Review Date Reviewer's Name Type of Review Description Status Comments
07/13/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Commonwealth Electric
ACTIVITY NO. T22PRE0
ADDRESS/PARCEL: 129-05-130R
ZONING: I-1

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

" A 10' minimum street landscape border is required along all public streets

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual - Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
07/13/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 200 - 230 pm - T22PRE0144 - 2111 E 17TH ST
Site: Commonwealth Electric

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
07/14/2022 DSTIFFE1 COT NON-DSD TRAFFIC Approved No Comments

David.Stiffey@tucsonaz.gov
07/14/2022 SAMUEL ROGERS ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Samuel Rogers, Planner

PROJECT: Thursday Pre-submittal meeting - T22PRE0144
Address: 2111 E 17th Street
Parcel(s): 129-05-130R
Zoning: I-1
Existing Use: Administrative and Professional Office
Proposed Use: Administrative and Professional Office

TRANSMITTAL DATE: 07/13/2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Provide an expansion calculation on the Development Package (DP). If the expansion is 25% or greater, the entire site will need to be brought up to code.
3. Parking will not be allowed in the ROW if an expansion greater than 25% is proposed.
4. The maximum height allowed is 75'.
5. The required setback is 0'.
6. There is no maximum lot coverage.
7. Long-Term Bicycle parking for the proposed Commercial Storage building is required at 1 space per 40,000 sq. ft. GFA. Minimum requirement is 2 spaces. Maximum requirement is 10 spaces.
8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at Samuel.Rogers@tucsonaz.gov or (520) 837-6932.
07/14/2022 JPEELDA1 COT NON-DSD FIRE Completed New building is 436 feet from the nearest hydrant and fire sprinklers shall be installed. Plans shall show fire sprinkler plans shall be submitted to TFD and a permit shall be obtained.
Gate shall be 20' wide and if electric a KNOX Key switch shall be provided along with a KNOX Box.

Question:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Tucson Fire Department
FirePlans Examiner
07/14/2022 SBLOOD1 ENGINEERING REVIEW Completed 1. The last approved site plan for this development I could find was T08CM03686 and so anything built or proposed after what was shown on that site plan needs to meet current development standards.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov