONDUCTORS QUAD LUGGED (4) ON LOAD SIDE, HAZARDOUS, ALL FOUR GO INTO GROUND DO NOT KNOW WHERE THEY GO, CONVENIENCE OUTLET IN BEDROOM SHOWS REVERSED POLARITY, INTERIOR SUB PANEL SHOWS DOUBLEING LUGGING, REAR DOOR IN MOBILE HOME HAS PAD LOCK DUE TO HANDLE DOES NOT WORK PROPERLY, EGRESS ISSUE, CEILING BY COOLER IN NEED OF REPAIR DUE TO OLD WATER LEAK, BATH SHOWER WALLS DETERIORATED DUE TO WATER LEAKING INBEHIND, CONVENIENCE OUTLET BY TOILET NEEDS TO BE GFCI PROTECTED, BATHROOM WINDOW WILL NOT OPEN, VENTILATION ISSUE, EXPOSED WIRING AT LIGHT FIXTURE, USING EXTENSION CORD TO SUPPLY POWER TO LIGHT FIXTURE IN LIEU OF PERMANENT WIRING, COOLER HAS EXPOSED WIRING, MISSING DIFFUSER SLATS TO DIRECT AIR FLOW, KITCHEN 2 GFCI CONVENIENCE OUTLETS SHOWING OPEN GROUND UNDER TEST, DO NOT WORK, CONVENIENCE OUTLET ON EXTERIOR NORTH SIDE NOT WEATHER PROTECTED, AFTER SEEING ALL ELECTRICAL HAZARDS AT PEDESTAL AT INTERIOR SUB PANEL I EXPLAINED TO OWER JOSPH HE WOULD NEED TO CALL HIS ELECTRICAN AND HAVE THIS LOOKED AT TODAY, HE DID CALL ELECTRICAN AND ELECTRICAN WOULD BE OUT TODAY I DID TALK TO ELECTRICAN TO EXPLAIN ISSUES AND HAZARDS. ELECTRICAN STATED HE WOULD BE OUT TODAY. UNIT 4

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV01188
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
09/13/2004 CONTACTED BY PHONE
06/08/2004 NOTICE OF VIOLATION ISSUED
06/08/2004 COURT ORDERED ABATEMENT
02/13/2004

Documents

File Name Document Type  
MVC-760S.JPG IMAGES VIEW
MVC-761S.JPG IMAGES VIEW
MVC-762S.JPG IMAGES VIEW
MVC-763S.JPG IMAGES VIEW
MVC-764S.JPG IMAGES VIEW
MVC-765S.JPG IMAGES VIEW
MVC-766S.JPG IMAGES VIEW
MVC-366S.JPG IMAGES VIEW
MVC-367S.JPG IMAGES VIEW
MVC-368S.JPG IMAGES VIEW
MVC-369S.JPG IMAGES VIEW
MVC-370S.JPG IMAGES VIEW
MVC-371S.JPG IMAGES VIEW
MVC-372S.JPG IMAGES VIEW
MVC-373S.JPG IMAGES VIEW
MVC-374S.JPG IMAGES VIEW
MVC-375S.JPG IMAGES VIEW
MVC-376S.JPG IMAGES VIEW
MVC-377S.JPG IMAGES VIEW
MVC-378S.JPG IMAGES VIEW
MVC-379S.JPG IMAGES VIEW
MVC-380S.JPG IMAGES VIEW
MVC-381S.JPG IMAGES VIEW
MVC-382S.JPG IMAGES VIEW
MVC-383S.JPG IMAGES VIEW
MVC-384S.JPG IMAGES VIEW
MVC-385S.JPG IMAGES VIEW
MVC-386S.JPG IMAGES VIEW
MVC-387S.JPG IMAGES VIEW
MVC-388S.JPG IMAGES VIEW
MVC-389S.JPG IMAGES VIEW
MVC-390S.JPG IMAGES VIEW
MVC-391S.JPG IMAGES VIEW
MVC-392S.JPG IMAGES VIEW
MVC-393S.JPG IMAGES VIEW
MVC-394S.JPG IMAGES VIEW
MVC-395S.JPG IMAGES VIEW
MVC-396S.JPG IMAGES VIEW
MVC-397S.JPG IMAGES VIEW
MVC-398S.JPG IMAGES VIEW
MVC-399S.JPG IMAGES VIEW
MVC-400S.JPG IMAGES VIEW
MVC-401S.JPG IMAGES VIEW
MVC-402S.JPG IMAGES VIEW
MVC-403S.JPG IMAGES VIEW
MVC-404S.JPG IMAGES VIEW
MVC-405S.JPG IMAGES VIEW
MVC-406S.JPG IMAGES VIEW
MVC-407S.JPG IMAGES VIEW
MVC-408S.JPG IMAGES VIEW
MVC-409S.JPG IMAGES VIEW
MVC-410S.JPG IMAGES VIEW
MVC-411S.JPG IMAGES VIEW
MVC-412S.JPG IMAGES VIEW
MVC-413S.JPG IMAGES VIEW
MVC-414S.JPG IMAGES VIEW
MVC-415S.JPG IMAGES VIEW
MVC-416S.JPG IMAGES VIEW
MVC-417S.JPG IMAGES VIEW
MVC-418S.JPG IMAGES VIEW
MVC-419S.JPG IMAGES VIEW
MVC-420S.JPG IMAGES VIEW
MVC-421S.JPG IMAGES VIEW
MVC-422S.JPG IMAGES VIEW
MVC-423S.JPG IMAGES VIEW
MVC-424S.JPG IMAGES VIEW
MODIF NOTICE FOR HECTOR.PDF DOCUMENTS VIEW
NOV-NPO-DNR (A0003314).DOC#1.PDF DOCUMENTS VIEW