Plan Review Detail
Review Status: Completed
Review Details: PREAPPLICATION LABELS
Plan Number - T22PRE0069
Review Name: PREAPPLICATION LABELS
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/05/2022 | JPEELDA1 | COT NON-DSD | FIRE | Completed | Building shall comply with IFC 2018, Section 507.5 or fire sprinklers shall be installed. Provide diagram on plans of hose lay as the hose lays not the crow flies. If you have any fire questions please contact me: Jennifer Peel-Davis Jennifer.Peel-Davis@Tucsonaz.gov 520-837-7033 Fire Plans Examiner |
| 04/12/2022 | DSTIFFE1 | COT NON-DSD | TRAFFIC | Completed | T22PRE0069 Comments: 1. New concrete driveway aprons per P.A.G. standard 206. 2. Existing curb cuts can be used. 3. New Sidewalk- 6 Ft wide with 3' wide buffer between back of curb and sidewalk. 4. New concrete curb per P.A.G. standard 209. 5. IMPORTANT- Call inspector for precon to discuss necessary field fit driveway's/ sidewalk. David Stiffey DTM Project Coordinator David.Stiffey@tucsonaz.gov |
| 04/13/2022 | AWARNER1 | LANDSCAPE | REVIEW | Completed | CDRC TRANSMITTAL PROJECT: Aztec Transmission ACTIVITY NO. T22PRE0069 ADDRESS/PARCEL: 770 W Grant Rd ZONING: C-2 7.6 Landscaping and Screening The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10. • Trees will be required to be placed within the parking areas • A 10’ minimum street landscape border is required along all public streets Placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40’ of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself to provide shade on asphalt. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a. Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design. Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf If you have any questions about this transmittal, contact Anne Warner, RLA PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov |
| 04/13/2022 | SBEASLE1 | TUCSON WATER NEW AREA DEVELOPMENT | REVIEW | Completed | 130 - 200 pm - T22PRE0069 - 770 W GRANT RD - Site: Aztec Transmission 1. Tucson Water's New Area Development Unit has no objections to the proposed development. 2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to: Tim Rowe, P.E., Civil Engineer Tucson Water, New Development Section 201 N. Stone Avenue, #2-220 P.O. Box 27210 Tucson, AZ 85726-7210 (520) 837-2106 tim.rowe@tucsonaz.gov |
| 04/14/2022 | PAUL CAMARENA | ZONING | REVIEW | Completed | CDRC Thursday Pre-Submittal Transmittal PDSD Zoning Review FROM: Paul Camarena, Planner PROJECT: Thursday Pre-submittal meeting – T22PRE0069 Address: 770 W Grant Rd Parcel(s): 107083180 Zoning: C-2 Existing Use: Automotive - Service and Repair, Major. Proposed Use: Automotive - Service and Repair, Major. TRANSMITTAL DATE: 04/13/2022 COMMENTS: 1. Development must comply with the Administrative Manual Section 2-06 - Development Package. 2. The use is Automotive - Service and Repair, Major, which is permitted in the C-2 zone. The development is subject to use specific standards C-2: 4.9.13.E 3. Vehicular parking requirements are 1 space per 300 sq. ft. GFA, 12 spaces are required with 1 being an accessible parking space a. A cross-access parking agreement with 780 W Grant can be made to help with the required parking. 4. Bicycle Parking requirements are 2 short term parking spaces and 2 long term spaces required 5. The minimum width of a two-way PAAL is 24 ft. a. Angled parking may be an option if PAAL minimum width is met. 6. Ensure access standards found in section 7.8 of the UDC and sections 7-01.0.0 and 10-01.0.0 of the Technical Standards Manual are met. Pedestrian access along the street is required. Show complete pedestrian circulation for the site. Grant does not have a sidewalk. a. A pedestrian refuge area is required for the new storage building. b. The pathway from the Accessible parking space to the front door needs to be a sidewalk. Sidewalks associated with PAALs must be physically separated from any vehicular travel lane by means of curbing, grade separation (minimum six inches), barriers, railings, or other means 7. Permit T07CM04213 was withdrawn, The storage and the addition never got permitted. This expansion will require the entire site to be up to code. 8. The comments provided are preliminary and are not to be assumed as a complete review of the proposal. During the Development Package review process, a full review will be made by Zoning to assure compliance with the applicable UDC development criteria and Technical Standards. 9. Link for historic documentation https://www.tucsonaz.gov/pro/pdsd/permitdetail/H000013150/107083180 If you have any questions, please contact me at Paul.Camarena@tucsonaz.gov |
| 04/14/2022 | SBLOOD1 | ENGINEERING | REVIEW | Completed | 1. Maximize water harvesting in new landscaped areas. 2. APC trash pickup in the alley is fine as long as you show that the waste stream calculations support APC and that the alley is passable for the collection vehicle the entire length of the alley. Stephen Blood (520) 837-4958 Stephen.blood@tucsonaz.gov |