Applicant:
HARBOUR PARTNERS LTD
Description:
COMPLAINT:MIN HOUSING-SHOWER LEAKS
Outstanding Inspections
Case Number: T03DV00022
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/14/2003 | INSP - INITIAL CODE ENFORCMENT | JHURD | Correction Required | 1/13/03, VISITED SITE, TOOK PICTURES, MET WITH RESIDENT LEANNE, LEANNE HAD SHOWED WHERE THE SHOWED LEAKS EVERY TIME SHE TAKES A SHOWER, WATER LEAKS IN WALL, AND FLOOR, IT GETS THE CARPET WET IN HALL WAY AND OUT INTO LIVING ROOM, RESIDENT CALLED MGMT. AND MAINTENANCE CAME OUT AND WET VAC. CARPET BUT DID NOT DO ANY FOR THE LEAK, WHEN RESIDENT SHOWERS THE CARPET GETS WET AGAIN, ALL SO FOUND THAT THE CONVIENCE OUTLETS THROUGH OUT THE UNIT ARE WORN AND WILL NOT HOLD PLUGS, THESE WILL ALSO INCLUDE THE ONES IN THE KITCHEN AND BATH THESE WILL NEED TO BE REPLACED WITH GFCI'S, TALKED WITH MGMT. AND WILL GET RIGHT ON THESE ISSUES, I EXPLAINED ABOUT THE REPLACEMENT OF GFCI IN KITCHEN AND BATH. N.O. TO FOLLOW 30 DAY F/U |
Completed Inspections
Case Status: COMPLIAN
Case Number: T03DV00022
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/07/2003 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | 3/7/03, REVISITED SITE, TOOK PICTURES, MET WITH RESIDENT AND SHE STATED THAT THEY DID COME BUT ONLY DONE ELECTRICAL WORK, WENT TO OFFICE TO TALK WITH MGMT. MGMT. WAS NOT IN OFFICE BUT DID MAKE CONTACT BY PHONE AND SHE STATED THAT SHE HAD THOUGHT EVERY THING WAS DONE, I STATED THAT RESIDENT STATED THAT THEY ONLY DONE ELLECTRICAL WORK, SHE THEN CALLED HER MAINTENANCE SUPVISOR WHO STATED THAT ALL WORK HAS BEEN COMPLETED, HE IN TURN CALLED ME AND EXPLAINED WHAT WAS DONE, I MET HIM ON SITE AND HE SHOWED WHERE THE LEAK WAS COMMING FROM AND HE MADE REPAIRS, RESIDENT SAID BECAUSE THE CARPET WAS STILL WET, IT WILL TAKE A COUPLE OF DAYS FOR CARPET TO DRY, MAIN. SUP. DID WET VAC. CARPET AND DISINFECTED CARPET, LEAK CAME FROM WAX RING UNDER TOILET. ALL ISSUES HAS BEEN ABATED. COMPLIANCE. CLOSE CASE |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T03DV00022
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date | Name |
01/15/2003 | NOTICE AND ORDER ISSUED |