Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T22PRE0217
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/20/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | DP shall show existing fire hydrant on the corner of Geronimo and Corona. Hydrant is within required distance. As long as the houses remain under roof 3,599 sq feet fire sprinklers will not be required. Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner Tucson Fire Department |
| 10/10/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Reqs Change | T22PRE0217 Comments: 1. Concrete sidewalk in the ROW along Geronimo Ave and Corona Rd, must be 5 Ft wide and according to P.A.G. standard 200. 2. Concrete wedge curb to be constructed per P.A.G. standard 209. 3. For additional information contact an inspector for an onsite precon. 520-791-5100 David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 10/12/2022 | GPENNIN1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Georgia Pennington, Planner PROJECT: Thursday Presubmittal meeting 10/13/2022 Address: 302 & 322 E Corona Rd Parcel(s): 116-19-156B Current Zoning: R-2 Existing Use: Undeveloped Proposed Use: Single-Family Residential (through a minor subdivision) . TRANSMITTAL DATE: 10/12/22 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-07 - Minor Subdivision. The Minor Subdivision application is a separate submittal from the building permits, and the building permits cannot be approved until the Minor Subdivision is approved. 2. The existing zone is R-2. Single-Family Residential is permitted within the R-2 zone, subject to Use-Specific Standards 4.9.7.B.6, .9, .20 & 6 and .10. 3. Minimum lot size: 5,000 SF/ lot 4. Maximum Height: 25 feet 5. Setbacks a. 6' or 2/3 the height of the wall facing the Rear and Side yard lot lines b. 20' Front Street 6. Motor Vehicle Space requirements: 2 spaces per dwelling unit plus visitor parking required at a ratio of 0.25 space per unit. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Georgia.Pennington@tucsonaz.gov. |
| 10/12/2022 | JCARLTO1 | LANDSCAPE | REVIEW | Reqs Change | CDRC TRANSMITTAL ACTIVITY NO. T22PRE0217 ADDRESS/PARCEL: 302 E CORONA RD/138-17-032A ZONING: R-2 COMMENTS: A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. Please note that Mesquite hybrids will be considered native trees and should be included in NPP inventory. If you have any questions about this transmittal, please contact Matthew Carlton at Matthew.Carlton@tucsonaz.gov If you have any questions about this transmittal, please contact Matthew Carlton at Matthew.Carlton@tucsonaz.gov |
| 10/12/2022 | JGARCIA9 | ENGINEERING | REVIEW | Completed | 1. The south end of the parcel is in an Estimated Flood Hazard Zone. Please acquire a Floodplain Use Permit prior to submitting a development package. https://www.tucsonaz.gov/pdsd/floodplain-information 2. Minor subdivision is not allowed unless you can show the flood plain does not impinge on the property with a drainage study. 3. Part of the parcel is within the Airport Hazard District, be sure to comply with restrictions in the Tucson UDC sec 5.6.11. https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-3886 4. Maximize water harvesting depress landscaping basin 6-9 Inches. Joshua Garcia joshua.garcia@tucsonaz.gov 520-837-5339 |
| 10/13/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 200 - 230 pm - T22PRE0217 - 302 E CORONA RD Minor Subdivision: Ocotillo Oeste Completed 1. Tucson Water's New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |