Review Status: Stopped
Review Details: COMMERCIAL TI
Permit Number - T99CM05582
Review Name: COMMERCIAL TI
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/22/2000 | CRAIG GROSS | ZONING | REVIEW | Passed | |
| 09/29/2000 | RANDY SCHULER | ELECTRICAL-COMMERCIAL | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES ELECTRICAL REVIEW COMMENTS DATE: September 28, 2000 ACTIVITY NUMBER: T99CM05582 PROJECT NAME: Park Lighting PROJECT ADDRESS: 3250 S. Jessica Av. PROJECT REVIEWER: Randy Schuler, P.E. E1 and E6 1) Provide a # 6 equipment ground from both poles C1 and C2 all the way back to the service. In addition the taps from the #6 equipment ground to all the other poles must be a minimum of a #8. See 99NEC 250-122 E1 1) Pole B1 lacks the number of conductors required to serve 7 lights. 2) Please provide the alpha/numeric designation along with the number of fixtures served adjacent to each pole. This will simplify the plan review, inspection and installation of the project. E6 1) Remove the ground from the service lateral. If left in it will provide a parallel path for the normal current to flow. In addition the utility will not land it in the transformer. 2) Both the lighting and power loads in the load calculation appear to be incorrect. Please carefully review all the loads and revise as necessary. E7 1) Revise the panel schedule to reflect the fixture VA as opposed to lamp wattage. See 99NEC 220-4(b) GENERAL COMMENT 1) Please return the plans I have already reviewed along with your next submission. Please note I cannot begin my second review without the original set for comparison purposes. |
| 10/16/2000 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | 1.PROVIDE STRUCTURAL CALCULATIONS AND DRAWINGS FOR LIGHT POLES, BY AN ARIZONA REGISTERED STRUCTURAL ENGINEER. 2. PROVIDE STRUCTURAL CALCULATIONS AND DRAWINGS FOR MOUNTING HARDWARE AND CROSSARMS , BY AN ARIZONA REGISTERED STRUCTURAL ENGINEER. 3. PROVIDE SITE PLAN DIMENSIONALLY LOCATING LIGHT POLES FROM ADJACENT PROPERTY LINES , BY AN ARIZONA REGISTERED ARCHITECT OR ENGINEER. 4. PROVIDE CHECK OF PERMISSIBLE STRESSES IN PLAIN CONCRETE PER UBC SEC 1923.7. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/22/2001 | BALDERET | APPROVAL SHELF | Stop |
| 09/22/2000 | ANY | OUT TO CUSTOMER | Stopped |
| 09/22/2000 | ANY | REJECT SHELF | Stopped |