Plan Number: T22PRE0120
Parcel: Unknown

Address:
5849 S 6TH AV

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0120
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/08/2022 LOREN MAKUS ENGINEERING REVIEW Completed 1. A minor subdivision is allowed for this land division.

Loren Makus
loren.makus@tucsonaz.gov
06/08/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Minor subdivision
ACTIVITY NO. T22PRE0120
ADDRESS/PARCEL: 13810027B

7.7. Native Plant Preservation
The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survive.
A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. Please do not ask for an exception if there are native plants on site.

By far, the easiest way to meet this requirement is to set aside 30% of the lot for Natural Undisturbed Open Space (NUOS). Provide calculations and designate NUOS on the plans.


If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
06/09/2022 JPEELDA1 COT NON-DSD FIRE Completed Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
06/09/2022 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T22PRE0120 (Minor subdivision - 5849 S 6th Ave)

TRANSMITTAL DATE: 6/08/2022



This project will require a Minor Subdivision, information on the minor subdivision can be found here: https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pdf

Development must comply with administrative manual section 2-07



Here is a link to the submittal requirements: https://www.tucsonaz.gov/files/pdsd/forms/Submittal_Requirements.pdf



Ensure proposed lot lines do not encroach on existing building setbacks. Setbacks for the rear and side yard in an R-2 zone are 6’ or 2/3 * Height (whichever is greater). Setbacks are measured from structure to property line.



For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov / (520) 837-4082
06/09/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Reqs Change 300 - 330 pm - T22PRE0120
Minor Subdivision: 5849 S. 6th Avenue

1. It appears the first lot split into Parcels 1 and 2 have been completed, and you are now considering splitting Parcel 2. If that understanding is incorrect, please inform me of your intentions. The following comments are based on the assumption this understanding is correct.

2. Tucson Water's Remote Meter Policy requires that each new lot created by a lot split have a minimum of 15' of real property frontage onto an existing public water main. But as you've provided no dimensions for new Parcel 3, it is not possible for me to tell if the proposed layout complies with this policy.

3. As a practical matter, the narrow "flagpole" of proposed Parcel 3 must be wide enough for:
a) Vehicular access to and from the main body of proposed Parcel 3, and
b) All necessary underground utility service lines to be run from Sixth Avenue to the main body of proposed Parcel 3. At a minimum, a water service line and a house connection sewer line will need to be placed in this "flagpole", but be aware that additional utility service lines such as underground electric lines, telephone lines, cable TV lines, etc. may also need to be placed within this "flagpole." Each of these needs to be separated from others in both the vertical and the horizontal direction, so that they may be excavated and replaced or repaired as necessary without disturbing other service lines. The new water service line for proposed Parcel 3 will need to be 3' or more away from all property corners. Please contact Building Codes for the minimum horizontal and vertical separation distance between the water service line and the house connection sewer line.
Please consider both of these factors when determining the width of the "flagpole" for proposed Parcel 3. Tucson Water recommends that the "flagpole" of proposed Parcel 3 be 15' or more wide.

4. The above coments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
06/13/2022 SBEASLE1 COT NON-DSD TRAFFIC Needs Review