06/28/2022 IMONSHI1 ZONING REVIEW Completed CDRC Thursday Pre-Submittal Transmittal
PDSD Zoning Review

FROM: Iman Monshizadeh, Planner

PROJECT: Pre-submittal meeting – T22PRE0101(2nd review)
Address: 116 N Cherry Av
Parcel(s): 124-09-1050
Zoning: R-2
Existing Use: Duplex
Proposed Use: Multifamily development

TRANSMITTAL DATE: 6/28/2022

COMMENTS:
1. All previous comments regarding development packages and submittal requirements apply.
2. Maximum residential density in the R-2 zone is 15 dwelling units per acre (Table 6.3-2.A). The site appears to be approximately 0.33 acres, allowing for a maximum of five dwelling units.
3. Maximum lot coverage for multifamily development in the R-2 zone is 75% (Table 6.3-2.A). Lot coverage calculations include storage areas and vehicle use areas. Lot coverage will need to be revised to ensure it is not exceeding 75%

4. Ensure parking spaces provided in garage meet minimum length and width requirements for parking, Section 7.4 UDC.
5. Setbacks for a non-residential use (multifamily) to a residential zone in an R-2 zone are 10’ or ¾ * Height (whichever is greater). Design Development Option (DDO) approval would be required prior to approval of the building permits. Setbacks for an established front perimeter yard are 20’ or one and one half times the height (Section 6.4.5.C.1). Depending on the height of the façade facing the front perimeter yard, setbacks might have to be revised.

If you have any questions, please contact me at Iman.monshizadeh@tucsonaz.gov
06/28/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Cherry Duplex
ACTIVITY NO. T22PRE0101v2
ADDRESS/PARCEL: 116 N Cherry Ave
ZONING: R-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

" A 10' minimum street landscape border is required along all public streets
" A minimum 10' interior landscape border is required adjacent to single-family residence. If an alley, minimum 20', separates the project from single-family, then this requirement does not apply. A DDO will be required to reduce the 10' interior border.

7.7. Native Plant Preservation
A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. Please note that Mesquite hybrids will be considered native trees and should be included in NPP inventory.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual - Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
06/28/2022 JPEELDA1 COT NON-DSD FIRE Completed As long as the drive to the East extend to the street we are ok with the project.

Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
Tucson Fire Department
Fire Plans Examinr
520-837-7033
06/29/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 300 - 330 pm - T22PRE0101 (a 2nd review)
Site: Cherry Duplex

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
06/29/2022 SBLOOD1 ENGINEERING REVIEW Completed 1. The site is in a balanced basin. Balanced basin detention and first flush retention are required. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With edits to the manual found: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf
2. Maximize water harvesting.

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov
06/29/2022 DSTIFFE1 COT NON-DSD TRAFFIC Reqs Change T22PRE0101 (2nd Review)
Comments:
1. Label on the plan where Cherry Avenue is.
2. Label on the plan where Right of Way is, and the ROW width from centerline of Cherry Ave.
3. The driveway entrance to the property must be a P.A.G. standard 206 driveway apron. Driveway aprons do not have curb returns.
4. Maximum curb-cut length is 20 Ft. and a minimum of 4 Ft from the end of the curb return at an alley. (the current plan shows 25' 1".)
5. New 5 Ft wide concrete sidewalk is required in the ROW, along the entire property frontage.
6. New concrete curb per P.A.G. standard 209.
7. 3' minimum buffer between curb and sidewalk, unless ROW is limited.

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov