Plan Review Detail
Review Status: Active
Review Details: PREAPPLICATION MEETING
Plan Number - T22PRE0175
Review Name: PREAPPLICATION MEETING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/16/2022 | JPEELDA1 | FIRE | REVIEW | Completed | Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 08/23/2022 | BILLIE LEE | COMMENTS | COMMENTS | Active | |
| 08/23/2022 | NMARTEL1 | ZONING | REVIEW | Completed | Rezoning Pre-Submittal Transmittal FROM: Nick Martell PDSD Zoning Review PROJECT: Rezoning Pre-submittal meeting T22PRE0175 Address: 821 S 7th av Parcel(s): 117081010 Existing Zoning: R-3 Proposed Zoning: C-3 Existing Use: Vacant Proposed Use: Parking/Storage TRANSMITTAL DATE: August 23, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Proposed use and use-specific standards: None 3. Development standards: 75' ft building height 4. Perimeter yard setbacks: Adjacent to Non-residential zones = 1 ½ H. Adjacent to C-3 zone = 0. 5. Applicable street setbacks: Street setbacks as established in 6.4.5.C of the UDC 6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445 7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698 8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov 9. Additional comments: A. While parking is an approved use in the C-3, an accessory storage use along with the primary parking use may not meet the definition of accessory in the unified development code. More information is needed regarding the use of the parcel to determine exactly how zoning would identify a primary use. A storage use will be subject to different standards, including wider PAAL widths (4.8.4 UDC). B. Please see 7.4.6.B for off-site parking requirements 10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at nicholas.martell@tucsonaz.gov. |
| 08/23/2022 | ANY | ELECTRICAL ENGINEERING | REVIEW | Active | |
| 08/23/2022 | JOHN BEALL | M&C Public Hearing 4 Plan Amendment | Set M&C Public Hearing Date | Active |