Plan Number: T22PRE0197
Parcel: Unknown

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T22PRE0197
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
09/13/2022 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
09/13/2022 BILLIE LEE COMMENTS COMMENTS Active
09/13/2022 ANY ELECTRICAL ENGINEERING REVIEW Active
09/13/2022 JPEELDA1 FIRE REVIEW Reqs Change F.D.C. shall face the street side of the building, IFC 2018, Chapter 9, Section 912, 912.2.1

IFC 2018, Appendix D, D103.4 Dead ends. Dead-end fire apparatus access roads in excess of 150’ shall be provided with turnaround provisions in accordance with Table D103.4

Fire hydrants shall be located within 400 ft of new structures. IFC 2018, Chapter 5, Section 507.5.1 and also in accordance with IFC Appendix D. Please show new and existing fire hydrant locations on the plans and or fire sprinklers shall be installed.

Buildings exceeding 30’ shall be provided with aerial access meeting IFC 2018, Appendix D, Section D105. D105.3 Proximity to building. One or more of the required access routes meeting this condition shall be located not less than 15’ and not greater than 30’ from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which aerial apparatus access road positioned shall be approved by the fire code official.

Questions:
Jennifer Peel-Davis
Tucson Fire Department
Fire Plans Examiner
Fire Inspector I, II and Fire Alarm Plans Examiner
Jennifer.Peel-Davis@Tucsonaz.gov
Desk: 520-837-7033
09/14/2022 NMARTEL1 ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Nick Martell
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T22PRE0197
Address: 8750 E Golf Links Rd
Parcel(s): 13613020A
Existing Zoning: C-1
Proposed Zoning: C-2
Existing Use: Vacant
Proposed Use: Storage-Personal Storage

TRANSMITTAL DATE: September 14, 2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Proposed use and use-specific standards: 4.9.10.C.3 & .6
3. Development standards: 40' Building Height Max from design grade
4. Perimeter yard setbacks: Adjacent to Commercial Zones (all): 0' setback
5. Applicable street setbacks: Golf Links is a Major Street and Route and subject to MS&R Setbacks
6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445
7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698
8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov
9. Additional comments:
a. The parcel is partially in an Estimated Flood Hazard Zone. Please contact engineering regarding any special standards that may apply.
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at nicholas.martell@tucsonaz.gov.