Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Plan Number: T22PRE0122
Parcel: Unknown

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T22PRE0122
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
06/14/2022 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
06/14/2022 BILLIE LEE COMMENTS COMMENTS Active
06/14/2022 JPEELDA1 FIRE REVIEW Completed You will have to provide a secondary access/exit and or provide fire department trun around options.

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@tucsonaz.gov
520-837-7033
Fire Plans Examiner
07/05/2022 NMARTEL1 ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Nick Martell
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T22PRE0122
Address: 1307 W Speedway
Parcel(s): 11612145A
Existing Zoning: 0-3
Proposed Zoning: C-1
Existing Use: Vacant
Proposed Use: Commercial-Food Service

TRANSMITTAL DATE: July 05, 2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Proposed use and use-specific standards: standard 4.9.4.M.1 & 5 and 4.9.13.O
3. Development standards:
a. 30' Maximum Building Height
b. No Lot Coverage Maximum
4. Perimeter yard setbacks: Adjacent to R-2 = 1 ½ H. Adjacent to O-3 zone = 0.
5. Applicable street setbacks: Speedway is a Major Street and is subject to a 21' setback as measured from the back of the existing or future curb.
6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445
7. Bike parking requirements: See UDC Article 7.4.8 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5698
8. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov
9. Additional comments:
a. A lot combination may be required to operate as one site.
10. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions please contact me at nicholas.martell@tucsonaz.gov.
07/06/2022 LOREN MAKUS ELECTRICAL ENGINEERING REVIEW Completed 1. Full floodplain analysis is required. Compliance with floodplain requlations will be required.
2. Site must meet commercial water harvesting requirements.
3. Site is in balanced basin. We will request critical basin detention and first-flush retention.
4. Solid waste configuration must meet requirements of TS 8-01.

Loren Makus
loren.makus@tucsonaz.gov