Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Search

Parcel Attributes

Parcel132150210
JurisdictionTucson, Pima County
Water Course

Wash

City of Tucson ZoningI-1
Tucson WardWard 5
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Address: 801 E 47TH ST
Date - 11/06/2026 12:25 p.m.
Total Number Of Annexations & Original City Zoning (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-56-29 Southside 1650 2687

Special Development Requests & Requirements

Address: 801 E 47TH ST
Date - 11/06/2026 12:25 p.m.
Total Number Of Special Development Permits - (2)
Activity Number Status Apply Date Expired Date Unit Type Description
T18SA00450 APPROVED 10/03/2018 N/A Zoning Adminstration Letter
T21SA00161 APPROVED 04/30/2021 N/A Zoning Adminstration Letter MMJ

Permits

Address: 801 E 47TH ST
Date - 11/06/2026 12:25 p.m.
Total Number Of Permits - (12)
Permit Status Apply Date Expired Date Unit Type Description
TC-COM-1222-00361 Expired 12/23/2022 06/21/2023 Commercial Building Project is an interior expansion of an existing medical marijuana growing facility. Dispensary shall be off site. This tenant interior expansion will involve demising off a portion of an existing unused warehouse space. The remaining unused portion will be left unimproved and will be assessable through a keyed lock door that will have a sign stating that “THIS IS NOT AN EXIT.” The following portion of the narrative is to address particular items that required further clarifications during the initial tenant improvement: 1. Plant Irrigations System: The crop irrigation system is a self-circulating gray water system that is designed and installed an irrigation company. The gray water is recirculated from the plants, stored in a separate holding tank, filtered and then fed back into the irrigation system. This system in replenished using city water that connects to a reverse osmosis system that fills a primary holding tank. The city water line is protected by a back flow device and is not connected directly to the irrigation piping. 2. City of Tucson Use Permit T185SA00450, condition requires that an “odor mitigation plan be submitted. The mechanical design for the working area, which are those areas which are separate for the growing rooms, are designed to provide outside are into the space. This will be exhausted from the building through roof mounted exhaust vents. These vents will be equipped with charcoal filters to remove building odors. 3. The existing equipment room contains an 8’-0” diameter water storage tank that contains 3,000 gallons of water. Existing floor slab is 6” concrete and the building was designed as an industrial warehouse. The 6” thickness of the slab and its placement on natural grade is sufficient to handle the new load.
TF-FCP-0924-00764 Complete 09/09/2024 04/21/2025 Fire Construction Permit NEW dedicated function system and Starlink Radio install
T22CM05285 Expired 07/12/2022 N/A Commercial Building TI: Medical marijuana growing facility
T19BU00210 EXPIRED 04/25/2019 11/03/2019 DEMO FULL DEMO
T19CM00710 C OF O 01/31/2019 03/24/2020 COMBO MEDICAL MARIJUANA DISPENSARY OFF-SITE CULTIVATION LOCATION
T19FC00386 FINAL 05/21/2019 03/23/2020 FIRECONS Install new wet pipe fire sprinkler system
T19FC00414 FINAL 05/31/2019 01/19/2020 FIRECONS INSTAL 150'-0" OF NEW 4" C-900 UNDERGROUND FIRE LINE.
T19FC00623 FINAL 08/12/2019 03/24/2020 FIRECONS TI
T19RW03226 FINAL 06/07/2019 07/11/2019 ROW NEW FIRE SERVICE
T19RW03749 FINAL 07/03/2019 10/06/2019 ROW STARTING ON THE NW COR OF 46TH ST/EVANS BL, OVERLASH SOUTHEAST 310', THEN SW TO OUT OF ROW
T21FO00100 WITHDRWN 02/25/2021 02/25/2022 FIREOPER TEAC FARMS AGRICULTURE STF ***DUPLICATE SEE PERMIT# T21FO00321 per Inspector Smith***
T21FO00321 FINAL 05/26/2021 12/04/2021 FIREOPER TME WILLIAMS - STATE LICENSE B