Plan Number: T22PRE0074
Parcel: Unknown

Address:
1501 E METRIC PL

Review Status: Completed

Review Details: PREAPPLICATION MEETING

Plan Number - T22PRE0074
Review Name: PREAPPLICATION MEETING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/05/2022 JPEELDA1 FIRE REVIEW Completed If you have any fire questions please contact me:

Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Fire Plans Examiner
04/12/2022 BILLIE LEE COMMENTS COMMENTS Passed
04/12/2022 PMCLAUG1 ELECTRICAL ENGINEERING REVIEW Passed
04/13/2022 NICHOLAS ROSS ZONING REVIEW Completed Pre-Submittal

To: Planning and Development Service Department, Entitlements Section
From: Nick Ross

132-13-0260
I-1 (Special Exception)
T22PRE0074
Zoning Examiner Special Exception Procedure

Transmittal Date: April 13, 2022

The proposed utilities use falls under UDC Article 4.8-5, Table 4.8-1: Permitted Uses -Industrial Zones. Commercial Services Land Use Group with Land Use Class/Type: Wireless Communication subject to Use Specific Standards 4.9.13.Q and 4.9.4.I.2,.3, & 6.b. Any variation to the Use Specific Standards should be addressed through the Special Exception process.

Development Standards: Setbacks are 2H of proposed tower (See Use Specific Standards).
Use Specific Standards: 4.9.4.I.2, 3 & 6.b
Vehicular Access: Vehicular access appears to be adequate
Vehicle Parking Required: 2 spaces
Vehicle Parking Provided: Not provided
Short Term Bicycle Required: None
Short Term Bicycle Provided: None
Long Term Bicycle Required: None
Long Term Bicycle Provided: None
Off-Street Loading Required: None
Off-Street Loading Provided: None
Pedestrian Access: Pedestrian access appears to be adequate
Allowed Building Height: 300 ft (Communications)
Proposed Building Height: 80ft.

Should you have questions, contact me at Nicholas.ross@tucsonaz.gov
09/12/2022 JOHN BEALL M&C Public Hearing 4 Plan Amendment Set M&C Public Hearing Date Completed PROJECT DESCRIPTION & LOCATION:
The proposed project area is just northwest of the intersection of E Ajo Way and Interstate-10, in Ward 5. It consists of the construction of a new wireless communication facility with an 80-foot monopole tower and a 12-foot access easement. No generator is proposed. The land is owned by Caprio Partners LLC and is zoned I-1 Industrial. The subject area is covered by the Kino Area Plan, and Plan Tucson. The maximum allowed height for a cellular communications tower in the I-1 zone is 80-feet. This proposal will require a Zoning Examiner Special Exception review per the Unified Development Code (UDC) Section 4.9.4.I.6.b. because it is a new tower.

APPLICANT NAME: Eric Hurley
PHONE: 480-688-1393 E-MAIL ERIC.HURLEY@PINNACLECO.NET


Plan Amendment

0 YES 1 X NO 0 TO BE CONFIRMED LATER

PLAN SUPPORT BASED ON CONCEPT PRESENTED (SEE NOTES BELOW):

0 YES 0 NO 1 X WILL DEPEND ON DESIGN

1 DESIGN COMPATIBILITY + COMMUNITY INPUT 0 ENVIRONMENTAL RESOURCE REPORT

PLAN DIRECTION

ADOPTED PLAN(S): Plan Tucson (PT) and Kino Area Plan
PLAN AMENDMENT NOT REQUIRED BASED ON CONCEPT PRESENTED (SEE NOTES BELOW)


APPLICABLE PLAN POLICIES: Plan Tucson
Plan policy is provided by Plan Tucson, which contains a variety of elements that are categorized in four focus areas, including the Social Environment, the Economic Environment, the Natural Environment and the Built Environment. Each focus area contains specific goals, and each element contains specific policies. Plan Tucson includes the following stipulations for telecommunications facilities:
LT28.4.10 Require telecommunications facilities be located, installed, and maintained to minimize visual impact and preserve views. Cabling and fiber optics should be installed underground where possible, and the visual impact of cellular towers should be a prime consideration in the City's acceptance and approval.
LT28.4.11 Improve the appearance of above-ground utilities and structures and extend access to high-tech wireless communications facilities throughout the City.
LT.28.3.14 Support environmentally sensitive design that protects the integrity of existing neighborhoods, complements adjacent land uses, and enhances the overall function and visual quality of the street, adjacent properties, and the community.

Kino Area Plan
The proposed tower is not located within any of the residential, industrial, commercial, public or semi-public specific sites identified in the Kino Area Plan. The plan has no specific policy direction regarding wireless communication facilities.

SURROUNDING ZONING AND USES:
The site is zoned I-1 Light Industrial, and located on the north side of Metric Place, which is near the intersection of Interstate-10 and E Ajo Way at Exit 263A. This portion of E Ajo Way is classified as an Arterial Street on the City of Tucson Major Streets and Routes Map.

Surrounding properties to the north, south, east and west area also zoned I-1 Light Industrial. This includes the right of way for Interstate-10, which is zoned both I-1 and PAD-15. Across the I-10 right of way is the Tucson Marketplace development, which is also zoned PAD-15. Other surrounding land uses include a tire and auto center to the southeast, self-storage units to the south, and embroidery, contract sewing, and air conditioning repair to the to the west.


ANALYSIS:
This special exception is for a request to construct a wireless communication facility in the I-1 Industrial zone. The proposed facility includes an 80'-0" monopole tower, on a 4' by 12' concrete pad, with a 20' by 40' by 6' tall CMU wall. The proposed tower would also include an outdoor power cabinet, outdoor RF cabinet, a GPS antenna, and underground three 4" underground conduits. The maximum permitted height for a new tower permitted by a Zoning Examiners Special Exception is 80'-0" from grade. If the tower is any taller than that, then a lengthier and more complex Mayor and Council Special Exception process will be triggered.

Per Section 4.9.4.I.6.b of the UDC, the maximum tower height permitted by Zoning Examiner Special Exception is 80 feet. Additionally, the tower must be set back at least two times the height of the structure from the boundary of any property zoned residential or office. The nearest residential of office zone is approximately 875-feet from the proposed tower location.

The development plan shows co-locating opportunities below the top hat of the proposed tower, which addresses the negative proliferation requirement of the UDC.

An RF Coverage Map will need to be provided with the application submittal, along with a statement that the applicant has investigated verticality in the area, and there are not suitable towers on which to co-locate. Additionally, the cabling inside of the monopole shown in the plan should remain, and no foot pegs should be showing to give the monopole a smoother look.
Based on the standards listed above from both Plan Tucson, and the Kino Area Plan, No Plan Amendment is required.