Case: CE-VIO0424-01358
Case Details
Status:
Active
Type:
RMIN / Poor electric outlets, leaking roof, Vermin and Cockroach Infestation, Furnace does not work properly due to previous water damage from rain, Collapsing Roof and Caved in Ceiling. Bathroon walls beneath sink have water damage 02/20/2025 - New tenant calling says electric wires had a fire in the wall, back porch rotted out, no locks on front door, back door is rotted out, no smoke detectors in building, water heater room has rotted wood with "fur" on it, bathroom tub leaking, bathroom sink is clogged, broken window in kitchen, living room floor has a leak water is coming up out of the floor, bathroom door has holes in it
Address:
Entered Date:
04/15/2024
Applicant:
N/A
Description:
Completed Inspections
Case Status: Active
Case Number: CE-VIO0424-01358
Case Description: RMIN / Poor electric outlets, leaking roof, Vermin and Cockroach Infestation, Furnace does not work properly due to previous water damage from rain, Collapsing Roof and Caved in Ceiling. Bathroon walls beneath sink have water damage
02/20/2025 - New tenant calling says electric wires had a fire in the wall, back porch rotted out, no locks on front door, back door is rotted out, no smoke detectors in building, water heater room has rotted wood with "fur" on it, bathroom tub leaking, bathroom sink is clogged, broken window in kitchen, living room floor has a leak water is coming up out of the floor, bathroom door has holes in it
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/16/2024 | COT - ENFC - Code Enforcement - Initial | In Violation | 1158 AM - Called and spoke to complainant, who has moved out of property. Followup at property. Both swamp coolers at front and back unit have been removed without a Permit. Appears front house is using window AC units as primary cooling. Unable to verify a roof collapse from the street. There is an addition to the rear porch extending to the property line sometime after 2005. Knocked at front door, no ans. Left a card at front door. -VM | |
02/21/2025 | COT - ENFC - Code Enforcement - Follow Up | In Violation | 1048 AM - Met on site with tenant who provided access to home. Verified violations are as follows: 1. Deadbolt lock missing on front door 2. Front door wood missing paint, wood is rotting/exposed to elements 3. Northwest bedroom door frame missing, repair completed in a non workman like manner 4. No smoke detector northwest bedroom 5. Missing outlet covers southeast bedroom 6. Ceiling fan southeast bedroom wired in a non code compliant manner, exposed conductors on ceiling 7. Door frame missing southeast bedroom, cracked and damaged plaster 8. Holes cut into wall near switch, tenant removed drywall cover, new wiring dated 7/10/24 with no permits in the southeast bedroom. Wire tested live 9. No smoke detector southeast bedroom 10. Bathroom sink is clogged, not draining 11. Bathroom outlet tests w/ open neutral 12. Holes in bathroom door 13. Missing smoke detector in hallway 14. Ceiling missing from utility closet 15. Water heater installed 2016 with no permit. Ran water in kitchen and no hot water 16. Live exposed wiring that has been cut in utility closet. Isolated power by turning off the breaker for the furnace. The furnace has been removed 17. Missing light switch, open into junction box, outside utility closet 18. Hallway outside southeast bedroom, apparent electrical done without permits, wiring is cut and live conductors are not capped off and left loose inside the wall (not the junction box) 19. Kitchen window is broken 20. Rear door off kitchen door handle broken/inoperable and missing parts, door is cracked and damaged 21. Lightswitch in kitchen work without permits, wiring dated 07/2024, wire tests live 22. Drywall in kitchen ceiling replaced, surface not painted 23. Rear porch work without permits, porch extended to block wall on property line. Addition is rotted and collapsing 24. Wiring installed from breaker panel to west wall where a mini split HVAC system has been installed with no permits |