Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T22PRE0115
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/31/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | No Comments |
| 05/31/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 06/01/2022 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: Lohse YMCA ACTIVITY NO. T22PRE0115 ADDRESS/PARCEL: 60 W Alameda St ZONING: C-3 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. " A 10' minimum street landscape border is required along all public streets, however the project is within the Downtown Core Subdistrict of the Infill Incentive District, and the UDC landscape border requirements can be modified. " Maximize water harvesting in landscape areas If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 06/01/2022 | MGAYOSS1 | DESIGN PROFESSIONAL | REVIEW | Completed | Since this project includes exterior improvements that are visible from the right-of-way, and is located within the boundaries of the Infill Incentive District - Rio Nuevo Area (RNA) overlay zone, it will need to show compliance with the RNA standards specified in the Unified Development Code (UDC) Section 5.12.7, and go through the Design Review Board (DRB) for review. Because the site does not include historically-designated or eligible to be historically-designated structures, the project will not need to go through the Tucson-Pima Historical Commission's Plans Review Subcommittee (PRS) for review (UDC 5.12.7.F.4). Once you receive the first round of comments from the reviewers of the development package or construction documents, you will be able to proceed with the submittal of your Design Packet for review by the DRB. So these would be your next steps: 1. E-mail me the complete Design Packet, which should include the application form, plus all materials specified in the application form to demonstrate compliance with RNA and requirements; I will look at the design package and may require additional materials and may request clarifications; 2. Once Design Package is ready to be accepted, I'll give you instructions for payment of the $192.50 RNA review fees; 3. Once fees are paid, I will then schedule the meeting for review by the DRB. Once the DRB issues a recommendation to the PDSD Director, a Decision Notice on the Design Package will be issued. Please email me with any questions. Thanks. |
| 06/01/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 300 - 330 pm - T22PRE0115 - 60 W ALAMEDA ST Site: LOHSE YMCA. (Rio Nuevo Zone) 1. Tucson Water’s New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 06/02/2022 | LSHAMIS1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Loran Shamis, Lead Planner, MBA PROJECT: Thursday Pre-submittal meeting - T22PRE0115 Lohse YMCA Address: 60 W Alameda St Parcel(s): 117-11-001E Zoning: C-3 Overlays: Downtown Parking District; IID Downtown Core; Rio Nuevo and Downtown Zone Existing Use: Commercial Recreation Proposed Use: Commercial Recreation TRANSMITTAL DATE: June 2, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. The Development Package is a separate submittal from the building permits, and the building permits cannot be approved until the Development Package is approved. 2. Commercial Recreation is a permitted use in the C-3 zone. 3. This site is within the optional Infill Incentive District (IID) and some of the below requirements may be modified through opting into the IID (see Section 5.12). For more information contact Maria Gayosso at Maria.Gayosso@tucson.gov. 4. As this is within the Rio Nuevo boundaries, development must comply with Rio Nuevo Area (RNA) Zoning Design Standards (see Section 5.12.7) and a review through the Design Review Board (DRB) is required. 5. Setbacks a. East: 0' (nonres to nonres) b. South: The greater of 21' or the height of adjacent wall measured from the back of existing or future curb 6. Per Section 7.4.5.B.2.c, expansions that involve the removal of existing required bicycle spaces must relocate the removed spaces either on site or in conformance with the provisions UDC 7.4.5.B. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Loran.Shamis@tucsonaz.gov |
| 06/02/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | No comments Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |