Inspection History Details
Inspection Status: Compliance
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T03DV01188
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Compliance
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/14/2005 | INSP - FOLLOW UP CODE ENFORCE | Compliance | 1/14/05, PROPERTY IS IN COMPLIANCE AT THIS TIME, ALL ISSUES ON N/O HAS BEEN COMPLETED COMPLIANCE CLOSE CASE. | |
| 01/05/2005 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 1/4/05, REVISITED SITE, DONE F/U INSP. MET WITH JOESPH AND MITZI, AND JIM WALKED PROPERTY AND INTERIORS OF ALL UNITS, ALL ELECTRIC ON SITE HAS BEEN REDONE ALL UPGRADED, PERMITS IN FILE, SOME SMALLER ISSUES HAS NOT BEEN ADDRESSED WILL FAX COPY OVER TO JOSEPH SCHEDULED ANOTHER F/U VISIT FOR 1/14/05 WHICH ALL ISSUES WILL BE COMPLETED. | |
| 03/23/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 3/23/04, ALL UNITS: REVISITED SITE TOOK PICTURES, ALL UNIT TO BE INSP. TODAY, ALL RENTALS. UNIT 1 EXTERIOR: BLOCK WALL GOING AROUND PROPERTY IN FRONT OF UNIT 1 HAS ELECTRICAL WIRING STICKING UP OUT OF PILLERS, WIRING FOR EXTERIOR LIGHTING NO LIGHTING FIXTURES IN PLACE, LEAVING EXPOSED WIRING, SERVICE PEDESTAL SHOWING 30 AMP BREAKER DOES NOT MATCH INTERIOR SUB PANEL, REAR DOOR DOOR TO MOBILE HOME SCREWED SHUT DUE TO BROKEN DOOR HANDLE, CAUSING EGRESS ISSUES, BATHROOM WINDOW DOES NOT OPEN CAUSING VENTILATION ISSUE, BATHROOM SINK HAS NO P-TRAP INSTALLED, CONVENIENCE OUTLET IN 1ST BEDROOM IS HOT TO THE TOUCH, POSSIBLE TO MUCH AMP DRAW, 1 BATHROOM LIGHT FIXTURE INSTALLED WIRED WRONG, SUB PANEL UNDER KITCHEN SINK DOUBLED LUGGED, SPLICED WIRING WITH WIRE NUTS ON INTERIOR OF PANEL, ADDED CIRCUITS, EXPOSED WIRING TO STOVE AND HOT WATER TANK, NO PERMITS ON FILE EVIDENCE BY INSTALLATION, LIVING ROOM CEILING SAGGING FROM OLD WATER LEAK, HOT WATER TANK HAS BEEN INSTALLED WITH OUT PERMITS, EVIDENCE BY INSTALLATION, HAS EXPOSED WIRING AT TANK CONNECTIONS IN FRONT NO SHUT OFF VAVLE TO HOT WATER TANK, UNIT 2 ELECTRICAL PEDESTAL MISSING, CONVENIENCE OUTLET ALLOWING ACCESS INTO INTERIOR, EXPOSED ELECTRICAL WIRING, WIRES SPLICED AND WIRE NUTTED TOGETHER, KNOCK OUT PLUG MISSING, DEAD PLATE LOOSE AND NOT SECURED TO BOX, INTERIOR OUTLETS WORN AND LOOSE WILL NOT HOLD PLUG PROPERLY, SHOWS OPEN GROUND UNDER TEST, KITCHEN AND BATH NOT GFCI PROTECTED, HOT WATER TANK HAS BEEN REPLACED NO PERMIT ON FILE EVIDENCE BY INSTALLATION, HOT WATER TANK STORAGE ROOM HAS EXPOSED ELECTRICAL WIRING AT BOTTOM, ALTERATION TO STORAGE ROOM TO FIT IN HOT WATER TANK, HOT WATER TANK STORAGE ROOM DOOR MISSING BOTTOM HALF, REFRIGERATOR DOOR WILL NOT SHUT PROPERLY LEAVING A GAP OF APPOX. 1" ALONG THE SIDE, REFRIGERATOR MISSING DOOR HANDLE, STOVE MISSING CONTROL TEMP. KNOB TO OVEN, FRONT PORCH DETERIORATED STRENGHT HAS BEEN COMPERMISED, PERMANENT SOURCE OF HEAT NOT OPERATING PROPERLY AS INTENDED, HOT WATER TANK HAS BEEN REPLACED NO PERMIT ON FILE EVIDENCE BY INSTALLATION, FLUE PIPE NOT CONNECTED TO HOT WATER TANK. UNIT 3 SERVICE PANEL FRONT DEAD PLATEOFF, HAS ELECTRICAL CONDUCTORS QUAD LUGGED (4) ON LOAD SIDE, HAZARDOUS, ALL FOUR GO INTO GROUND DO NOT KNOW WHERE THEY GO, CONVENIENCE OUTLET IN BEDROOM SHOWS REVERSED POLARITY, INTERIOR SUB PANEL SHOWS DOUBLEING LUGGING, REAR DOOR IN MOBILE HOME HAS PAD LOCK DUE TO HANDLE DOES NOT WORK PROPERLY, EGRESS ISSUE, CEILING BY COOLER IN NEED OF REPAIR DUE TO OLD WATER LEAK, BATH SHOWER WALLS DETERIORATED DUE TO WATER LEAKING INBEHIND, CONVENIENCE OUTLET BY TOILET NEEDS TO BE GFCI PROTECTED, BATHROOM WINDOW WILL NOT OPEN, VENTILATION ISSUE, EXPOSED WIRING AT LIGHT FIXTURE, USING EXTENSION CORD TO SUPPLY POWER TO LIGHT FIXTURE IN LIEU OF PERMANENT WIRING, COOLER HAS EXPOSED WIRING, MISSING DIFFUSER SLATS TO DIRECT AIR FLOW, KITCHEN 2 GFCI CONVENIENCE OUTLETS SHOWING OPEN GROUND UNDER TEST, DO NOT WORK, CONVENIENCE OUTLET ON EXTERIOR NORTH SIDE NOT WEATHER PROTECTED, AFTER SEEING ALL ELECTRICAL HAZARDS AT PEDESTAL AT INTERIOR SUB PANEL I EXPLAINED TO OWER JOSPH HE WOULD NEED TO CALL HIS ELECTRICAN AND HAVE THIS LOOKED AT TODAY, HE DID CALL ELECTRICAN AND ELECTRICAN WOULD BE OUT TODAY I DID TALK TO ELECTRICAN TO EXPLAIN ISSUES AND HAZARDS. ELECTRICAN STATED HE WOULD BE OUT TODAY. UNIT 4 |
|
| 03/15/2004 | INSP - FOLLOW UP CODE ENFORCE | Correction Required | 3/9/04, REVISITED SITE, MET WITH INSPECTOR CAMACHO AND INSPECTOR LOPEZ ON SITE, WE WERE TO MEET WITH ELECTRICAL INSPECTOR MAC FROM D.S.D. MAC DID NOT SHOW, ALSO ON SITE WAS OWNER JOSEPH AND MANAGER MITZI, I DID TALK WITH OWNER AND MANAGER AND STATED THAT I WOULD NEED TO GET INTO ALL UNITS ON SIGHT, HE STATED THIS WOULD NOT BE A PROBLEM BUT NEEDED AN LITTLE TIME TO MAKE ALL ARRANGEMENTS WITH RESIDENTS, ALSO INSP. LOPEZ HAS OWNER OF PROPERTY ON N/O FOR OTHER SIDE (SABER) I EXPLAINED TO JOSEPH THAT I WOULD GIVE HIM UNTIL APPOX 3/23 TO MAKE ALL ARRANGEMENTS TO DO INSP. AND THEN IT WOULD TAKE A LITTLE TIME TO DO N/O, THIS WOULD GIVE HIM ENOUGH TIME TO WORK ON INSP. LOPEZ'S N/O. D.S.D STATED TO CONTRACTOR THAT NO SPACING EXIST AT THIS ADDRESS AND COULD NOT GET PERMIT FOR INSTALLATION OF NEW HEATER IN UNIT # 2, I EXPLAINED TO OWNER THAT I WOULD DO RESEARCH ON PROPERTY AND FOR CONTRACTOR TO WAIT UNTIL I FIND OUT WHAT IS GOING ON, I WOULD STILL NEED PERMIT BUT IT'S OK UNTIL I FIND OUT WHY THERE IS NO ADDRESSING OR SPACES ON SITE. F/U 3/23/04. |