Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T22PRE0190
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 09/06/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | |
| 09/06/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | Questions: Jennifer Peel-Davis Tucson Fire Department Fire Plans Examiner Fire Inspector I, II and Fire Alarm Plans Examiner Jennifer.Peel-Davis@Tucsonaz.gov Desk: 520-837-7033 |
| 09/07/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Provide a Development Package that shows all the existing and proposed site conditions compliant with the rezoning conditions. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 09/07/2022 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: U-Haul ACTIVITY NO. T22PRE0 ADDRESS/PARCEL: 8740 E Broadway Bl. ZONING: C-1, proposed C-2 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. • Replace any missing trees in parking islands • A 10’ minimum street landscape border is required along all public streets, add any missing plants • Minimum 10’ Interior landscape borders are required adjacent to any single-multi family use, regardless of zoning Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 09/08/2022 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers, Planner PROJECT: Thursday Pre-submittal meeting - T22PRE0190 Address: 8740 E BROADWAY BL Parcel(s): 133311080 Zoning: C-2 (C9-21-18) Existing Use: Warehouse/Vacant Proposed Use: Personal Storage TRANSMITTAL DATE: 09/08/2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Personal Storage is an allowed use and is subject to use specific standards 4.9.10.C and 4.9.13.O. a. All walls or doors visible from adjacent streets and residential properties shall be surfaced with a non-reflective material. b. The maximum permitted individual unit size is 200 square feet of floor area c. Razor or barbed wire shall not be used. d. The facility's exterior facade visible from adjoining residential properties or street frontage shall be earth tone in color and of masonry, stucco, or similar materials. 3. Site changes to a commercial development are required to be shown on a Development Package, for minor changes see: https://www.tucsonaz.gov/files/pdsd/forms/Minor_Changes_to_Commercial_Industrial_Sites_.pdf 4. Pedestrian connection must be provided from the building to the adjacent Right of Way. 5. For sites that encompass multiple parcels a Covenant Regarding Development and Use of Real Property must be provided: https://www.tucsonaz.gov/files/pdsd/Covenant_Regarding_Development_and_Use_of_Real_Property_UDC.pdf 6. Parking is required at 1 space per 4,000 sq. ft. GFA, if storage units do not have direct vehicular access, and a minimum of 2 spaces for any associated office. 7. For parking lots with 201 to 300 provided parking spaces 7 ADA spaces are required with 2 being Van Accessible spaces. 8. For personal storage developments without direct vehicular access that are less than 50,000 sq. ft. is Gross Floor Area 1 Type-A loading space is required. 9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932. |
| 09/08/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Reqs Change | 130 - 200 pm - T22PRE0190 - 8740 E BROADWAY SiteGradingSwppp: U-Haul Action Required 1. An existing 8" cement asbestos water main that was constructed under Tucson Water Plan No. 061-1971 lies just south of the main building. This plan also shows an 8" public sewer line, paralleling the water main for most of its length. And power lines paralleling the water main for a shorter distance. Although this plan shows these public utility lines in a public utility easement, I have been unable to find any record of any recorded public utility easement every having been granted over them. 2. If the Applicant cannot produce a recorded public utility easement over these public utility lines during the rezoning process, Tucson Water requests that a condition be added to the rezoning that requires the recordation of an adequate public utility easement over these public utility lines within 1 year of Mayor and Council's approval. 3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |