Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T22PRE0209
Parcel: Unknown

Address:
201 S WILMOT RD

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0209
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2022 JPEELDA1 COT NON-DSD FIRE Completed Yes, you will need to modify the fire alarm and fire sprinkler system. If modifications are made to the kitchen fire suppression line a permit shall be obtained from TFD as well.
The bulk CO2 system shall have an operational and construction permit obtained from TFD and be interconnected with the building fire alarm system
Owner shall obtain an operational permit for places of assembly from TFD

Fire sprinkler, fire alarm, CO2 and Kitchen systems permits shall all be noted on drawings a a sperate permit from TFD

Questions:

Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Fire Plans Examiner
Tucson Fire Department
09/26/2022 DSTIFFE1 COT NON-DSD TRAFFIC Completed No Comment
09/28/2022 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T22PRE0209
Address: 203 S Wilmot Rd.
Parcel(s): 134234120
Zoning: C-1
Existing Use: Food Service/Vacant
Proposed Use: Food Service

TRANSMITTAL DATE: 9/28/22

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Any site changes or building additions will require a Development Package.
3. Food Service is an allowed use in the C-1 zone and is subject to Use Specific Standards 4.9.4.M.1 & 5 and 4.9.13.O
4. There are no applicable overlays.
5. There are no design standards.
6. A Development Package (DP) will be required to be issued prior to any building permits, but the building permits may be in review at the same time as the DP.
7. Vehicular parking is required at 1 space per 100 sq. ft. GFA and outdoor seating areas. With a building size of 4,418 SF, 44 parking spaces are required.
8. Short-term bike parking is required at 1 space per 2,000 sq. ft. GFA. Minimum requirement is 2 spaces.
9. Long-term bike parking is required at 1 space per 12,000 sq. ft. GFA. Minimum requirement is 2 spaces.
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
09/28/2022 SHASEMA1 ENGINEERING REVIEW Completed Project: T22PRE0209
Address: 201 S WILMOT RD

Engineering has no comments at this time

Scott Haseman
Scott.haseman@tucsonaz.gov
09/29/2022
09/29/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Hawaiian Bros
ACTIVITY NO. T22PRE0209
ADDRESS/PARCEL: 203 S Wilmot
ZONING: C-1

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or expansions of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

• Provide landscape adjacent to the expansion

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening – Maximize water harvesting
If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
09/29/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T22PRE0209 - 203 S WILMOT RD - Site Hawaiian Bros

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience:

2. The existing restaurant at this location is served by a 4" fire service connected to the existing 4" public water main on the east side of Wilmot Road. Should a new, larger fire service be needed for the new restaurant, it will need to connect to connect to the exiting 12" public water main on the west side of Wilmot Road.

3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov