Case Details

Status:

Active

Type:

CFIR - Request for Building Safety due to a structure fire

Entered Date:

03/20/2026

Applicant:

N/A

Description:

Completed Inspections

Case Status: Active
Case Number: CE-VIO0326-01327
Case Description: CFIR - Request for Building Safety due to a structure fire
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/20/2026 COT - ENFC - Code Enforcement - Initial In Violation Arrived on site at 305 PM and spoke with Captain from TFD who states they were called out due to fire sprinkler alarm. Upon arrival staff at the office said there was no problems, TFD investigated and found the origin of the alarm as Unit 914. Upon arrival at the unit, TFD found water pouring out of the front door and smoke coming out of a window. Upon entry, TFD found the fire sprinkler over the stove activated due to a small fire on the stove, and the right back burner was on, possibly due to food left on the stove. Per TFD, fire did not pass beyond the drywall and there was 2-3 inches of standing water in the unit. Upon inspection, I found water is still draining out of the ceiling space. Paint on wall is bubbling on the wall in the kitchen above the light switch. There is fire damage to appliances, paint, and cabinets. Ceiling above stove at location of fire sprinkler is removed. Romex lines in this space have water on them but no visible cuts to sheathing. Drywall in the area of where the kitchen light fixture was is dry. Water damage to the wall behind the stove. GFCI in this area is wet and likely needs to be replaced as it has come in contact with water. The electrical line to the light switch has likely also come in contact with water and should be replaced. Checked breaker panel and found no water in the panel, and found no breakers tripped. TEP was called out to scene and cut power at 3:50 PM. Property management on scene agreed to secure the unit. A licensed contractor is required for repairs and repairs shall be completed with an Issued permit. Unit is condemned and has been red tagged as unsafe to occupy. Upon return at 8:50 PM the unit has been secured and front door is locked. -VM

Scheduled Inspections

SCase Number - CE-VIO0326-01327
Case Status: Active
Case Description:
Scheduled Date Description Inspector Status
06/03/2026 COT - ENFC - Code Enforcement - Follow Up Scheduled

Documents

File Name Document Type  
CE-VIO0326-01327 01 EAOV SCAN.PDF DOCUMENTS VIEW
CE-VIO0326-01327 02 NOV SCAN.PDF DOCUMENTS VIEW
IMAGES 2026-03-20 CE-VIO0326-01327.PDF DOCUMENTS VIEW
IMG_0019.JPG DOCUMENTS VIEW
IMG_0020.JPG DOCUMENTS VIEW
IMG_0021.JPG DOCUMENTS VIEW
IMG_0022.JPG DOCUMENTS VIEW
IMG_0023.JPG DOCUMENTS VIEW
IMG_0024.JPG DOCUMENTS VIEW
IMG_0025.JPG DOCUMENTS VIEW
IMG_0026.JPG DOCUMENTS VIEW
IMG_0027.JPG DOCUMENTS VIEW
IMG_0028.JPG DOCUMENTS VIEW
IMG_0029.JPG DOCUMENTS VIEW
IMG_0030.JPG DOCUMENTS VIEW
IMG_0031.JPG DOCUMENTS VIEW
IMG_0032.JPG DOCUMENTS VIEW
IMG_0033.JPG DOCUMENTS VIEW
IMG_0034.JPG DOCUMENTS VIEW
IMG_0035.JPG DOCUMENTS VIEW
IMG_0036.JPG DOCUMENTS VIEW
IMG_0037.JPG DOCUMENTS VIEW
IMG_0038.JPG DOCUMENTS VIEW
IMG_0039.JPG DOCUMENTS VIEW
IMG_0040.JPG DOCUMENTS VIEW
IMG_0041.JPG DOCUMENTS VIEW