Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: T22PRE0207
Parcel: Unknown

Address:
5745 S 6TH AV

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0207
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/20/2022 JPEELDA1 COT NON-DSD FIRE Reqs Change All houses shall be within 600' of a fire hydrant and or fire sprinklers shall be installed and or additional hydrants. There is 1 hydrant located about 350' from the back of the property line. If you installed an new fire hydrant at the end by lots 8 & 16 you might meet the 2 hydrants within 600' and meet the fire flow so that fire sprinklers do not need to be installed. If adding hydrants for fire flow please ensure that the fire hydrants new and existing are shown on the DP.

Questions:
Jennifer Peel-Davis
Tucson Fire Department
Fire Plans Examiner
Fire Inspector I, II and Fire Alarm Plans Examiner
Jennifer.Peel-Davis@Tucsonaz.gov
Desk: 520-837-7033
09/26/2022 DSTIFFE1 COT NON-DSD TRAFFIC Reqs Change T22PRE0207
Comments:
1. New concrete curb per P.A.G. standard 209 is required, along the entire property frontage of south 6th Ave.
2. New 6 Ft wide concrete sidewalk per P.A.G. standard 200 is required, along the entire property frontage of south 6th Ave.
3. New curb returns are to have a 25 Ft. radius.
4. New concrete curb access ramps to be constructed at each curb return, per P.A.G. standard 207.
5. Construct new curb- 5 Ft from the center of the WS6 (white) bike lane stripe- measurement to gutter line of new curb.
6. 3' minimum buffer between curb and sidewalk.
7. Sidewalk from property must connect to sidewalk in the ROW. An ADA landing is required at this sidewalk connection. Landings shall be 60" X 60" and not to exceed a 2% cross slope in all directions.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
09/28/2022 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T22PRE0207 (Lomeli Subdivision)

TRANSMITTAL DATE: 9/27/2022



A Tentative plat will be required for this site. Information on the development package and tentative plat can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf

Development must comply with the Administrative Manual Section 2-06.5.0- FLEXIBLE LOT DEVELOPMENT (FLD)

The Dimensional standard for Alternative A in the R-2 zone are 62% site coverage max, building height 25ft. There is no minimum lot size within an FLD.

Interior lot setbacks “The perimeter yard requirements of Section 6.3.4, Dimensional Standards and Exceptions Tables, may be reduced for setbacks along interior lot lines to the extent permitted by the City’s adopted Building Codes”

Perimeter yard along FLD project site boundaries. The setback to the north is the greater of 6ft or 2/3 height of the structure. The setback along 6th would be 21ft measured from the back of future curb.




For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov / (520) 837-4082
09/29/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Lomeli Subdivision
ACTIVITY NO. T22PRE0207
ADDRESS/PARCEL: 138-10-013A/B
ZONING: R-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

• A 10’ minimum street landscape border is required along all public streets

7.7. Native Plant Preservation
The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survive.
A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. Please note that Mesquite hybrids will be considered native trees and should be included in NPP inventory.

8.7.3. Flexible Lot Development – Depending on option chosen, additional landscape requirements shall apply.

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
09/29/2022 JGARCIA9 ENGINEERING REVIEW Completed 1. Maximize water harvesting 
2. Balanced basin detention and first flush retention regulations are required. Please refer to the updated retention/detention manual at: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With amendments listed at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
3. Demo permits required – Review with historic, 1 SFR Const 1933, 1 Const 1943. See https://www.tucsonaz.gov/files/pdsd/forms/2019_Historic_or_Older_Demo_Documentation_Form_and_Instructions.pdf
4. All easements such as the roadway must be recorded on the Final Plat.

Joshua Garcia
joshua.garcia@tucsonaz.gov
09/29/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed View in DOCUMENTS section of PRO, titled "Tucson Water, presubmittal meeting comments"