Plan Number: T22PRE0092
Parcel: Unknown

Review Status: Active

Review Details: PREAPPLICATION MEETING

Plan Number - T22PRE0092
Review Name: PREAPPLICATION MEETING
Review Status: Active
Review Date Reviewer's Name Type of Review Description Status Comments
05/10/2022 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Active
05/10/2022 BILLIE LEE COMMENTS COMMENTS Active
05/10/2022 ANY ELECTRICAL ENGINEERING REVIEW Active
05/11/2022 NMARTEL1 ZONING REVIEW Completed Rezoning Pre-Submittal Transmittal

FROM: Nicholas Martell
PDSD Zoning Review

PROJECT: Rezoning Pre-submittal meeting T22PRE0092
Address: 8800 E Jacaranda Way
Parcel(s): 114-51-228C
Existing Zoning: SR
Proposed Zoning: RX-1, R-1
Existing Use: Residential
Proposed Use: Single-Family Residential

TRANSMITTAL DATE: May 11, 2022

COMMENTS:
1. Development must comply with the Administrative Manual Section 2-06 - Development Package.
2. Proposed use and use-specific standards: RX-1; 4.9.7.B.6, .8, & .9(Single-Family, Detached) R-1: For 1 unit, 4.9.7.B.5 - 9; for 2 units (min. 10,000 sf lot size required), 4.9.7.B.1 - .9, & .11
3. Development standards:
a. RX-1 Height: 30'
b. R-1 Height: 25'
c. Minimum Lot size R-1: 7,000 Sq ft.
d. Minimum Lot Size RX-1: 36,000 Sq ft.
e. All lots are eligible for accessory dwelling units.
4. Perimeter yard setbacks:
a. R-1: 6' or 2/3(H)
b. RX-1: 20'
5. Applicable street setbacks: See 6.4.5.C for street perimeter yard setbacks.
6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445
7. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov
8. Additional comments:
a. For any proposed roads, ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met.
b. Ensure adherence to annexation conditions C9-84-32. There may be agreements and notifications required for development in the area.
9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards.

If you have any questions, please contact me at nicholas.martell@tucsonaz.gov.
05/11/2022 JPEELDA1 FIRE REVIEW Completed Development will probably require new fire hydrants to be installed. Multi family will require fire sprinklers to be installed.

Jennifer Peel-Davis
Fire Plans Examiner
520-837-7033
Jennifer.Peel-Davis@Tucsonaz.gov