| 07/28/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | T22PRE0160 Comments: 1. ADOT Right of Way. Please contact ADOT for ROW improvements. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 08/03/2022 | LSHAMIS1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis, MBA; Lead Planner PROJECT: Thursday Pre-submittal meeting - T22PRE0160 Plaza Vega Address: 5151 N Oracle Rd Parcel(s): 10503034G Zoning: C-1 Existing Use: Shopping Center Proposed Use: Food Service, drive-thru TRANSMITTAL DATE: August 4, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. The Development Package and the related building permits can be reviewed concurrently; however, zoning will not approve the building permits until the Development Package is approved. 2. The site is zoned C-1 and the proposed use is food service which is permitted subject to use specific standards 4.9.4.M.1 and .5, and 4.9.13.O. 3. The parking ratio for food services is 1 space per 100 square feet of gross floor area plus outdoor seating area. Demonstrate that the entire site has sufficient parking to meet the minimum parking requirements per UDC 7.4.4. 4. Ensure all two-way Parking Area Access Lanes (PAAL) are a minimum of 24' wide. 5. Per UDC 7.4.7, the proposed use is required to have at three stacking spaces. 6. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov. |
| 08/03/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 08/03/2022 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: Plaza Vega Modification ACTIVITY NO. T22PRE0160 ADDRESS/PARCEL: 105-03-034G/F ZONING: C-1 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual - Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 08/03/2022 | LOREN MAKUS | ENGINEERING | REVIEW | Completed | 1. Revise crosswalk so it doesn't pass behind parking spaces. 2. Show adequate stacking so no backup onto Oracle will occur. 3. Provide enclosures for solid waste containers. Show access for service vehicles. 4. Include updated solid waste calculations. 5. Maximize water harvesting wherever new or revised landscaping is proposed. 6. Balanced basin detention and first flush retention must be provided for area of new development. Loren Makus loren.makus@tucsonaz.gov |
| 08/04/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 230 - 300 pm - T22PRE0160 - 5151 N ORACLE Site: Plaza Vega 1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience. 2. Vehicular access to this proposed project may or may not be impacted by Tucson Water's SR77-River Road to Calle Concordia CIP Project which is currently under construction. You may contact Mr. Walter Breitenstein, Tucson Water's Project Manager for this project, at for additional information about this CIP project. 3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |