TFD EMERGENCY CALL OUT, FIRE CALL FOR UNITS 2711 AND 2713 (DUPLEX)

Entered Date:

04/21/2025

Applicant:

N/A

Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: CE-VIO0425-01641
Case Description: TFD EMERGENCY CALL OUT, FIRE CALL FOR UNITS 2711 AND 2713 (DUPLEX)
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/21/2025 COT - ENFC - Code Enforcement - Initial Completed ON SITE WITH INSPECTOR TIDWELL, TFD, TEP, TPD AND RESIDENTS. THERE WAS A FIRE TO THE ELECTRICAL UTILITY POLE IN THE ALLEY. THE FIRE SPREAD FROM THE SERVICE POLE TO THE DETACHED, DOUBLE CARPORT OF UNITS 2711 AND 2713. THE WOOD CARPORT SUSTAINED HEAVY FIRE DAMAGE TO THE FRAMING. INCLUDING THE ROOF, WOOD BEAMS AND ELECTRICAL. THE FIRE CONTINUED TO SPREAD FROM THE ELECTRICAL POLE SERVICE LINE TO THE EVE OF THE ATTACHED BLOCK AND STUCCO UNITS OF 2711 AND 2713. THE EXPOSED EXTERIOR WIRING AT THE EVES OF THE REAR OF THE UNITS, WAS DIRECTLY ABOVE THE SERVICE PANELS, OF BOTH UNITS 2711 AND 2713. THE EVE SHOWED. HEAT AND FIRE DAMAGE. THERE WAS POSSIBLE HEAT DAMAGE FROM THE FIRE TO THE WEATHER HEAD. THE SERVICE PANEL, WEATHER HEAD, EVES, ROOF LINE, AND GROUND WERE SATURATED WITH WATER. FROM TFD EFFORTS TO CONTROL THE FIRE. THE INTERIOR REAR BEDROOM OF UNIT 2713 HAD EXPOSED ROMEX THAT APPEARED TO BE MELTED IN SOME AREAS AS IT ENTERED THE DWELLING FROM THE EXTERIOR PANEL. THE POSSIBLY LEAD BASED, METAL, FRAMED WINDOW HAD A BROKEN PANE. THERE WAS DRYWALL DAMAGE TO THE CEILING OF THE BEDROOM OF UNIT 2713. UNIT 2713 AND 2711 ARE CONDEMNED DUE TO FIRE/HEAT AND WATER DAMAGE AT THE AREA OF THE SERVICE PANELS AND WEATHER HEAD. PERMITS ARE REQUIRED FOR REPAIRS.
04/24/2025 COT - ENFC - Code Enforcement - Follow Up In Violation On site w/Insp. Tidwell and Morales - Reinspection was requested. Met with resident to discuss reasons why the dwelling was condemned. Explained it was due to the amount of heat, fire and water damage and how it was in the vicinity of the service panels. Advised her to utilize her contractor to assist with the permitting process.

Documents

File Name Document Type  
AAUZ3577.JPG DOCUMENTS VIEW
DBMR4260.JPG DOCUMENTS VIEW
ECPD1142.JPG DOCUMENTS VIEW
EXAK1441.JPG DOCUMENTS VIEW
FMPP2484.JPG DOCUMENTS VIEW
FWUH6633.JPG DOCUMENTS VIEW
FZNN1583.JPG DOCUMENTS VIEW
IDVN8874.JPG DOCUMENTS VIEW
JIOO2505.JPG DOCUMENTS VIEW
JYNH3652.JPG DOCUMENTS VIEW
MBLN3304.JPG DOCUMENTS VIEW
MWXY7272.JPG DOCUMENTS VIEW
OTBQ4416.JPG DOCUMENTS VIEW
QMGF3121.JPG DOCUMENTS VIEW
QOFL3514.JPG DOCUMENTS VIEW
SEAL3104.JPG DOCUMENTS VIEW
SKAN5432.JPG DOCUMENTS VIEW
TJCI1122.JPG DOCUMENTS VIEW
UYCH2831.JPG DOCUMENTS VIEW
XIIF6960.JPG DOCUMENTS VIEW
SCAN_ASANCHE2_2025-04-22-08-16-14.PDF DOCUMENTS VIEW
IMG_9608.JPG DOCUMENTS VIEW
IMG_9609.JPG DOCUMENTS VIEW
IMG_9610.JPG DOCUMENTS VIEW
IMG_9611.JPG DOCUMENTS VIEW
IMG_9612.JPG DOCUMENTS VIEW