Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Plan Number: T22PRE0142
Parcel: Unknown

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T22PRE0142
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
07/06/2022 NMARTEL1 ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Nick Martell
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T22PRE0142
Address: 8646 E Tanque Verde RD
Parcel(s): 11449037D
Existing Zoning: SR
Proposed Zoning: R-2
Existing Use: Vacant
Proposed Use: Residential-Multifamily

TRANSMITTAL DATE: July 06, 2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Proposed use and use-specific standards: 4.9.7.B.6, .9, & .10
3. Development standards:
a. 25' Maximum Building Height
b. 75% Lot Coverage Maximum
4. Perimeter yard setbacks: Adjacent to RX-1, SR, and O-3 = 10' or ¾ the height.
5. Applicable street setbacks: Tanque Verde RD is a Major Street, and subject to a 21' setback from the back of the existing or future curb.
6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445
7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698
8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov
9. Additional comments:
a. Ensure any annexation conditions are met: https://www.tucsonaz.gov/pro/pdsd/permitdetail/C15-89-02/
b. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at nicholas.martell@tucsonaz.gov.
07/12/2022 BILLIE LEE COMMENTS COMMENTS Active
07/12/2022 ANY ELECTRICAL ENGINEERING REVIEW Active
07/12/2022 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
07/12/2022 JPEELDA1 FIRE REVIEW Reqs Change Dead end roads roads that exceed 150' shall be provided with a turn around.
Cul-De-Sac's shall be 96' in diameter
Fire access roads shall meet the COT road requirements.
Buildings may require fire sprinklers to be installed. Gates shall be have a KNOX key switch and KNOX box and shall have an unubstructed width of 20'.

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-033
Fire Plans Examiner
Tucson Fire Department