Description:

Completed Inspections

Case Status: Active
Case Number: CE-VIO0825-03713
Case Description: Emergency / Unit Delta 21 : Building safety for fire
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/29/2025 COT - ENFC - Code Enforcement - Initial In Violation 5201 E. 2nd St, building D unit 21 T.E.P. had deactivated power to unit D21 prior to inspection. The plywood behind the energized multi main metering system is deteriorated and some of the main disconnects are only being supported loosely by its conduit. Majority of these main disconnects on this same deteriorated board are not labeled. Kitchen ceiling drywall is damaged from penetrations used for fire inspections. The kitchen and living room have endured smoke damage to include the cabinets. The kitchen light fixture endured heat and is suspended by its conductors. Behind the stove there is a power strip being used to energize the now damaged range hood. The circuit to energize the range protrudes through the wall and it’s connecting outlet is damaged. The unit has been posted unfit to occupy until all applicable permits are obtained and the necessary repairs are completed. Tenant and property management acknowledged all pertaining documents and requirements.
10/08/2025 COT - ENFC - Code Enforcement - Follow Up In Violation Unit is secured and posted unfit to occupy. The surround area has a noticeable amount of vacant units at the complex and is being painted.