Case Details

Status:

Active

Type:

RFIR - TFD Callout for a structure fire at a single family residence
Address:

Entered Date:

03/25/2026

Applicant:

N/A

Description:

Completed Inspections

Case Status: Active
Case Number: CE-VIO0326-01376
Case Description: RFIR - TFD Callout for a structure fire at a single family residence
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/25/2026 COT - ENFC - Code Enforcement - Initial In Violation Arrived on scene at 137 AM and found TFD still on scene. According to TFD, origin of fire was in a storage room at the back of the carport, ceiling was pulled in dwelling to check for fire but fire did not spread to the main structure. Inspection reveals all structural members, including posts and roof structural members of the carport are heavily fire damaged. Roof decking of carport is heavily fire damaged and missing in parts near what appears to be the former storage room. There is exposed bare and burned copper electric wire from a run from electric panel to the carport storage room. This run came out of the electrical panel in a conduit and then had sheathed cable stapled to the roof of the structure. Carport door into home is breached and damage to door frame. There are electrical wires inside of the home abutting the carport wall that have visible signs of melting/fire damage. The interior of the home has ceiling removed and has smoke damage to the interior. Roof structural members over the dwelling near front window abutting the carport area, and at the rear door abutting the carport have visible signs of fire damage. Electric is off at meter upon arrival. SW Gas responded and gas is disconnected at meter. The structure is deemed as unsafe to occupy and has been posted with a red tag. Structure is to be repaired or demolished by a licensed contractor with an Issued permit. -VM

Scheduled Inspections

SCase Number - CE-VIO0326-01376
Case Status: Active
Case Description:
Scheduled Date Description Inspector Status
05/29/2026 COT - ENFC - Code Enforcement - Follow Up Scheduled

Documents

File Name Document Type  
CE-VIO0326-01376 EAOV SCAN.PDF DOCUMENTS VIEW
IMAGES 2026-03-25 CE-VIO0326-01376.PDF DOCUMENTS VIEW
IMG_0199.JPG DOCUMENTS VIEW
IMG_0200.JPG DOCUMENTS VIEW
IMG_0201.JPG DOCUMENTS VIEW
IMG_0202.JPG DOCUMENTS VIEW
IMG_0203.JPG DOCUMENTS VIEW
IMG_0204.JPG DOCUMENTS VIEW
IMG_0205.JPG DOCUMENTS VIEW
IMG_0206.JPG DOCUMENTS VIEW
IMG_0207.JPG DOCUMENTS VIEW
IMG_0208.JPG DOCUMENTS VIEW
IMG_0209.JPG DOCUMENTS VIEW
IMG_0210.JPG DOCUMENTS VIEW
IMG_0211.JPG DOCUMENTS VIEW
IMG_0212.JPG DOCUMENTS VIEW
IMG_0213.JPG DOCUMENTS VIEW
IMG_0214.JPG DOCUMENTS VIEW
IMG_0215.JPG DOCUMENTS VIEW
IMG_0216.JPG DOCUMENTS VIEW
IMG_0217.JPG DOCUMENTS VIEW
IMG_0218.JPG DOCUMENTS VIEW
IMG_0219.JPG DOCUMENTS VIEW
IMG_0220.JPG DOCUMENTS VIEW
IMG_0221.JPG DOCUMENTS VIEW
IMG_0222.JPG DOCUMENTS VIEW
IMG_0223.JPG DOCUMENTS VIEW
IMG_0224.JPG DOCUMENTS VIEW
IMG_0225.JPG DOCUMENTS VIEW
IMG_0226.JPG DOCUMENTS VIEW
IMG_0227.JPG DOCUMENTS VIEW
IMG_0228.JPG DOCUMENTS VIEW
IMG_0229.JPG DOCUMENTS VIEW
IMG_0230.JPG DOCUMENTS VIEW
IMG_0231.JPG DOCUMENTS VIEW