Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T22PRE0098
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/17/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | T22PRE0098 Comments: 1. No Comments David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 05/18/2022 | WBERGER1 | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Wyatt Berger, Planner PROJECT: Thursday Pre-submittal meeting - T22PRE0098 Address: 1202 W Irvington Rd Parcel(s): 137-05-5500 Zoning: PAD-29 "Irvington Commercial Center" Existing Use: Food Service Proposed Use: Food Service TRANSMITTAL DATE: May 18, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. A revision of DP16-0044 is acceptable. Building permits may be submitted currently with the DP; however, the DP must be approved prior to the approval of the associated building permits. 2. Food Service is a permitted land use, subject to UDC use-specific standards 4.9.4.M.1 and 4.9.13.P. 3. Three motor vehicle stacking spaces are required (Table 7.4.7-1). Ensure all stacking design criteria within 7.4.7.B are met. 4. Demonstrate how the proposed construction complies with the parking tables within DP16-0044, as you are proposing the removal of spaces. 5. Short-term bicycle parking is required at 1 space per 2,000 sq. ft. gfa; minimum requirement is 2 spaces. 6. Long-term bicycle parking is required at 1 space per 12,000 sq. ft. gfa; minimum requirement is 2 spaces. 7. Demonstrate that the ADA parking spaces provided are meeting required widths. For ADA van accessibility, either an 11-foot-wide parking space, or an eight-foot-wide parking space in combination with an eight-foot-wide adjacent access lane, is required. 8. Pedestrian paths providing access to main building entrances shall have an unobstructed width of at least 6 feet. 9. Ensure access standards found in Section 7.8 of the UDC and Sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. 10. Pedestrian paths cannot cross a stacking area. A Technical Standards Modification Request (TSMR) may be applicable. 11. Prior to the submittal of a development package, the developer must procure a letter of recommendation from the PAD's Architectural Review Committee. 12. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at Wyatt.Berger@tucsonaz.gov. |
| 05/18/2022 | AWARNER1 | LANDSCAPE | REVIEW | Passed | |
| 05/18/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T22PRE0098 - 1202 W IRVINGTON RD Site: Chipotle Mexican Grill 1. Tucson Water's New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 05/19/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | Address shall be the complete address 1202 W Irvington posted near the roof in 15" letters and numbers in contrasting colors Any fire permits ie: kitchen fire suppression system, fire sprinkler, fire alarm and or BulkCO2 come directly to TFD TFD included with the building permit for fire review of the building not the fire systems Plan review for fire is about 2 weeks behind the 21 days Questions: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 05/19/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. The pedestrian circulation path can't be crossing the drive-thru stacking lane. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |