Permits

Date - 10/27/2026 9:02 p.m.
Number Of Permits - (1)
Permit Status Apply Date Expired Date Unit Type Description
TC-RES-0825-03916 Inspections 08/07/2025 06/17/2027 Residential Building - One or Two Family REV1: installation of 125 AMP Electrical Service in the subject location, instead of the 200 AMP requested in the original set of Approved Construction Plans. Additionally, instead of an overhead electrical line drop, there is an existing underground feeder line which will be utilized (TEP is unable to provide an overhead line drop to the subject property) THE SCOPE OF WORK INVOLVES THE REMEDIATION OF FIRE DAMAGE AND RENOVATION OF AN EXISTING TOWNHOME. MAJOR RENOVATIONS INCLUDE: 1. FINISHES: REPLACE ALL INTERIOR FINISHES, REPLACE DRYWALL AT CEILINGS AND INTERIOR WALLS, FUR OUT THE INTERIOR SIDE OF EXTERIOR NON-FRAMED WALLS (I.E. BLOCK WALLS) AND INSTALL NEW DRYWALL, REPLACE DOORS AND WINDOWS, AND REPLACE INSULATION. 2. STRUCTURAL: ADDRESS FINDINGS OF THE SOUTHWEST ENGINEERING, STRUCTURAL ENGINEERS, LLC STRUCTURAL INSPECTION REPORT SWE JOB# 2533 (SUBMITTED ALONG WITH THESE PLANS), INCLUDING DEMOLITION AND REBUILT OF FIRE DAMAGED BACK PORCH AND STORAGE, REPLACEMENT OF SIX SEVERELY FIRE DAMAGED ROOF RAFTERS AND TWO OTHER ROOF RAFTERS FOUND TO BE CRACKED, REINFORCEMENT OF TEN ROOF RAFTERS WITH MINOR FIRE DAMAGE, AND DEMOLITION AND REPLACEMENT OF APPROX. 546 SF OF FIRE DAMAGED ROOF SHEATHING OVER SAID RAFTERS. ADDITIONALLY, EXTEND FIRE WALLS BETWEEN SUBJECT AND ADJACENT TOWNHOMES TO A HEIGHT NOT LESS THAN 30" ABOVE ROOF BY INSTALLING FIREWALL PARAPETS, INSPECT AND REPAIR/REPLACE ANY OTHER DAMAGED ROOF RAFTERS AND OTHER ROOF FRAMING MEMBERS (IF ANY ARE FOUND TO BE DAMAGED), INSPECT AND REPLACE ANY DAMAGED ROOF DECKING, AND CREATE AN OPENING FROM THE KITCHEN TO THE LIVING ROOM. 3. ELECTRICAL: REPLACE EXISTING ELECTRICAL PANEL, ELECTRICAL DISTRIBUTION AND FIXTURES. 4. PLUMBING: INSPECT SEWER LINE FROM WITHIN THE HOME TO THE HCS AND REPAIR/REPLACE AS NECESSARY IF ANY PORTIONS OF IT ARE FOUND DAMAGED, REPLACE EXISTING WATER DISTRIBUTION, REPLACE EXISTING PLUMBING FIXTURES, AND REPLACE EXISTING WATER HEATER. EXISTING WATER AND GAS METERS REMAIN. 5. MECHANICAL: REPLACE EXISTING HVAC WITH NEW HVAC SYSTEM, REPLACE EXISTING MECHANICAL DISTRIBUTION, AND REPLACE EXISTING EXHAUST FANS. 6. GENERAL: INSTALL A NEW FLAT ROOF ON HOME AND BACK PORCH, INSPECT ROOF OF FRONT PORCH AND GARAGE AND REPLACE AS MIGHT BE NECESSARY FROM THE RESULTS OF THE INSPECTION, REPAIR REAR FENCE ON WEST SIDE OF GARAGE AND REPAINT HOME EXTERIOR AS NECESSARY.

Documents

File Name Document Type  
COFT - PDSD - PERMIT CARD (SSRS).PDF DOCUMENTS VIEW
CONS-CONS-5846 E GRANT RD 20260130_V1_REV1_V1.PDF DOCUMENTS VIEW
REVISION 1 NARRATIVE - 5846 E GRANT RD_V1.PDF DOCUMENTS VIEW
COFT - PDSD - PERMIT CARD.PDF DOCUMENTS VIEW
CONS-CONS-5846 E GRANT RD 20250807_V1.PDF DOCUMENTS VIEW