End Date Description Inspector Results Comments
09/17/2026 COT - ENFC - Code Enforcement - Initial In Violation Arrived on scene at 11:09 PM. Per TFD, the fire was started in the bedroom in the Southwest corner of the home. The fire was believed to have been started by squatters inside the structure as the home was previously condemned. In addition, lighters and drug paraphernalia, as well as debris consistent with homeless and squatting activity was found in the room. The roof was not breached by TFD. On the east side of the structure, the two front rooms sustained Smoke damage throughout. The ceiling is cut down in multiple areas. There is an electrical line cut in the room at the north east corner of the structure where a window swamp cooler was previously installed. In the Southwest corner bedroom, the window is removed, was previously boarded. There is damage to the stucco and underlying Adobe loadbearing wall, as an approximately 1 foot wide by 3 foot tall section of Adobe is missing. The roof structural members are damaged and splintered as well as fire damaged in this room. The electrical devices are burned. The visible wiring in the structure is metal clad cable, and is likely heat damaged on the inside. On the west wall, the rear door is removed and Adobe wall is damaged in the area, door frame is removed. In the north west corner room, there is heavy smoke damage and drywall damage, drywall has been removed in areas. On the outside of the structure, the water heater has been knocked over onto the ground, is no longer connected. There is damaged electrical conduit which is leaving exposed conductors. The main electrical panel on the southwest corner of the structure is wet due to firefighting activities and water on breakers. The electrical meter and gas meter are both removed prior to my arrival. There are two detached structures on site and both were previously boarded, and are now breached. It is known that the property owner is in jail and as such is unable to secure his property. A city contractor was called to secure the property. ENERGOV CHARACTER LIMIT -VM

Documents

File Name Document Type  
CE-VIO0926-03904 EAOV SCAN.PDF DOCUMENTS VIEW
IMAGES 2026-09-17 CE-VIO0926-03904.PDF DOCUMENTS VIEW
TC_00597.JPG DOCUMENTS VIEW
TC_00598.JPG DOCUMENTS VIEW
TC_00599.JPG DOCUMENTS VIEW
TC_00600.JPG DOCUMENTS VIEW
TC_00601.JPG DOCUMENTS VIEW
TC_00602.JPG DOCUMENTS VIEW
TC_00603.JPG DOCUMENTS VIEW
TC_00604.JPG DOCUMENTS VIEW
TC_00605.JPG DOCUMENTS VIEW
TC_00606.JPG DOCUMENTS VIEW
TC_00607.JPG DOCUMENTS VIEW
TC_00608.JPG DOCUMENTS VIEW
TC_00609.JPG DOCUMENTS VIEW
TC_00610.JPG DOCUMENTS VIEW
TC_00611.JPG DOCUMENTS VIEW
TC_00612.JPG DOCUMENTS VIEW
TC_00613.JPG DOCUMENTS VIEW
TC_00614.JPG DOCUMENTS VIEW
TC_00615.JPG DOCUMENTS VIEW
TC_00616.JPG DOCUMENTS VIEW
TC_00617.JPG DOCUMENTS VIEW
TC_00618.JPG DOCUMENTS VIEW
TC_00619.JPG DOCUMENTS VIEW
TC_00620.JPG DOCUMENTS VIEW
TC_00621.JPG DOCUMENTS VIEW
TC_00622.JPG DOCUMENTS VIEW
TC_00623.JPG DOCUMENTS VIEW
TC_00624.JPG DOCUMENTS VIEW
TC_00625.JPG DOCUMENTS VIEW
TC_00626.JPG DOCUMENTS VIEW
TC_00627.JPG DOCUMENTS VIEW
TC_00628.JPG DOCUMENTS VIEW
TC_00629.JPG DOCUMENTS VIEW
TC_00630.JPG DOCUMENTS VIEW
TC_00631.JPG DOCUMENTS VIEW
TC_00632.JPG DOCUMENTS VIEW
TC_00633.JPG DOCUMENTS VIEW
TC_00634.JPG DOCUMENTS VIEW
TC_00635.JPG DOCUMENTS VIEW
TC_00636.JPG DOCUMENTS VIEW
TC_00637.JPG DOCUMENTS VIEW
TC_00638.JPG DOCUMENTS VIEW
TC_00639.JPG DOCUMENTS VIEW
TC_00640.JPG DOCUMENTS VIEW
TC_00641.JPG DOCUMENTS VIEW
TC_00642.JPG DOCUMENTS VIEW
TC_00643.JPG DOCUMENTS VIEW
TC_00644.JPG DOCUMENTS VIEW
TC_00645.JPG DOCUMENTS VIEW
TC_00646.JPG DOCUMENTS VIEW
TC_00647.JPG DOCUMENTS VIEW
TC_00648.JPG DOCUMENTS VIEW
TC_00649.JPG DOCUMENTS VIEW
TC_00650.JPG DOCUMENTS VIEW
TC_00651.JPG DOCUMENTS VIEW
TC_00652.JPG DOCUMENTS VIEW
TC_00653.JPG DOCUMENTS VIEW
TC_00654.JPG DOCUMENTS VIEW