Plan Review Detail
Review Status: Active
Review Details: PREAPPLICATION MEETING
Plan Number - T22PRE0184
Review Name: PREAPPLICATION MEETING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/30/2022 | JOHN BEALL | M&C Public Hearing 4 Plan Amendment | Set M&C Public Hearing Date | Active | |
| 08/30/2022 | BILLIE LEE | COMMENTS | COMMENTS | Active | |
| 08/30/2022 | ANY | ELECTRICAL ENGINEERING | REVIEW | Active | |
| 08/30/2022 | JPEELDA1 | FIRE | REVIEW | Reqs Change | Buildings exceeding 30’ shall be provided with aerial access meeting IFC 2018, Appendix D, Section D105. D105.3 Proximity to building. One or more of the required access routes meeting this condition shall be located not less than 15’ and not greater than 30’ from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which aerial apparatus access road positioned shall be approved by the fire code official. Questions: Jennifer Peel-Davis Fire Plans Examiner Tucson Fire Department 520-837-7033 Jennifer.Peel-Davis@Tucsonaz.gov |
| 08/31/2022 | NMARTEL1 | ZONING | REVIEW | Completed | Rezoning Pre-Submittal Transmittal FROM: Nick Martell PDSD Zoning Review PROJECT: Rezoning Pre-submittal meeting T22PRE0184 Address: 980 W Irvington Rd Parcel(s): 120052770 Existing Zoning: C-1 Proposed Zoning: C-2 Existing Use: Vacant Proposed Use: Storage-Persona Storage TRANSMITTAL DATE: August 31, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Proposed use and use-specific standards: 4.9.10.C.3 & .6 3. Development standards: 40 ft building height, No lot coverage maximum 4. Perimeter yard setbacks: Adjacent to R-1 zone = 1 ½ H. Adjacent to C-2 zone = 0. 5. Applicable street setbacks: Frontage Road setbacks will need to be discussed with ADOT 6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445 7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698 8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov 9. Additional comments: a. No adverse comments. Please check with ADOT on any other standards for development adjacent to State roadways 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at nicholas.martell@tucsonaz.gov. |