Plan Number: T22PRE0150
Parcel: Unknown

Address: Unknown

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T22PRE0150
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2022 LOREN MAKUS ELECTRICAL ENGINEERING REVIEW Completed This site is currently within a FEMA Special Flood Hazard Area. Engineering is reviewing the materials supporting a CLOMR application.PDSD Engineering will not be requesting any special conditions for the Special Exception.

Loren Makus
loren.makus@tucsonaz.gov
07/19/2022 BILLIE LEE COMMENTS COMMENTS Active
07/19/2022 NMARTEL1 ZONING REVIEW Completed FROM: Nick Martell
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T22PRE0150
Address: 7655 S Kolb
Parcel(s): 1412204W
Existing Zoning: RH
Existing Use: Vacant
Proposed Use: Civic-Protective Services

TRANSMITTAL DATE: March 15, 2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Proposed use and use-specific standards: The proposed use is not listed as a permitted use in the UDC due to a clerical mistake in carrying over standards from the Land Use Code. The Civic-Protective Services use is allowed with one use specific standard: 4.9.13.F
3. Development standards: 30 ft building height (Scenic Corridor Zone)
4. Perimeter yard setbacks: Adjacent to residential zones = 4(H). Adjacent to non-residential zones = 0.
5. Applicable street setbacks: Kolb RD is a Major Street. MS&R setbacks are required as measured from the back of the future or existing curb.
6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445
7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698
8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov
9. Additional comments:
a. Please refer to the standards in the Approach Departure Corridor overlay in 5.6.8.B for the performance standards. Any variation from those standards will require a zoning examiner's special exception.
-No more than 20 employees per acre of site area at any time may be accommodated by intention, design, or in fact;
-The minimum project site area is five acres ; and,
-The maximum FAR is .30 of the project site area.
b. The site is in the ADC-2 overlay zone
c. The site is in the NCD-A overlay zone
d. The parcel is affected by the ERZ overlay zone
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at nicholas.martell@tucsonaz.gov.
07/19/2022 JPEELDA1 FIRE REVIEW Approved
07/19/2022 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active