Plan Number: T22PRE0217
Parcel: Unknown

Address:
302 E CORONA RD

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0217
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2022 JPEELDA1 COT NON-DSD FIRE Completed DP shall show existing fire hydrant on the corner of Geronimo and Corona. Hydrant is within required distance. As long as the houses remain under roof 3,599 sq feet fire sprinklers will not be required.

Questions:

Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Fire Plans Examiner
Tucson Fire Department
10/10/2022 DSTIFFE1 COT NON-DSD TRAFFIC Reqs Change T22PRE0217
Comments:
1. Concrete sidewalk in the ROW along Geronimo Ave and Corona Rd, must be 5 Ft wide and according to P.A.G. standard 200.
2. Concrete wedge curb to be constructed per P.A.G. standard 209.
3. For additional information contact an inspector for an onsite precon. 520-791-5100

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
10/12/2022 GPENNIN1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review
FROM: Georgia Pennington, Planner

PROJECT: Thursday Presubmittal meeting 10/13/2022
Address: 302 & 322 E Corona Rd
Parcel(s): 116-19-156B
Current Zoning: R-2
Existing Use: Undeveloped
Proposed Use: Single-Family Residential (through a minor subdivision)
.
TRANSMITTAL DATE: 10/12/22

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-07 - Minor Subdivision. The Minor Subdivision application is a separate submittal from the building permits, and the building permits cannot be approved until the Minor Subdivision is approved.
2. The existing zone is R-2. Single-Family Residential is permitted within the R-2 zone, subject to Use-Specific Standards 4.9.7.B.6, .9, .20 & 6 and .10.
3. Minimum lot size: 5,000 SF/ lot
4. Maximum Height: 25 feet
5. Setbacks
a. 6' or 2/3 the height of the wall facing the Rear and Side yard lot lines
b. 20' Front Street
6. Motor Vehicle Space requirements: 2 spaces per dwelling unit plus visitor parking required at a ratio of 0.25 space per unit.
7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov.
10/12/2022 JCARLTO1 LANDSCAPE REVIEW Reqs Change CDRC TRANSMITTAL

ACTIVITY NO. T22PRE0217

ADDRESS/PARCEL: 302 E CORONA RD/138-17-032A

ZONING: R-2



COMMENTS:



A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. Please note that Mesquite hybrids will be considered native trees and should be included in NPP inventory.

If you have any questions about this transmittal, please contact Matthew Carlton at Matthew.Carlton@tucsonaz.gov

If you have any questions about this transmittal, please contact Matthew Carlton at Matthew.Carlton@tucsonaz.gov
10/12/2022 JGARCIA9 ENGINEERING REVIEW Completed 1. The south end of the parcel is in an Estimated Flood Hazard Zone. Please acquire a Floodplain Use Permit prior to submitting a development package. https://www.tucsonaz.gov/pdsd/floodplain-information
2. Minor subdivision is not allowed unless you can show the flood plain does not impinge on the property with a drainage study.
3. Part of the parcel is within the Airport Hazard District, be sure to comply with restrictions in the Tucson UDC sec 5.6.11. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-3886
4. Maximize water harvesting depress landscaping basin 6-9 Inches.

Joshua Garcia
joshua.garcia@tucsonaz.gov
520-837-5339
10/13/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T22PRE0217 - 302 E CORONA RD
Minor Subdivision: Ocotillo Oeste

Completed

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov