Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Search

Parcel Attributes

Parcel10711254A
JurisdictionTucson, Pima County
City of Tucson ZoningR-2
Tucson WardWard 3
Tucson Registered NeighborhoodKeeling
Pima County Data Assessor, Recorder, Treasurer, ...
Parcel Map Map
Parcel Attributes Issue?

Annexations & Original City Zoning (OCZ)

Address: 315 E BLACKLIDGE DR
Date - 08/19/2026 1:23 p.m.
Total Number Of Annexations & Original City Zoning (1)
Plan Description Annexation Ordinance Effective Date OCZ Ordinance
C9-59-19 North To Roger Rd. And East To Kolb Rd. 1895 1957

Special Development Requests & Requirements

Address: 315 E BLACKLIDGE DR
Date - 08/19/2026 1:23 p.m.
Total Number Of Special Development Permits - (1)
Activity Number Status Apply Date Expired Date Unit Type Description
H000005888 CLOSED 06/11/2014 N/A Historical Information RECORD TO SHOW BILLBOARD AZ488/CLEAR CHANNEL #301 REMOVED DUE TO STORM DAMAGE

Permits

Address: 315 E BLACKLIDGE DR
Date - 08/19/2026 1:23 p.m.
Total Number Of Permits - (11)
Permit Status Apply Date Expired Date Unit Type Description
TC-COM-1123-02702 Issued 11/21/2023 06/11/2024 BLDG 0 UNIT 4 Commercial Building -We will dig up approx. 15' from the meter in the backyard of unit #1 to the back (exterior) wall of the building. We will install new 1" P.P pipe with tracer wire and steel risers. We will install new 1/4 turn isolation valve at the building. We will then run steel pipe up to the roof. We will run new 1" steel pipe approx. 70". We will install tee to supply the furnace and then run 3/4" pipe to the furnace and down the exterior wall for the water heater. We will install new 1/4 turn gas valve and gas flex supply lines for the water and the furnace. Also install sediment taps on the water heater and furnace. We will install bonding wire between the gas pipe and the cold-water lin. We will install carbon monoxide detector in the home. WE will place gas line on 15psi pressure test and schedule inspection. After inspection we will back fill trench. Re-pipe is for Unit #4.
TC-RES-1123-09608 Void 11/20/2023 N/A BLDG 0 UNIT 4 Residential Building - One or Two Family *VOID: YL-Unable to process, wrong permit type. Submit a new application under Commercial Trade Permit. Property shows multiple units attached and a building that has more than two addresses/units is considered commercial. Please submit your drawing with your new permit submittal. This permit will be voided as it is not the correct permit type * -We will dig up approx. 15' from the meter in the backyard of unit #1 to the back (exterior) wall of the building. We will install new 1" P.P pipe with tracer wire and steel risers. We will install new 1/4 turn isolation valve at the building. We will then run steel pipe up to the roof. We will run new 1" steel pipe approx. 70". We will install tee to supply the furnace and then run 3/4" pipe to the furnace and down the exterior wall for the water heater. We will install new 1/4 turn gas valve and gas flex supply lines for the water and the furnace. Also install sediment taps on the water heater and furnace. We will install bonding wire between the gas pipe and the cold-water lin. We will install carbon monoxide detector in the home. WE will place gas line on 15psi pressure test and schedule inspection. After inspection we will back fill trench. Re-pipe is for Unit #4.
TR-UTL-0825-01431 Needs Resubmittal 08/26/2025 N/A BLDG 0 UNIT 1 Right-of-Way (ROW) - Utility P.174818.E.01 & P.174828.E.01- Transfer CenturyLink services from old utility poles to new foreign poles already in place.
T21CM00995 Expired 02/01/2021 07/31/2021 4 Residential Building - One or Two Family Gas pressure test
T02EL01154 EXPIRED 06/04/2002 12/02/2002 #04 ELECT ELECTRIC:RECONNECT
T03EL00048 FINAL 01/09/2003 07/13/2003 #01 ELECT RECONNECT:ELECTRIC:APT
T05EL00940 FINAL 05/09/2005 05/24/2006 #05 ELECT ELECTRIC RECONNECT:LAUNDRY ROOM
T12CM04631 FINAL 07/30/2012 01/28/2013 #03 COMBO RECONNECT:ELECTRIC:APT
T16CM09248 FINAL 12/12/2016 06/12/2017 COMBO REPAIR AND REPL SPLICE LUGS
T19CM03441 FINAL 05/14/2019 11/16/2019 #04 COMBO GAS LINE REPAIR
T21RW00634 FINAL 02/09/2021 03/12/2021 ROW (2) 5X5 bell holes in blktp front- to repair/replace gas line ISSAP NPL