Permits
Date - 08/17/2026 6:34 a.m.
Number Of Permits - (1)
| Permit | Status | Apply Date | Expired Date | Unit | Type | Description |
|---|---|---|---|---|---|---|
| TC-RES-0626-02865 | Inspections | 06/01/2026 | 06/11/2027 | Residential Building - One or Two Family | TEP Required Corrections (1) Riser is 1.25" Rigid. Minimum riser size needs to be 2" rigid/IMC. (See SR-305 note 5) (2) Rigid bracing attached to riser does not meet minimum requirements of SR-305, note 1 and Detail A. (3) Centerline of meter is too high, at 80". Must be a maximum of 6'3" to centerline. (See SR-305, note 12 and SR-405, note 4) (4) Address label must be screwed or riveted onto meter base. (5) Meter enclosure must be sealed with an access plate, not a basic KO seal (See SR-405 note 7) |