Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Plan Review Detail
Review Status: Active
Review Details: PREAPPLICATION MEETING
Plan Number - T22PRE0092
Review Name: PREAPPLICATION MEETING
Review Status: Active
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2022 | JOHN BEALL | M&C Public Hearing 4 Plan Amendment | Set M&C Public Hearing Date | Active | |
| 05/10/2022 | BILLIE LEE | COMMENTS | COMMENTS | Active | |
| 05/10/2022 | ANY | ELECTRICAL ENGINEERING | REVIEW | Active | |
| 05/11/2022 | NMARTEL1 | ZONING | REVIEW | Completed | Rezoning Pre-Submittal Transmittal FROM: Nicholas Martell PDSD Zoning Review PROJECT: Rezoning Pre-submittal meeting T22PRE0092 Address: 8800 E Jacaranda Way Parcel(s): 114-51-228C Existing Zoning: SR Proposed Zoning: RX-1, R-1 Existing Use: Residential Proposed Use: Single-Family Residential TRANSMITTAL DATE: May 11, 2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. Proposed use and use-specific standards: RX-1; 4.9.7.B.6, .8, & .9(Single-Family, Detached) R-1: For 1 unit, 4.9.7.B.5 - 9; for 2 units (min. 10,000 sf lot size required), 4.9.7.B.1 - .9, & .11 3. Development standards: a. RX-1 Height: 30' b. R-1 Height: 25' c. Minimum Lot size R-1: 7,000 Sq ft. d. Minimum Lot Size RX-1: 36,000 Sq ft. e. All lots are eligible for accessory dwelling units. 4. Perimeter yard setbacks: a. R-1: 6' or 2/3(H) b. RX-1: 20' 5. Applicable street setbacks: See 6.4.5.C for street perimeter yard setbacks. 6. Parking requirements: See UDC Article 7.4.4 https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5445 7. Landscape requirements can be discussed further with Anne Warner at Anne.Warner@tucsonaz.gov 8. Additional comments: a. For any proposed roads, ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. b. Ensure adherence to annexation conditions C9-84-32. There may be agreements and notifications required for development in the area. 9. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions, please contact me at nicholas.martell@tucsonaz.gov. |
| 05/11/2022 | JPEELDA1 | FIRE | REVIEW | Completed | Development will probably require new fire hydrants to be installed. Multi family will require fire sprinklers to be installed. Jennifer Peel-Davis Fire Plans Examiner 520-837-7033 Jennifer.Peel-Davis@Tucsonaz.gov |