Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

08/01/2003

Applicant:

CHRISTIE BRIAN & LAURA H A JT/RS

Description:

COMPLAINT:MIN HOUSING-CEILING DAMAGE. OTHER ISSUES. 01/08/04 - VACANT AND UNSECURED, UNITS TRASHED. 07/22/04 #106 - NO WATER IN SHOWER FOR 2 WEEKS. NO WATER PRESSURE.

Outstanding Inspections

Case Number: T03DV00707
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
08/07/2003 INSP - INITIAL CODE ENFORCMENT HLOPEZ Correction Required VISITED SITE, WALKED PROPERTY WITH MANAGER. VIOLATIONS FOUND ARE: APT #102-- 1) SMOKE DETECT0R HAS BEEN REMOVED 2) WEATHER STRIPPING LACKING FROM ENTRY DOOR & THOW HAS BEEN DAMAGED 3) HARDWARE ON WEST BEDROOM DOOR IS REVERSED (PRIVACY LOCK) 4) 2 HOLES IN BATHROOM CEILING APPROX 16" X 14" & 6" X 6" 5) PLUMBING LEAKING UNDER BOTH KITCHEN & BATHROOM SINKS. APT 112 -- 1) ENTRY DOOR LACKING STRIKER PLATE & WEATHER STRIPPING 2) CEILING HAS DAMAGED FROM LEAK IN ROOF. ROOF WORK SCHEDULED TO START ON APPROX 8/15/03. ALSO A HOLE IN BATHROOM FLOOR APPROX. 3" ROUND. 3) STORAGE CLOSET HARDWARE LOOSE 4) KITCHEN CABINETS HAS DRAW STILE HAS BEEN BROKEN, CABINET DOOR HAS COME AWAY FROM HINGE. PICTURES WERE TAKEN. SMOKE DETECTOR NOT WORKING. GUARD RAILING LOOSE ON SOUTH END OF LANDING OUTSIDE OF UNIT 112 & 111. ATTEMPTED CONTACT WITH APT. 111 NO ONE HOME LEFT CARD & REQUESTED CALL FOR SCHEDULING OF INSPECTION. LAUNDRY ROOM: 1) LIGHT FIXTURE LACKING COVERS FOR FLUORESCENT BULBS & HAZARDOUS ELECTRICAL, ILLEGALLY SPLICED ELECTRICAL CONDUCTOR FOR WALL LIGHT FIXTURE.

Completed Inspections

Case Status: COMPLIAN
Case Number: T03DV00707
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
01/26/2004 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VIOLATIONS ABATED MET COMPLEX MANAGER ON SITE FOR FW/UP INSPECTIONS UNIT 102 1) SMOKE DETECTOR CHECKED & FOUND WORKING 2) WEATHER STRIPPING & THOW HAS BEEN REPLACED 3) HARDWARE HAS BEEN CORRECTED FOR BEDROOM DOOR. 4) HOLES IN CEILING HAVE BEEN REPAIRED 5) PLUMBING LEAKS UNDER KITCHEN & BATHROOM SINKS HAVE BEEN REPAIRED. APT. HAS BEEN REHABED OWNER HAS COMPLIED CLOSE THIS PART OF CASE. UNIT 112 1) STRIKER PLATE & WEATHER STRIPPING HAVE BEEN REPLACED. 2) CEILING DAMAGE HAS BEEN REPAIRED, TEXTURED & REPAINTED 3) 3" HOLE IN BATH ROOM FLOORING WAS REPAIRED. 4) HARDWARE FOR CLOSET SECURED 5) KITCHEN DRAWER STILE WAS REPAIRED & CABINET DOOR RESECURED TO HINGE. 6) SMOKE DETECTOR WAS CHECKED & WAS FOUND WORKING. APT. HAS BEEN REHABED, OWNERS HAVE COMPLIED CLOSE THIS PART OF CASE. GARD RAILS GARD RAILS HAVE BEEN RESECURED TO WALL BY UNITS 112 & 111. UNIT 111 IS VACANT & SECURED. CITY HAS NO JURIDICTION ON VACANT & SECURE STRUCTURE CLOSE THIS PART OF CASE. LAUNDRY ROOM 1) NEW LIGHT FIXTURE HAS BEEN INSTALLED 2) ILLEGALLED SPLICED ELECTRICAL CONDUCTORS FOR WALL LIGHT FIXTURE WERE REMOVED. OWNER HAS COMPLIED CLOSE CASE LATE ENTRY OF NOTES DUE TO EXISTING PACKET HAD BEEN MISPLACED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00707
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
08/26/2003 CONTACTED BY PHONE