Plan Number: T22PRE0060
Parcel: Unknown

Address:
1131 N 6TH AV

Review Status: Completed

Review Details: PREAPPLICATION LABELS

Plan Number - T22PRE0060
Review Name: PREAPPLICATION LABELS
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
04/25/2022 JPEELDA1 COT NON-DSD FIRE Completed Questions:
Jennifer Peel-Davis
Jennifer.Peel-Davis@Tucsonaz.gov
520-837-7033
Fire Plans Examiner
05/04/2022 IMONSHI1 ZONING REVIEW Completed FROM: Iman Monshizadeh

PDSD Zoning Review Section



PROJECT: T22PRE0060 (1131 N 6th Ave) – Montessori Middle School)

TRANSMITTAL DATE: 5/03/2022

Provide proof via documentation that the school is a charter school. If these documents are provided then the project can be exempt from certain zoning requirments. Provide these documents to Nicholas.ross@tucsonaz.gov or to Elisa.Hamblin@tucsonaz.gov

This project will require a development package, Information on the Development package can be found at: https://www.tucsonaz.gov/files/pdsd/forms/Development_Package_and_Land_Division-Subdivision_Application.pd

Proposed use is Educational Use: Elementary and Secondary. Use specific standards 4.9.3.D 1-7 apply, 4.9.3.D.1.2.b does not apply per letter.

Eastern setback is 21’ or the Height measured from structure to back of existing/future curb.

Change of use with additional parking requirements requires the entire site to be brought up to code.

Parking calculations are calculated individually, only 5 spaces are required.

Full vehicle maneuverability will be required on site for the parking lot. Backing out into a Right of way is not permitted. Access from an alley to a commercial project is not permitted. 7.4.6 UDC.

Aside from the demolition of the structure which may or may not be older than 50 years, historic review will not be required with the City of Tucson

If the lot to the south is combined, both properties will need to be brought up to code. If both parcels are operating as one site, both sites will have to be brought up to code.

All required parking must be located on site and meet maneuverability requirements of section 7.4 of the UDC

Alley can be purchased through real estate section of the Department of Transportation and Mobility. This may be an option to help meet parking requirements and standards.





For questions regarding Zoning comments, please contact me at: Iman.Monshizadeh@tucsonaz.gov / (520) 837-4082
05/04/2022 AWARNER1 LANDSCAPE REVIEW Completed CDRC TRANSMITTAL

PROJECT: Montessori Middle School
ACTIVITY NO. T22PRE0060
ADDRESS/PARCEL: 1131 N 6th Ave
ZONING: C-2

7.6 Landscaping and Screening
The Unified Development Code (UDC) requires all new development or an expansion of greater than 25% of an existing development submit a landscape plan, UDC 7.6.2. Preparation of the landscape plan shall adhere to UDC 7.6.4. and Administrative Manual 2-10.

• A 10’ minimum street landscape border is required along all public streets
• Minimum 10’ Interior landscape borders are required adjacent to any single-multi family use, regardless of zoning

Placing trees along the edge of a parking area or at the ends of parking row does not meet the intent of the UDC. All spaces within 40’ of a tree is only one of the requirements. The intent is to provide as much shade on the asphalt as possible, and the requirement is 1 tree per 4 parking spaces; trees are expected to be placed within the parking area itself to provide shade on asphalt. Trees are to be distributed evenly throughout the parking area, UDC 7.6.4.1.B.1, UDC Technical Standards Manual 5-01-.3.2 and UDC 7.6.4.B.1.a.

A DDO will be required to deviate from any of these standards.

Commercial Rainwater Harvesting plan is required UDC Technical Standards Manual – Section 4-01.0.0. and Section 5-01.0.0 Landscaping and Screening
Adherence to the Low Impact Development Standards outlined in Section 5 of the PCRFCD Design Standards for Stormwater Detention and Retention is required and shall work in conjunction with the Commercial Rainwater Harvesting design.
Using Low Impact Development design and water harvesting provides critical basin detention and first flush retention for all new development and impervious area. The newly adopted Detention/Retention Manual can be found: https://webcms.pima.gov/UserFiles/Servers/Server_6/File/Government/Flood%20Control/Rules%20and%20Procedures/Stormwater%20Detention-Retention/dssdr-final-201406-manual.pdf

With CoT edits to the manual are found at: https://www.tucsonaz.gov/files/pdsd/codes/Detention_Retention_Manual_Tech_Standards_Amemdments.pdf

If you have any questions about this transmittal, contact Anne Warner, RLA
PDSD Landscape/NPPO Review at email anne.warner@tucsonaz.gov
05/04/2022 SBEASLE1 TUCSON WATER NEW AREA DEVELOPMENT REVIEW Completed 300 - 330 pm - T22PRE0060
Site - Montessori Middle School

1. Tucson Water's New Area Development Unit has no objections to the proposed development.

2. The above comments are based on the limited preliminary information provided by the applicant and should not be construed as a complete review of the proposal. Any questions, comments or concerns about these comments may be directed to:

Tim Rowe, P.E., Civil Engineer
Tucson Water, New Development Section
201 N. Stone Avenue, #2-220
P.O. Box 27210
Tucson, AZ 85726-7210
(520) 837-2106
tim.rowe@tucsonaz.gov
05/04/2022 DSTIFFE1 COT NON-DSD TRAFFIC Completed T22PRE0060
Comments:
1. No Comments

David Stiffey
DTM Project Coordinator
David.Stiffey@tucsonaz.gov
05/05/2022 SBLOOD1 ENGINEERING REVIEW Completed No comments

Stephen Blood
(520) 837-4958
Stephen.blood@tucsonaz.gov