Status:

Received

Type:

EMER - UNIT ON BLDG 934 (NOT 9034) THIS COMPLEX HAS AN ADDRESSING PROBLEM - TFD requesting building safety for broken fire sprinkler line causing flooding and collapsed ceilings - MAIN CASE ACTIVITIES TO BE LOGGED UNDER THIS CASE NUMBER

Entered Date:

05/08/2026

Applicant:

N/A

Description:

Completed Inspections

Case Status: Received
Case Number: CE-VIO0526-02078
Case Description: EMER - UNIT ON BLDG 934 (NOT 9034) THIS COMPLEX HAS AN ADDRESSING PROBLEM - TFD requesting building safety for broken fire sprinkler line causing flooding and collapsed ceilings - MAIN CASE ACTIVITIES TO BE LOGGED UNDER THIS CASE NUMBER
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/08/2026 COT - ENFC - Code Enforcement - Initial Completed Arrived on scene at 742 PM and TFD had already left the scene. Contractor was cutting out flooring in Unit 934 when pieces of wood struck the fire sprinkler water supply line and ruptured the pipe. Water shot up into unit 934 and soaked the kitchen area walls and there was standing water inside Unit 934. Light fixture directly above the rupture is water damaged. Water ran down the wall behind stove, GFCI outlet on this wall likely got wet. Found no breakers tripped. The subfloor OSB has an approximately 3 foot by 12 foot area cut out and there is now a hole into the floor where a person could fall into Unit 924 directly below it. Kustom Restoration company arrived on scene and secured the hole into the floor by placing plywood across the entryway to the kitchen and extracted the water. Outlet and fixture shall be replaced. Flooring shall be repaired with an issued permit within 60 days. Unit is condemned and may not be occupied until reinspected by Code Enforcement. -VM

Documents

File Name Document Type  
CE-VIO0526-02078 01 EAOV SCAN.PDF DOCUMENTS VIEW
CE-VIO0526-02078 02 NOV SCAN.PDF DOCUMENTS VIEW
CE-VIO0526-02078 03 NAO SCAN.PDF DOCUMENTS VIEW
IMAGES 2026-05-08 CE-VIO0526-02078.PDF DOCUMENTS VIEW
IMG_0636.JPG DOCUMENTS VIEW
IMG_0637.JPG DOCUMENTS VIEW
IMG_0638.JPG DOCUMENTS VIEW
IMG_0639.JPG DOCUMENTS VIEW
IMG_0640.JPG DOCUMENTS VIEW
IMG_0641.JPG DOCUMENTS VIEW
IMG_0642.JPG DOCUMENTS VIEW
IMG_0643.JPG DOCUMENTS VIEW
IMG_0644.JPG DOCUMENTS VIEW
IMG_0668.JPG DOCUMENTS VIEW
IMG_0673.JPG DOCUMENTS VIEW
IMG_0674.JPG DOCUMENTS VIEW
IMG_0675.JPG DOCUMENTS VIEW