Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T22PRE0089
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/09/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | T22PRE0089 Comments: 1. New 5 Ft wide sidewalk along the entire property frontage 2. New concrete curb per P.A.G. standard 209 3. New P.A.G. standard 206 driveway aprons 4. Curb cuts are 10 Ft. minimum and 20 Ft. maximum 5. Close any existing curb cuts that will not be used 6. A sidewalk is required to connect the onsite pedestrian circulation path to the right of way. If the units are separated by a wall, a sidewalk/ ROW connection will be required for each unit 7. Where adjoining sidewalk from the property ties to sidewalk along the ROW frontage, a 60" X 60" ADA landing is required (this at curb returns or a type 1 curb access ramp) (60" X 6" Landing not to exceed 2% cross slope in all directions.) 8. 3' minimum buffer between curb and sidewalk, unless ROW is limited David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 05/10/2022 | SAMUEL ROGERS | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Samuel Rogers; Planner PROJECT: Thursday Pre-submittal meeting - T22PRE0089 Address: 3720/3730/3736 N Fairview Av Parcel(s): 106-05-112F Zoning: R-3 Existing Use: Vacant Proposed Use: Minor Subdivision TRANSMITTAL DATE: 05/12/2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-07.0.0: Final Plat, Block Plat, Minor Subdivision, and Condominium Plat Applications. 2. If the owner elects to split the lot into two parcels a Minor Subdivision will still be required, the site is in an existing subdivision and had previously been split. 3. N Fairview Av is a Major Street and Route (MS&R), the street side will need to comply with MS&R setbacks. MS&R setbacks are determined by the ADT of the road, see table 6.4.5.C-1 (https://codelibrary.amlegal.com/codes/tucson/latest/tucson_az_udc/0-0-0-5192) 4. N Fairview Av is proposed to be widened, reach out to the Department of Transportation and Mobility to see if this road is planned to actually be widened. You will need to either comply with the widening, or submit a supplemental site showing how the site will comply with the widening if it occurs. 5. Once the Minor Subdivision is approved by Mayor and Council, the building permits will be able to be approved. 6. The proposal is adequate to proceed with submittal of a Minor Subdivision application. 7. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Minor Subdivision review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. If you have any questions please contact me at samuel.rogers@tucsonaz.gov or (520) 837-6932. |
| 05/10/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T22PRE0089 - 3720 N FAIRVIEW Minor Subdivision - Fairview Casitas 1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience. 2. Each of the new single family residentials lots will need its own water meter. 3. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 05/11/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | In order for the houses not to have fire sprinklers all houses to the furthest part of the house shall not exceed 600'. That is as the hose lays not the crow flies. As long as this requirement is met you will not need to install a fire hydrant and or install fire sprinklers. Jennifer Peel-Davis Fire Plans Examiner 520-837-7033 Jennifer.Peel-Davis@Tucsonaz.gov |
| 05/12/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. No retention/detention required. 2. Maximize water harvesting with landscaping depressed 9". Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |
| 05/12/2022 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: Fairview Casitas ACTIVITY NO. T22PRE0089 ADDRESS/PARCEL: 106-05-122F ZONING: R-3 7.7. Native Plant Preservation The NPPO is intended to encourage preservation in place of healthy native plants through sensitive site design that minimizes the disruption of areas within the site containing healthy plants while allowing for salvage and transplanting plants on the site that are likely to survive. A Native Plant Preservation Plan, Section 7.7.4, is required to be submitted and approved or a request for an exception from the Native Plant Preservation requirements approved in accordance with Sections 7.7.3.D.3 & .4 of the Unified Development Code (UDC) and Admin. Manual Section 2-11.0.0 prior to Grading Plan approval. Please note that Mesquite hybrids will be considered native trees and should be included in NPP inventory. By far, the easiest way to meet this requirement is to set aside 30% of the lot for Natural Undisturbed Open Space (NUOS). If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 05/12/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Show on-site maneuverability. |