Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

COM: FIRE

Entered Date:

08/20/2001

Applicant:

MUNGIA FREDERICO

Description:

EMERGENCY CALL OUT FIRE

Completed Inspections

Case Status: COMPLIAN
Case Number: T01VL02390
Case Description: COM: FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/17/2001 INITIAL CODE VIOLATION RHOLLAND Approved NOTICE OF VIOLATION UNSAFE CONDITIONS 1.) DOUBLE LUGGING OF CONDUCTORS UNDER TEMANALS 2.) NO FUSE PROTECTION FOR CONDUCTORS 3.) IMPROPER CLEARENCE OF LUGS TO ENCLOUSER DUCT TAPE INSULATION NOT ALLOWED. 4.) COMBUSTIBLE MATERIAL INSIDE DISCONNECT 5.) DISCONNECT IN POOR SHAPE. 6.) ENTRANCE CONDUCTOR IN CONTACT WITH METAL PORCH OVERHEAD CLEARENCES NOT TO CODE. 7.) NEED GENERAL REPAIR PERMIT TO REPAIR PORCH 8.) EXPOSED ROMEX WIRING. SENT N.O.V. ON 8/21/01 RECEIVE CERTIFIED 8/24/01 FU. 9/21/01
11/09/2001 FOLLOW UP CODE VIOLATION MCAPISTR Approved REPAIRS COMPLETED UNDER SEPARATE PERMIT.

Completed Activity Special Conditions

Case Description - COM: FIRE
Case Number - T01VL02390
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
08/20/2001 SITE VISIT/INSPECTION MADE. SEE INSPECTION RESULTS AND NOTATIONS FOR SPECIFIC INFORMATION.
03/16/2009 VIOLATION CLOSED.

Documents

File Name Document Type  
None DOCUMENTS VIEW