Plan Number: T22PRE0067
Parcel: Unknown

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0067
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
03/30/2022 JPEELDA1 COT NON-DSD FIRE Completed New building might require fire sprinklers please contact me so that we can discuss the size, type of construction, hydrant requirements and so on.

Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
04/13/2022 AWARNER1 LANDSCAPE REVIEW Passed
04/13/2022 DSTIFFE1 COT NON-DSD TRAFFIC Completed T22PRE0067
Comments:

No Comments.


David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
04/13/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 230 - 300 pm - T22PRE0067 - 4433 E BERMUDA ST - Minor Subdivision/ Block Plat: Divide one lot into two lots

1. Tucson Water's New Area Development Unit has no objections to the proposed development and offers the following comments for your convenience.

2. Each of the two proposed lots must have its own water service line. Due to the limited capacity of the existing 3" cement asbestos water main on the north side of the property, only one of these parcels may be served by that 3" water main. The other parcel will need to be served by the existing 6" cement asbestos water main in Bermuda St.

3. The existing ¾" copper water service line that currently serves the existing single story residence on the property may be used to serve Parcel 2, but it may not also serve Parcel 1. This existing water service was installed in 1960, and replacement of this existing water service line is highly recommended, when a new building is constructed on Parcel 2.

4. A new water service line will be required to serve the existing single story residence on the property in Parcel 1. It must be located entirely within Parcel 1 and the adjacent rights of way. No portion of it may lie on Parcel 2.

5. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
04/14/2022 SBEASLE1 ZONING REVIEW Completed
04/14/2022 SBLOOD1 ENGINEERING REVIEW Completed No comments

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov